Quarter wave transformer calculator for RF matching: section impedance, length on microstrip, coax or air line, trace width, VSWR bandwidth, multi-section steps and reactive loads.
Enter the input and load impedance, the frequency and the line type to get the transformer impedance and its length.
Complex Load & VSWR Limit
Transformer Layout
| Line | Impedance | Trace Width | Electrical Length | Physical Length |
|---|---|---|---|---|
| Quarter-Wave Section | 70.71 Ω | 62.8 mil | 90.00° | 0.6901 in |
VSWR Plot & Smith Chart
Frequency Sweep Table
| Frequency | Section Angle | Input Impedance | VSWR | Return Loss |
|---|---|---|---|---|
| 1.200 GHz | 45.00° | 66.67 - j23.57 Ω | 1.64:1 | 12.30 dB |
| 1.680 GHz | 63.00° | 55.74 - j15.94 Ω | 1.38:1 | 16.00 dB |
| 1.920 GHz | 72.00° | 52.51 - j10.91 Ω | 1.24:1 | 19.28 dB |
| 2.160 GHz | 81.00° | 50.62 - j5.530 Ω | 1.12:1 | 25.16 dB |
| 2.280 GHz | 85.50° | 50.15 - j2.774 Ω | 1.06:1 | 31.14 dB |
| 2.400 GHz · Center | 90.00° | 50.00 Ω | 1.00:1 | Over 60 dB |
| 2.520 GHz | 94.50° | 50.15 + j2.774 Ω | 1.06:1 | 31.14 dB |
| 2.640 GHz | 99.00° | 50.62 + j5.530 Ω | 1.12:1 | 25.16 dB |
| 2.880 GHz | 108.0° | 52.51 + j10.91 Ω | 1.24:1 | 19.28 dB |
| 3.120 GHz | 117.0° | 55.74 + j15.94 Ω | 1.38:1 | 16.00 dB |
| 3.600 GHz | 135.0° | 66.67 + j23.57 Ω | 1.64:1 | 12.30 dB |
Step-by-Step Math
Geometric Mean Rule Behind the Quarter Wave Transformer Calculator
A 50 Ω source matches a 100 Ω load through a 70.71 Ω line that is one quarter wavelength long. The section impedance is the geometric mean of the two, the square root of 50 x 100.
Here Zt is the characteristic impedance of the quarter-wave section, Zin is the impedance it must present at its input, and ZL is the resistive load at its far end. All three are in ohms.
The match works because a quarter-wave line inverts impedance. Whatever load sits at its end, the input sees Zt2 / ZL, so a 70.71 Ω line turns 100 Ω into 5,000 / 100 = 50 Ω, as Jim Stiles of the University of Kansas derives it.
This form is the reverse quarter wave transformer calculator check for a line you already have. A 75 Ω quarter-wave coax ending in 100 Ω presents 56.25 Ω, a 1.13:1 VSWR on a 50 Ω system rather than a perfect match.
The section must be a quarter of the guided wavelength, not the free-space wavelength. Every quarter wave transformer calculator length therefore depends on the line's velocity factor, which the next section sets out for common lines.
Section Length on Microstrip, Coax and Air Line
At 2.4 GHz a 70.71 Ω quarter-wave section is 17.53 mm long on 1.57 mm (62 mil) FR-4 microstrip, 20.61 mm in solid polyethylene coax and 31.23 mm in air. The difference in each quarter wave transformer calculator length is the velocity factor.
L is the physical section length, c is the speed of light (299.792458 m/µs, so c / f in MHz gives meters), VF is the velocity factor and f is the frequency. For a dielectric-filled line VF is 1 / the square root of the effective permittivity.
| Line at 2.4 GHz, 70.71 Ω | Velocity factor | Quarter-wave length | Trace width on 62 mil |
|---|---|---|---|
| FR-4 microstrip (εr 4.4) | 0.561 | 17.53 mm (0.690 in) | 62.8 mil (1.60 mm) |
| RO4350B microstrip (εr 3.66) | 0.605 | 18.90 mm (0.744 in) | 73.8 mil (1.87 mm) |
| PTFE microstrip (εr 2.2) | 0.742 | 23.18 mm (0.913 in) | 109.6 mil (2.78 mm) |
| Solid PE coax | 0.66 | 20.61 mm (0.811 in) | Not a trace |
| PTFE coax | 0.695 | 21.70 mm (0.855 in) | Not a trace |
| LMR-400 foam coax | 0.84 | 26.23 mm (1.033 in) | Not a trace |
| Air line | 1.00 | 31.23 mm (1.230 in) | Not a trace |
Microstrip widths and effective permittivity in a quarter wave transformer calculator come from the Wheeler and Hammerstad closed forms for thin copper.
On 62 mil FR-4 the 70.71 Ω section is 62.8 mil wide, between the 118.5 mil 50 Ω input trace and the 27.5 mil 100 Ω load trace.
The laminate value matters as much as the formula. Rogers lists RO4350B at a design Dk of 3.66, not the 3.48 process value printed beside it, and the design figure is the one a quarter wave transformer calculator needs.
Foam coax velocity factors vary by brand. Times Microwave rates LMR-400 at 84%, so a generic 0.85 figure cuts the section 1.2% long, about 0.3 mm at 2.4 GHz and enough to shift the center frequency by the same 1.2%.
Connectors count as part of the line, so the cable itself must be cut shorter than the full quarter wave.
If two connectors on a 2.4 GHz PTFE coax section add 10 mm of length between them, the 21.70 mm quarter wave becomes an 11.70 mm cable cut, which is why CommScope says connector lengths belong in the calculation.
On HF, quarter wave transformer calculator lengths get long. A quarter wave of 75 Ω solid-PE coax at 14.2 MHz is 3.48 m (11.43 ft), and at 7.1 MHz a foam line with VF 0.85 needs 8.97 m, so coax transformers on the low bands are often coiled.
Bandwidth Shrinks as the Impedance Ratio Grows
A single 70.71 Ω section matching 50 Ω to 100 Ω holds VSWR under 1.5:1 across 78.4% of the center frequency, from 0.61 to 1.39 times f. Matching 50 Ω to 500 Ω with one section leaves only 18.3% at the same limit.
Delta f / f0 is the fractional bandwidth, Gammam is the largest reflection allowed, (VSWR - 1) / (VSWR + 1), and Z0 and ZL are the two impedances. The result holds for TEM lines such as coax and stripline.
| Load on 50 Ω | Section impedance | Bandwidth at VSWR 1.5 | Bandwidth at VSWR 2.0 | VSWR without a match |
|---|---|---|---|---|
| 100 Ω | 70.71 Ω | 78.4% | All frequencies | 2.00:1 |
| 150 Ω | 86.60 Ω | 46.0% | 83.9% | 3.00:1 |
| 200 Ω | 100.00 Ω | 35.1% | 62.5% | 4.00:1 |
| 300 Ω | 122.47 Ω | 25.6% | 45.0% | 6.00:1 |
| 500 Ω | 158.11 Ω | 18.3% | 32.0% | 10.00:1 |
The formula and a quarter wave transformer calculator sweep of the exact line equations agree to the first decimal in every row. A 100 Ω load never exceeds 2:1 at any frequency, because the unmatched VSWR is already exactly 2:1.
On a Smith chart the same match is easy to read, because the chart shows reflection and its phase in one picture.
The 100 Ω load sits at a reflection of 0.333 on the right of the real axis, the quarter-wave section rotates it to the center at the design frequency. From 0.5f to 1.5f the input traces an arc that crosses the 1.5:1 ring near 0.61f and 1.39f.
A 3λ/4 section gives the same impedance match at the center frequency but only about a third of the bandwidth.
For 50 Ω to 100 Ω at VSWR 1.5 it drops from 78.4% to 26.1%, so the longer cut only makes sense when a quarter wave is physically too short to reach.
The bandwidth row also tells you when a quarter wave transformer calculator design can stop at one section. If a single section already covers the band you need, more sections only add length.
Multi-Section Binomial and Chebyshev Designs
Splitting the impedance step into several sections widens the band in any quarter wave transformer calculator design. For 50 Ω to 200 Ω at VSWR 1.5, one section covers 35.1%, two binomial sections 69.9%, and three Chebyshev sections 119.5%.
This is the binomial rule, where N is the number of sections, n counts the steps from 0 to N, and the binomial coefficient spreads the total log step. It gives the flattest possible response near the center frequency.
| Sections, 50 to 200 Ω | Binomial impedances | Binomial bandwidth | Chebyshev impedances | Chebyshev bandwidth |
|---|---|---|---|---|
| 1 | 100.00 Ω | 35.1% | 100.00 Ω | 35.1% |
| 2 | 70.71 / 141.42 Ω | 69.9% | 77.41 / 129.18 Ω | 89.0% |
| 3 | 59.46 / 100.00 / 168.18 Ω | 89.4% | 70.15 / 100.00 / 142.54 Ω | 119.5% |
| 4 | 54.53 / 77.11 / 129.68 / 183.40 Ω | 102.3% | 66.91 / 86.63 / 115.43 / 149.45 Ω | 137.6% |
Chebyshev designs trade a small ripple inside the band for more width, so they beat binomial at every N here by 19 to 35 points. Binomial suits a link that needs the cleanest match right at one frequency, Chebyshev a wideband front end.
Both designs check against Pozar's textbook three-section examples for 50 Ω to 100 Ω. The binomial sections come out at 54.53, 70.71 and 91.70 Ω, and a Chebyshev design for a 0.05 maximum reflection at 57.38, 70.71 and 87.13 Ω.
The cost is length. A three-section FR-4 transformer at 2.4 GHz runs about three times the 17.53 mm of a single section, since each section is a quarter wave at the center frequency.
Each step differs slightly in length, because each trace width has its own effective permittivity and so its own guided wavelength.
Standard Coax as the Matching Section
A quarter wave of 75 Ω coax matches 50 Ω to 112.5 Ω exactly, and 93 Ω coax matches 50 Ω to 173 Ω. Two 75 Ω lines in parallel act as 37.5 Ω and match 50 Ω down to 28.1 Ω, handy for low-impedance antenna feeds.
Off-the-shelf coax rarely hits the ideal impedance, so a quarter wave transformer calculator check of the residual VSWR decides whether it is close enough.
Using 75 Ω coax instead of 70.71 Ω for a 50 Ω to 100 Ω match leaves a 1.13:1 VSWR at the center frequency, a 24.6 dB return loss.
The classic stacking harness relies on this. Two 50 Ω antennas each fed through a quarter wave of 75 Ω coax show 112.5 Ω at the junction, and the pair in parallel gives 56.25 Ω.
A 50 Ω feed line then sees 1.13:1, the same figure a VSWR to return loss calculator turns into 24.6 dB.
| Quarter-wave line | Matches 50 Ω to | Typical use |
|---|---|---|
| Two 50 Ω coax in parallel (25 Ω) | 12.5 Ω | Low-impedance beam feeds |
| Two 75 Ω coax in parallel (37.5 Ω) | 28.1 Ω | Yagi driven elements |
| 75 Ω coax | 112.5 Ω | Two-antenna stacking harness |
| 93 Ω coax | 173 Ω | High-impedance loads |
The same 70.71 Ω quarter-wave line also forms each arm of a two-way Wilkinson splitter on 50 Ω, which the N-way power divider calculator sizes for more outputs. Inside a quarter wave transformer calculator the arm is the same 50 Ω to 100 Ω match.
Reactive Loads and Transformer Basics
Two questions follow once the formula is clear: what the device actually is, and what happens when the load is not a pure resistance. Both answers use the same quarter wave transformer calculator math on 50 Ω systems at 2.4 GHz.
What is a quarter wave transformer?
A quarter wave transformer is a section of transmission line one quarter of a guided wavelength long, with a characteristic impedance between the source and the load.
It matches them at one design frequency with no lumped parts, as a trace on a board or a cut length of coax.
Its impedance is the geometric mean of the two sides, and its quarter wave transformer calculator length is a quarter wavelength in the line itself.
The 50 Ω to 100 Ω design needs a 70.71 Ω line, 17.53 mm on 62 mil FR-4 or 20.61 mm in solid PE coax at 2.4 GHz.
Do quarter wave transformers match complex impedances?
A quarter-wave section on its own matches only resistive loads. A complex load first needs a length of feed line to rotate it to a purely resistive point, at the nearest voltage maximum or minimum, where the transformer then goes.
For a 100 + j50 Ω load on 50 Ω, the reflection is 0.447 and the VSWR 2.62:1. The voltage maximum sits 13.28 electrical degrees from the load, about 2.53 mm of 50 Ω FR-4 line at 2.4 GHz, where the impedance is a real 130.9 Ω.
An 80.90 Ω quarter-wave section there completes the match, the same quarter wave transformer calculator step as for a resistive load.
The alternative is the voltage minimum 103.28 degrees out, a real 19.10 Ω that needs a 30.90 Ω section, which is a wide, awkward trace.
Reactance changes with frequency, so this match holds tightly only near the design point, so a real antenna load deserves a check with a VNA sweep.
An L-network from an RF impedance matching calculator is the shorter option when board space is tight, while the line approach suits higher power and needs no components.