Solar & Off-Grid Calculators
Solar & Off-Grid Calculators take a system from the daily load to the last cable. Count watt-hours, match panels to your peak sun hours, and size the battery bank. Then pick the charge controller, inverter, and PV wire.
How Solar & Off-Grid Calculators Fit Together
Every solar design runs in the same order. The load sets the energy, the sun sets the array, and the battery covers the hours with no sun. Solar & Off-Grid Calculators are grouped to follow that chain, so each result feeds the next tool.
Change one input early and everything after it moves. A bigger daily load needs more panels, more battery, a larger controller, and heavier wire.
| Step | Calculator | What it sizes |
|---|---|---|
| 1 | Off-Grid Load | Watt-hours per day and peak running watts |
| 2 | Peak Sun Hours | Daily sun energy at your location |
| 3 | Solar Panel Size | Array watts and panel count |
| 4 | Panel Tilt Angle | Year-round and seasonal tilt |
| 5 | Solar Battery Bank | Bank capacity in Ah and kWh |
| 6 | Charge Controller Size | Controller amps and PV input voltage |
| 7 | Solar Inverter Size | Continuous and surge watts |
| 8 | Solar Wire Size | PV and battery cable gauge |
| 9 | RV Solar | Panels and battery for a 12 V RV or van |
| 10 | Solar Payback | Years to recover a grid-tied system's cost |
Start With the Daily Off-Grid Load
The Off-Grid Load Calculator adds up what you run each day. Each item is its watts times its hours of use, and the total is your daily watt-hours.
Daily Wh = watts × hours per day, summed for every load
| Load | Watts | Hours | Wh per day |
|---|---|---|---|
| LED lights | 60 | 5 | 300 |
| Refrigerator (label: 1.2 kWh/day) | 150 running | Cycles | 1,200 |
| Laptop | 60 | 4 | 240 |
| Well pump | 1,000 | 1 | 1,000 |
| Total | 1,270 at once | - | 2,740 |
AC loads pass through the inverter, which loses some energy on the way. At 90% efficiency, that 2,740 Wh becomes about 3,040 Wh drawn from the battery. Use the larger number for every step that follows.
Read watts from the nameplate or a plug-in meter rather than guessing. A meter also catches standby draw, which runs all 24 hours and quietly adds to the total.
Peak Sun Hours and Solar Panel Size
A peak sun hour is one hour of sunlight at 1,000 W per square meter. Daily sun energy in kWh per square meter is the same number, so a site receiving 4.5 kWh/m² a day has 4.5 peak sun hours.
Two of the Solar & Off-Grid Calculators handle this step. The Peak Sun Hours Calculator gives the figure for your location. NREL's PVWatts draws on the same National Solar Radiation Database for its US estimates. Annual averages run above 6 in Arizona and under 4 in the Pacific Northwest.
The Solar Panel Size Calculator divides the daily load by sun hours and a derate. The derate covers heat, dust, wiring, and controller losses, and values of 0.75 to 0.85 are common.
Array watts = daily Wh ÷ (peak sun hours × derate)
For the 3,040 Wh load at 4 sun hours and a 0.80 derate, the array needs about 950 W. Three 400 W panels cover it with a little to spare.
Off-grid systems are sized for the worst month, not the yearly average. If December drops to 2.5 sun hours, the same load needs about 1,520 W, or four 400 W panels. Grid-tied systems can size to the annual average, because the grid fills the gap.
Solar Panel Tilt Angle
The Panel Tilt Angle Calculator sets how steeply the panels face the sky. A fixed tilt equal to your latitude gives good output across the whole year.
A steeper tilt favors winter, when the sun sits low. A common rule adds about 15° to latitude for winter and subtracts about 15° for summer. Off-grid arrays often lean toward the winter angle, since winter is the month they are sized for.
Denver sits near 40° north, so that means roughly 40° year-round or 55° for winter. In the US, panels face true south, which can differ from a compass reading by several degrees.
Solar Battery Bank Size
The Solar Battery Bank Calculator works out how much storage covers nights and cloudy spells. Days of autonomy is the number of days the bank must carry the load with no charging at all.
Battery Ah = daily Wh × days of autonomy ÷ depth of discharge ÷ system voltage
Depth of discharge depends on chemistry. Lead-acid banks last longest at about 50%, while LiFePO4 handles about 80% routinely.
| Chemistry | Usable depth of discharge | Bank for 3,040 Wh × 2 days at 24 V |
|---|---|---|
| Flooded lead-acid or AGM | 50% | 507 Ah |
| LiFePO4 | 80% | 317 Ah |
Cold cuts the usable capacity of lead-acid. LiFePO4 cells generally must not be charged below 32 °F (0 °C) unless the pack has a built-in heater, so a bank in an unheated shed needs a plan for winter.
For the runtime side of the same math, the Battery Life Calculator shows how long an existing pack lasts. The Battery Size Calculator covers general backup loads outside a solar system.
Charge Controller Size
The Charge Controller Size Calculator checks two limits, current and voltage, and both must pass. For current, divide array watts by battery voltage and add 25% margin.
Controller amps = array watts ÷ battery voltage × 1.25
A 1,600 W array on a 24 V bank gives 1,600 ÷ 24 × 1.25, or about 83 A. That rounds up to the next controller size, often 100 A, or two smaller controllers that split the array.
For voltage, the string's open-circuit voltage must stay below the controller's maximum input on the coldest morning. Panels make more voltage when cold, and NEC section 690.7 bases PV system voltage on the lowest expected ambient temperature.
Take three panels with a 37 V open-circuit voltage and a -0.28%/°C temperature coefficient. In series they read 111 V at 25 °C. At -20 °C the voltage rises 12.6%, to about 125 V, so a 100 V controller fails and a 150 V unit passes.
MPPT controllers turn extra panel voltage into charging current. PWM controllers do not, so they suit small systems where panel voltage closely matches the battery.
Solar Inverter Size
The Solar Inverter Size Calculator sets two ratings. Continuous watts must cover everything running at once, and surge watts must cover motor starts.
In the load example, the pump, refrigerator, lights, and laptop can all run together at about 1,270 W. With 25% headroom that is about 1,590 W, so a 2,000 W inverter fits. If the pump starts at three times its running watts, the inverter also needs a surge rating near 3,300 W.
Battery voltage matters here too. A 2,000 W inverter at 90% efficiency pulls about 185 A from a 12 V bank, 93 A from 24 V, and 46 A from 48 V. Lower current means thinner cable and smaller fuses, which is why larger systems move to 24 V or 48 V.
Solar Wire Size
The Solar Wire Size Calculator applies NEC 690.8, which sizes PV conductors at 156% of the module's short-circuit current. That is 125% for sunlight spikes above the rated level, times another 125% for continuous duty.
Minimum ampacity = Isc × 1.25 × 1.25
A string with a 13 A short-circuit current needs wire rated for at least 20.3 A before any temperature derating. Rooftop heat and conduit fill can push that higher, and the Wire Size Calculator works through the ampacity tables in full.
Wiring is the last step in the chain, and it is where Solar & Off-Grid Calculators most often catch a mistake. Low-voltage DC runs are usually limited by voltage drop rather than ampacity. Many designers aim for 2% to 3% on DC circuits, which takes heavy wire at 12 V.
| Copper wire | Drop at 12 V, 20 A, 25 ft one way |
|---|---|
| 10 AWG | 1.24 V (10.3%) |
| 6 AWG | 0.49 V (4.1%) |
| 4 AWG | 0.31 V (2.6%) |
Move the same 240 W to 24 V and 10 AWG carries only 10 A, so the drop falls to 0.62 V, or 2.6%. The Voltage Drop Calculator checks any run length, and the Voltage Rise Calculator covers inverter output feeding back toward the grid.
RV and Van Solar
The RV Solar Calculator runs the same chain as the other Solar & Off-Grid Calculators, inside tighter limits. Roof space caps the array, and most RVs and vans use a 12 V house bank.
Boondocking days take the place of autonomy days. Two dry-camping days on a 1,200 Wh daily load need about 3,000 Wh of LiFePO4, or roughly 250 Ah at 12 V.
Trees and a flat roof both cut output, since RV panels usually lie flat. That is why RV arrays are often sized larger than the daily load alone suggests.
Solar Payback for Grid-Tied Systems
The Solar Payback Calculator is the one tool among the Solar & Off-Grid Calculators built for grid-tied homes. It divides net system cost by yearly bill savings to give the years before the system pays for itself.
Payback years = net system cost ÷ yearly bill savings
A 6 kW system at 4.5 sun hours and a 0.80 derate makes about 7,880 kWh a year. At the EIA's April 2026 residential average of about 18.8 cents per kWh, that saves roughly $1,480 a year. If the system costs $18,000, payback lands near 12 years.
The federal 30% homeowner credit no longer shortens that figure. The Residential Clean Energy Credit under Section 25D ended for expenditures made after December 31, 2025. State rebates, utility incentives, and rising rates still count, so enter the ones that apply to you.
Net metering terms matter as much as price. If exported power earns less than the retail rate, every kWh sent back to the grid saves less. For a remote off-grid site, compare the system with the cost of bringing in a utility line instead.
Solar and Off-Grid FAQs
The worked numbers below use the same example system as the sections above, so each answer can be checked against the Solar & Off-Grid Calculators above.
How many solar panels do I need to run a house off-grid?
Divide daily watt-hours by peak sun hours and a 0.80 derate, then divide by panel wattage. A home using 10 kWh a day at 4 sun hours needs about 3,125 W, or eight 400 W panels. Size to your worst month, though. At 2.5 winter sun hours the same home needs about 5,000 W, or thirteen panels.
What size battery bank do I need for off-grid solar?
Multiply daily watt-hours by days of autonomy, divide by depth of discharge, then divide by system voltage. For 3,040 Wh a day, two days of autonomy, and LiFePO4 at 80% on 24 V, that is about 317 Ah. The same bank in lead-acid at 50% needs about 507 Ah. Two to three days of autonomy is a common starting point, with more in cloudy climates.
What size charge controller do I need for 400 watts of solar?
On a 12 V battery, 400 W ÷ 12 V × 1.25 is about 42 A. A 40 A controller sits right at that limit, so a 50 A unit leaves margin. On 24 V the same array needs about 21 A, which a 30 A controller covers. Check the string's cold-weather open-circuit voltage against the controller's maximum input voltage as well.
What size inverter do I need for an off-grid system?
Add the watts of everything that can run at the same time, then add about 25%. Check the surge rating against your largest motor start, such as a well pump, a refrigerator compressor, or a power tool. Motors can draw several times their running watts for a second or two. A pure sine wave inverter suits motors, chargers, and electronics alike.
How many peak sun hours do I get?
Annual averages in the continental US run from under 4 in the Pacific Northwest to above 6 in the desert Southwest. Winter values are much lower in northern states and can fall to half the yearly figure or less. Monthly values for your own address come from NREL's PVWatts or the Peak Sun Hours Calculator.
Is the 30% solar tax credit still available in 2026?
Not for homeowners. The Section 25D credit ended for expenditures made after December 31, 2025, so a system paid for and installed in 2026 gets no federal homeowner credit. Systems from 2025 or earlier can still carry unused credit forward. Leases and power purchase agreements fall under a separate business credit with its own deadlines.
Should I use 12 V, 24 V, or 48 V for an off-grid system?
Pick the voltage that keeps current manageable. A 2,000 W inverter pulls about 185 A at 12 V but only 46 A at 48 V. As a rough guide, 12 V suits RVs and small cabins, 24 V suits mid-size systems, and 48 V suits whole-home systems. Higher voltage also cuts voltage drop on long battery and array runs.