Water heater size calculator for the busiest hour of hot water use, giving tank size by first hour rating, tankless GPM and BTU, and the showers you get from a tank or wall geyser.
Enter your household and the busiest hour of hot water use.
Water and Uses
Flow and Winter
Shower and Heater
Tank Size by Household
| People | Busiest Hour | Electric Tank | Gas Tank |
|---|---|---|---|
| 1 | 30.7 gal | 30 Gallon | 40 Gallon |
| 2 | 46.4 gal | 30 Gallon | 40 Gallon |
| 3 | 62.1 gal | 55 Gallon | 40 Gallon |
| 4 | 77.9 gal | 80 Gallon | 75 Gallon |
| 5 | 93.6 gal | 2 × 80 Gallon | 100 Gallon |
| 6 | 109.3 gal | 2 × 80 Gallon | 100 Gallon |
Step-by-Step Math
- Hot share = (105°F - 50°F) ÷ (120°F - 50°F) = 78.6%
- Hot water per shower = 10.0 min × 2 GPM × 0.786 = 15.714 gal
- Kitchen, laundry and shaving = 1 × 7 + 2 × 3 + 0 × 25 + 1 × 2 = 15 gal
- First hour rating needed = 3 × 15.714 gal + 15 gal = 62.143 gal
- Recovery = 4,500 W × 3.412 = 15,355 BTU/h × 0.98 ÷ (8.34 × 70.0°F) = 25.78 gal/h
- Est. FHR = (0.7 × 55 gal + 25.775 gal) = 64.3 gal, at least the 62.1 gal needed
- Recommended size = 55 Gallon electric tank
Busiest-Hour Gallons in a Water Heater Size Calculator
A four-person home with three 10-minute showers in its busiest hour needs a first hour rating of at least 62.1 gallons (235 L). That busiest hour, not the head count, sets the answer in any water heater size calculator for home use.
The U.S. Department of Energy sizing guide sizes storage heaters this way. You add up the hot water used in your heaviest 60 minutes and match it to the first hour rating (FHR) on the label.
Here D is peak-hour demand in gallons, ns is showers in that hour, t is shower length in minutes, q is showerhead flow in GPM and h is the hot share of the mix. The other terms count dishwasher loads, sink uses, top-load washer loads and shaves.
The DOE worksheet figures behind a water heater size calculator in gallons are 7 gal per dishwasher load, 3 gal per hand-wash or food-prep use, 25 gal per top-loader load, 15 gal per front-loader load and 2 gal per shave.
For the default home, one dishwasher load, two sink uses and one shave add 15 gal. Three showers at 15.71 gal of hot water each add 47.1 gal, so the hour totals 62.1 gal.
Shower Mix Math That Shrinks DOE's 20 Gallons
A 10-minute shower at 2 GPM uses 20 gallons in total, but only 15.7 of them come from the heater. The rest is cold water blended in at the valve to bring 120°F tank water down to a 105°F shower.
With 50°F incoming water, a 120°F tank and a 105°F shower, h = 55 / 70 = 0.786. In metric that is 10°C in, 48.9°C in the tank and 40.6°C at the head, with the same 78.6% hot share.
The DOE worksheet counts 20 gal of hot water per shower. The same default home then adds up to 75 gal instead of 62.1 gal. Sizing on that shortcut moves a water heater size calculator result from a 55-gallon electric tank to an 80-gallon one.
Turning the tank up to 130°F drops the hot share to 68.8%, or 13.75 gal per shower. Peak demand falls to 56.3 gal, and a 50-gallon electric tank covers it, but only with a mixing valve at the heater.
The DOE guide warns that 140°F water raises the scald risk, and 120°F suits most uses. Storing hotter to shrink the tank is a fair trade only when a thermostatic mixing valve caps the water at the taps.
Tank Size by Showers in the Busiest Hour
Each extra 10-minute, 2 GPM shower in the busiest hour adds 15.7 gal (59.5 L) to the first hour rating you need. The table keeps 15 gal of kitchen use and one shave in every row, with 50°F water heated to 120°F.
| Showers in Busiest Hour | Peak Demand | Minimum FHR | Electric Tank, 4,500 W | Gas Tank With Listed FHR |
|---|---|---|---|---|
| 1 | 30.7 gal (116 L) | 31 gal | 30 gal | 40 gal, FHR 75 |
| 2 | 46.4 gal (176 L) | 47 gal | 30 gal | 40 gal, FHR 75 |
| 3 | 62.1 gal (235 L) | 63 gal | 55 gal | 40 gal, FHR 75 |
| 4 | 77.9 gal (295 L) | 78 gal | 80 gal | 50 gal, FHR 90 |
| 5 | 93.6 gal (354 L) | 94 gal | 2 × 80 gal | 65 gal, FHR 116 |
| 6 | 109.3 gal (414 L) | 110 gal | 2 × 80 gal | 65 gal, FHR 116 |
The electric column follows the usual electric water heater size calculator estimate of 70% of the tank plus one hour of 4,500 W heating. The gas column lists real A.O. Smith models whose published first hour rating clears the demand.
A 30-gallon electric tank clears two showers by only 0.4 gal, so treat that row as the edge of any water heater size calculator range. Long showers, a 2.5 GPM head or a top-load wash in the same hour push it past.
Five or more showers in one hour exceed any single standard electric tank in a water heater size calculator estimate. That is where a gas tank with a 65,000 BTU/h burner, or two heaters, starts to make sense on cost and space.
Count the people showering in the busiest hour, not everyone in the house, before trusting a water heater size calculator result.
Four people who split showers between morning and night only load the busiest hour with two, which makes a 46.4-gal hour instead of 77.9.
First Hour Rating Beats Tank Size
Two 50-gallon gas tanks can deliver 90 or 93 gallons in the first hour, and a 65-gallon tank delivers 116. The burner size, not the gallons stamped on the shell, makes most of that gap.
| Model | Tank | Input | Recovery at 90°F Rise | Listed FHR | 0.7 × Tank + Recovery |
|---|---|---|---|---|---|
| GCVT-40 | 40 gal | 50,000 BTU/h | 51 gal/h | 75 gal | 78.6 gal |
| GCVT-50 | 50 gal | 50,000 BTU/h | 51 gal/h | 90 gal | 85.6 gal |
| GCVX-50 | 50 gal | 65,000 BTU/h | 67 gal/h | 93 gal | 100.8 gal |
| GCV-65 | 65 gal | 65,000 BTU/h | 67 gal/h | 116 gal | 111.3 gal |
Ratings come from the A.O. Smith residential gas water heater data sheet. The last column uses recovery at a 90°F rise, and it lands within 9% of every listed rating.
V is the tank volume in gallons and R is recovery in gallons per hour. About 70% of a full tank leaves hot before cold inflow cools the outlet, which is why the 0.7 factor sits on V.
Swapping a 40-gallon tank for a 50-gallon one on the same burner adds about 7 gal of first-hour water. That is under half of one 15.7-gal shower, so a bigger burner often beats a bigger shell in a water heater size calculator comparison.
A gas water heater size calculator estimate is a shortlist tool. The EnergyGuide label prints the real number as "Capacity (first hour rating)", and the model you buy should meet or beat your peak demand on that line.
Gas vs Electric Recovery and Reheat Time
A 40,000 BTU/h gas burner reheats about 52 gal per hour at a 70°F rise, while a 4,500 W electric element reheats about 26 gal. Gas recovers twice as fast, so it can sit in a smaller tank in a gas water heater size calculator estimate.
P is the input in BTU/h (watts × 3.412 for electric), η is recovery efficiency and ΔT is the rise in °F. The 8.34 is the weight of one gallon of water in pounds, and one BTU raises one pound by 1°F.
The 76% gas efficiency checks out against published figures. State Water Heaters lists 41 gal/h at a 90°F rise for a 40,000 BTU/h heater, and the formula gives 40.5. Electric elements sit in the water, so 98% applies there.
| Temperature Rise | Gas, 40,000 BTU/h | Electric, 4,500 W | 50 gal Reheat After Use, Gas | 50 gal Reheat After Use, Electric |
|---|---|---|---|---|
| 50°F (28°C) | 72.9 gal/h | 36.1 gal/h | 29 min | 58 min |
| 70°F (39°C) | 52.1 gal/h | 25.8 gal/h | 40 min | 1 h 21 min |
| 90°F (50°C) | 40.5 gal/h | 20.0 gal/h | 52 min | 1 h 45 min |
Reheat after use counts the 35 gal (70%) that leaves hot from a full 50-gallon tank, which is the share the heater must refill between busy hours.
A new 50-gallon electric tank filled with 50°F water needs close to 2 hours to reach 120°F. An 80-gallon electric tank needs about 3 hours 6 minutes, so a slow first heat-up is normal and not a fault.
Homes that heat water from a boiler through an indirect tank size both together. The Boiler Size Calculator covers the space-heating load that the boiler has to carry alongside the tank.
An electric water heater size calculator result runs larger than a gas one for this reason. The default home needs 55 gal electric, while the same hour fits a 40-gallon gas tank with a listed FHR of 75.
Tankless Water Heater Size Calculator Numbers in GPM and BTU
A tankless heater for one 2.5 GPM shower plus a 0.75 GPM faucet needs 3.25 GPM at a 70°F rise. That is the DOE's own example, and it takes 113,841 BTU/h of heat into the water.
H is heat into the water in BTU/h, Q is flow in GPM and ΔT is the rise in °F. The 500.4 is 8.34 lb per gallon times 60 minutes per hour, the same 8.34 used in tank recovery.
| Fixtures at Once | Flow | Gas Input at 90% | Electric | Amps at 240 V |
|---|---|---|---|---|
| 1 shower | 2.50 GPM (9.5 L/min) | 97,300 BTU/h | 25.7 kW | 106.9 A |
| 1 shower + faucet | 3.25 GPM (12.3 L/min) | 126,490 BTU/h | 33.4 kW | 139.0 A |
| 2 showers | 5.00 GPM (18.9 L/min) | 194,600 BTU/h | 51.3 kW | 213.9 A |
| 2 showers + faucet | 5.75 GPM (21.8 L/min) | 223,790 BTU/h | 59.0 kW | 245.9 A |
| 3 showers | 7.50 GPM (28.4 L/min) | 291,900 BTU/h | 77.0 kW | 320.8 A |
All rows use a 70°F rise and a 90% efficient gas unit. With a different rise in a water heater size calculator for GPM, the gas and electric columns scale in direct proportion.
Gas handles whole-house flow far better than electric. DOE notes that a gas unit typically gives about 5 GPM at a 70°F rise, while an electric one gives about 2 GPM.
Two showers on an electric tankless need about 214 A, which is more than a whole 200 A home service. That one number rules electric out for most two-bathroom houses before price even comes up.
A tankless water heater size calculator answer has to be read against the unit's rating chart. Look for the flow it delivers at your rise, not the headline maximum GPM printed on the box.
Winter Inlet Water and Lost Tankless Flow
A tankless unit sized for 3.25 GPM with 50°F water drops to 2.84 GPM when the inlet falls to 40°F. That 12% loss is why hot water seems to run out faster or run cooler in winter.
| Incoming Water | Rise to 120°F | 3.25 GPM Unit Gives | Flow Change | 5 GPM Unit Gives |
|---|---|---|---|---|
| 60°F (15.6°C) | 60°F | 3.79 GPM | +17% | 5.83 GPM |
| 50°F (10°C) | 70°F | 3.25 GPM | Design point | 5.00 GPM |
| 40°F (4.4°C) | 80°F | 2.84 GPM | -12% | 4.38 GPM |
| 32°F (0°C) | 88°F | 2.59 GPM | -20% | 3.98 GPM |
A 5 GPM unit fed 32°F water can no longer run two 2.5 GPM showers at full heat. Use a winter inlet in any water heater size calculator, since a summer inlet leaves a household short exactly when showers run longest.
Tanks lose ground the same way. A 4,500 W element drops from 25.8 to 20.0 gal/h when the rise grows from 70°F to 90°F, so winter recovery is about 22% slower.
DOE suggests 50°F (10°C) as the water heater size calculator inlet unless you know better. To find your groundwater temperature, run a cold tap for a few minutes and hold a kitchen thermometer in the stream, ideally in midwinter.
Cold basements and crawl spaces also pull heat from hot pipes between draws. The Insulation Surface Temperature Calculator helps choose a wrap thickness for runs from the heater.
Geyser Litres for Showers and Bucket Baths
A 25-litre geyser holds enough hot water for about one bucket bath, not one shower. A 10-minute shower at 7.57 L/min needs 59.6 L of hot water, more than twice what most wall geysers store.
Haier's sizing guide puts a family of four at 15 to 25 L for standard showers. In water heater size calculator math, a 25 L tank runs a 2 GPM shower for only 3.3 minutes before it cools.
A 20-litre bucket mixed to 40.6°C takes 15.7 L from a 48.9°C geyser fed 10°C water. With a 2 kW element, each extra bucket needs about 22 minutes of reheating, which sets the wait between family members.
| Geyser | Usable Hot Water | Buckets From Full | Buckets in First Hour | Reheat After Use |
|---|---|---|---|---|
| 5 L, 2 kW | 3.5 L | 0.2 | 2.9 | 5 min |
| 10 L, 2 kW | 7.0 L | 0.4 | 3.2 | 10 min |
| 15 L, 2 kW | 10.5 L | 0.6 | 3.4 | 15 min |
| 25 L, 2 kW | 17.5 L | 1.1 | 3.8 | 24 min |
| 50 L, 2 kW | 35.0 L | 2.2 | 4.9 | 48 min |
The first-hour count assumes baths spread across the hour so the element keeps heating between them. Back to back, only the "from full" column is hot right away.
Showers need a real tank. A 200-litre tank gives 2.8 full 10-minute showers back to back with a 3 kW element, or 3.2 with 4.5 kW, counting the heating that runs during each shower.
| Tank | Element | Showers Back to Back | Nonstop Shower | Hot in First Hour |
|---|---|---|---|---|
| 50 L | 2 kW | 0.6 | 6.7 min | 78.4 L |
| 100 L | 3 kW | 1.4 | 14.4 min | 135.0 L |
| 150 L | 3 kW | 2.1 | 21.6 min | 170.0 L |
| 200 L | 3 kW | 2.8 | 28.8 min | 205.0 L |
| 200 L | 4.5 kW | 3.2 | 32.4 min | 237.5 L |
N is showers back to back, V is tank litres, q is flow in L/min, h is the hot share, R is recovery in L/h and t is shower length. Subtracting R/60 credits the element for heating while the shower runs.
A hot water heater size calculator in litres works the same as one in gallons. Only the tank list changes, from 30 to 80 gal tanks to the 5 to 200 L sizes sold in India, the UK and Australia.
Household Hot Water Answers by Family Size
These answers use the same 120°F (48.9°C) storage, 105°F (40.6°C) shower and 50°F (10°C) inlet as the tables above, so each water heater size calculator figure can be compared directly.
What size water heater for 2 people?
Two people who shower in the same hour need about 46.4 gal (176 L) of first-hour delivery with kitchen use, which a 40-gallon tank covers. A 30-gallon electric tank works only when the showers are short.
A 50 L water heater is not enough for two showers. It gives 0.6 of a 10-minute shower before cooling, or about 6.7 minutes. It suits two people only for bucket baths, with 2.2 buckets ready from a full tank.
Is a 5L geyser enough for 2 people?
A 5 L geyser stores only 3.5 L of usable hot water, a fifth of one 15.7 L bucket. It reheats in about 5 minutes after use, so it suits a kitchen sink or wash basin, not bathing for two people.
Which is better, a 3L or 5L geyser?
For a kitchen or wash basin, a 3 L instant geyser at 3 kW is the better choice, since it heats on flow. It gives 1.44 L/min with a 30°C rise and 2.15 L/min with a 20°C rise, enough for a tap but not a shower.
A 5 L storage geyser at 2 kW holds 3.5 L hot and refills in about 5 minutes. It wins where the water is very cold, because a short draw comes out at full heat instead of running lukewarm.
What size geyser is ideal for a family of 3?
In water heater size calculator terms, a 25 L geyser at 2 kW suits three people taking bucket baths. It gives one bucket right away and about 3.8 in the first hour if baths are spaced 22 minutes apart.
Three people who take 10-minute showers back to back need more than a geyser. A 200 L tank with a 4.5 kW element gives 3.2 such showers before the water cools.
What size water tank for a family of four?
For a family of four, the water heater size calculator math with three 10-minute showers in the busiest hour gives a 62.1 gal first-hour need. That is a 55-gallon electric tank.
On gas, a 40-gallon tank with a listed FHR of 75 covers the same hour. Four showers in one hour raise the need to 77.9 gal, which takes an 80-gallon electric or a 50-gallon gas tank rated at 90.
What size water tank for a 3 bedroom house?
Size a 3 bedroom house by bathrooms and morning showers, since bedrooms play no part in water heater size calculator math.
Two bathrooms running at once need 5 GPM tankless at a 70°F rise, or about 78 gal of first-hour delivery if four people shower in one hour.
How many litres is a 7 minute shower?
A 7-minute shower at 2 GPM (7.57 L/min) uses 53 L of water, and the 41.6 L of hot water is what counts in water heater size calculator math. A 2.5 GPM (9.46 L/min) head uses 66.2 L, while a 1.5 GPM low-flow head uses 39.7 L.
What size tankless water heater do I need to replace a 100 gallon tank water heater?
A home that needed a 100-gallon tank usually runs three showers at once, which is 7.5 GPM at a 70°F rise. That takes 262,710 BTU/h of heat, or 291,900 BTU/h of gas input at 90% efficiency.
How many tankless hot water heaters do I need?
Divide the gas input from a tankless water heater size calculator by the input of one unit. At 199,000 BTU/h per unit, two showers plus a faucet (223,790 BTU/h) need two units, while one shower plus a faucet (126,490 BTU/h) needs one.
Tankless is not always better for large families. Three electric showers at once need 321 A at 240 V, so large households either go gas tankless with two units or keep a high-FHR gas tank.