Differential pair impedance calculator for edge-coupled microstrip and stripline: get Zdiff from width, gap and stackup, or solve the width or gap that hits a 90 or 100 ohm target.
Enter the pair geometry and stackup to get the differential impedance (Zdiff).
Pair Length & Length Mismatch
Pair Cross-Section Diagram
Zdiff vs Spacing Chart
Spacing and Width Table
| Spacing S | S ÷ H | Zdiff at W 5.00 mil | Width for 100 Ω |
|---|---|---|---|
| 3.00 mil (76.2 µm) | 0.750 | 84.0 Ω | 3.34 mil (84.8 µm) |
| 4.00 mil (0.102 mm) | 1.00 | 89.5 Ω | 3.92 mil (99.5 µm) |
| 5.00 mil (0.127 mm) | 1.25 | 93.8 Ω | 4.37 mil (0.111 mm) |
| 6.00 mil (0.152 mm) | 1.50 | 97.2 Ω | 4.71 mil (0.120 mm) |
| 7.00 mil (0.178 mm) | 1.75 | 99.8 Ω | 4.98 mil (0.127 mm) |
| 8.00 mil (0.203 mm) | 2.00 | 101.9 Ω | 5.19 mil (0.132 mm) |
| 10.0 mil (0.254 mm) | 2.50 | 104.9 Ω | 5.48 mil (0.139 mm) |
| 12.0 mil (0.305 mm) | 3.00 | 106.7 Ω | 5.66 mil (0.144 mm) |
| 16.0 mil (0.406 mm) | 4.00 | 108.5 Ω | 5.83 mil (0.148 mm) |
| 20.0 mil (0.508 mm) | 5.00 | 109.2 Ω | 5.90 mil (0.150 mm) |
Step-by-Step Math
Zdiff Equations Behind Every Differential Pair Impedance Calculator
A pair of 5 mil traces 7 mil apart, 4 mil above the plane on εr 4.2 laminate with 1 oz copper, measures 99.8 Ω differential. Two closed-form steps get there: one trace's impedance, then a cut for coupling.
Z0 is a single trace's impedance in ohms, εr the laminate's dielectric constant, H the height to the plane, W the trace width and T the copper thickness, all in one length unit. It is the IPC-2141 surface microstrip equation.
S is the edge-to-edge gap between the traces. The coupling term comes from the National Semiconductor LVDS Owner's Manual, and each line's odd-mode impedance is exactly half of Zdiff.
Worked through, 87 ÷ √5.61 is 36.73, and 5.98 × 4 ÷ (0.8 × 5 + 1.378) is 4.448, whose natural log is 1.492. That makes Z0 54.8 Ω before the second trace is added.
The coupling term is 0.48 × e-1.68, or 0.0895. Then 2 × 54.8 × (1 - 0.0895) gives 99.8 Ω, the same value as any differential pair impedance calculator formula built on these equations, to the decimal.
For a differential pair impedance calculator in Excel, put W, S, H and T in mils in B1 to B4 and εr in B5. Then type =2*87/SQRT(B5+1.41)*LN(5.98*B3/(0.8*B1+B4))*(1-0.48*EXP(-0.96*B2/B3)).
100 Ω Pair Geometry on Common Stackups
In differential pair impedance calculator terms, a 100 Ω surface pair over 4 mil of εr 4.2 laminate with 1 oz copper needs 4.37 mil traces at a 5 mil gap, or 5.19 mil traces at an 8 mil gap.
| Dielectric Height H | Width at 5 mil Gap | Width at 8 mil Gap | Width = Gap (1:1) | Each Trace Z0 at 1:1 |
|---|---|---|---|---|
| 3 mil (0.076 mm) | 3.24 mil | 3.73 mil | 1.57 mil | 70.4 Ω |
| 4 mil (0.102 mm) | 4.37 mil | 5.19 mil | 3.83 mil | 61.8 Ω |
| 5 mil (0.127 mm) | 5.33 mil | 6.47 mil | 5.63 mil | 59.7 Ω |
| 6 mil (0.152 mm) | 6.18 mil | 7.60 mil | 7.35 mil | 58.7 Ω |
| 8 mil (0.203 mm) | 7.70 mil | 9.56 mil | 10.7 mil | 57.6 Ω |
The 1:1 width-to-gap habit only suits thicker dielectrics. Over 3 mil, a 1:1 pair at 100 Ω needs 1.57 mil (40 µm) lines and gaps, so thin stackups take a gap wider than the trace instead.
A 100 Ω pair is not two 50 Ω traces. In the 1:1 pair over 4 mil, each line alone measures 61.8 Ω, and coupling between them pulls the pair down to 100 Ω.
Lower targets widen the same 1:1 pair. Over 4 mil, a 100 ohm differential pair calculator result of 3.83 mil grows to 5.67 mil (0.144 mm) for 90 Ω and to 6.55 mil (0.166 mm) for 85 Ω.
Targets for USB, HDMI, PCIe and Ethernet
Every differential pair impedance calculator result needs a target from the interface spec. TI's processor board design guide sets USB at 90 Ω and PCIe, SATA and HDMI TMDS pairs at 100 Ω, each with its own tolerance window.
| Interface Pair | Target Zdiff | Allowed Range | Skew Within Pair |
|---|---|---|---|
| USB 2.0 DP/DM | 90 Ω | 81 to 99 Ω (±10%) | 50 mil |
| USB SuperSpeed TX/RX | 90 Ω | 83.7 to 96.3 Ω (±7%) | 5 mil |
| PCIe TX/RX | 100 Ω | 90 to 110 Ω (±10%) | 5 mil |
| SATA TX/RX | 100 Ω | 85 to 115 Ω (±15%) | 5 mil |
| HDMI TMDS | 100 Ω | 90 to 110 Ω (±10%) | 5 mil |
Many PCIe references quote 85 Ω instead of 100 Ω. The chip vendor's layout guide is the one that counts before any differential pair impedance calculator run, since TI's own table holds PCIe at 100 Ω while other platforms specify 85 Ω.
The 100 Ω habit traces back to LVDS. National's LVDS Owner's Manual asks for closely coupled traces designed for 100 Ω differential impedance to match the 100 Ω receiver termination, and Ethernet pairs use 100 Ω too.
USB sits at 90 Ω because the board pair matches the cable's 90 Ω differential pair, while HDMI matches a 100 Ω cable. Any mismatch between board and cable shows up as a reflection at the connector.
Tighter Gaps Lower Zdiff, Within Limits
Closing the gap lowers Zdiff in differential pair impedance calculator math, and opening it raises Zdiff toward twice Z0. With 5 mil traces over 4 mil, Zdiff climbs from 84.0 Ω at a 3 mil gap to 109.2 Ω at 20 mil, against a 109.6 Ω ceiling.
| Gap S | S ÷ H | Zdiff | Coupling Cut |
|---|---|---|---|
| 3 mil (0.076 mm) | 0.75 | 84.0 Ω | 23.4% |
| 4 mil (0.102 mm) | 1.00 | 89.5 Ω | 18.4% |
| 5 mil (0.127 mm) | 1.25 | 93.8 Ω | 14.5% |
| 7 mil (0.178 mm) | 1.75 | 99.8 Ω | 8.95% |
| 10 mil (0.254 mm) | 2.50 | 104.9 Ω | 4.35% |
| 15 mil (0.381 mm) | 3.75 | 108.2 Ω | 1.31% |
| 20 mil (0.508 mm) | 5.00 | 109.2 Ω | 0.40% |
Two 50 Ω traces stop being a 100 Ω pair once they couple. At 5.94 mil wide over 4 mil each line is 50 Ω, yet at a 1:1 gap the pair measures only 88.5 Ω, and a gap three times the width is needed to reach 99.3 Ω.
Past a gap of about four times H, the coupling cut falls under 2% and the pair behaves like two separate lines in any differential pair impedance calculator.
A loosely coupled 100 Ω pair then needs each trace close to 51 Ω on its own, which the Microstrip Impedance Calculator sizes directly.
Edge-Coupled Stripline and Its Coupling Constant
An inner 100 Ω pair centered between planes 16 mil apart, on εr 4.2 with 1 oz copper, needs 3.36 mil traces at a 5 mil gap or 4.12 mil traces at an 8 mil gap.
B is the plane-to-plane spacing with the pair centered between the planes, and W, T and εr mean the same as on the surface. The constant 1.9 is the IPC-2141 stripline term 4 ÷ (0.67π).
National's manual gives 0.374 for the coupling constant. A 0.347 version printed in Doug Brooks's 1998 Printed Circuit Design article reads up to 4% high on tightly coupled pairs.
Check which constant a stripline differential pair impedance calculator result carries before trusting a tight inner pair, since the gap between them grows as S shrinks.
| Plane Spacing B | Width at 5 mil Gap | Each Trace Z0 | Width at 8 mil Gap | Each Trace Z0 | 5 mil Gap Pair With 0.347 |
|---|---|---|---|---|---|
| 12 mil (0.305 mm) | 2.44 mil | 56.3 Ω | 2.96 mil | 52.9 Ω | 100.9 Ω |
| 16 mil (0.406 mm) | 3.36 mil | 58.9 Ω | 4.12 mil | 54.8 Ω | 101.3 Ω |
| 20 mil (0.508 mm) | 4.18 mil | 61.1 Ω | 5.14 mil | 56.6 Ω | 101.6 Ω |
| 24 mil (0.610 mm) | 4.94 mil | 62.8 Ω | 6.06 mil | 58.3 Ω | 101.9 Ω |
The same manual notes the constant may double to 0.748 for stripline pairs closer than 12 mil, a sign of how rough the closed form gets on tight inner pairs. Send those to the fab's field solver before release.
Fabrication Drift: Width, Copper and Dk
Trace width moves a differential pair impedance calculator result the most. On the 99.8 Ω surface pair, traces 10% wider drop it 4.80 Ω, a 10% wider gap adds 1.52 Ω, and a 10% thicker dielectric adds 4.65 Ω.
| Change From Drawn | Zdiff Shift | New Zdiff |
|---|---|---|
| Width +10% (5.5 mil) | -4.80 Ω | 95.0 Ω |
| Width -10% (4.5 mil) | +5.17 Ω | 105.0 Ω |
| Gap +10% (7.7 mil) | +1.52 Ω | 101.3 Ω |
| Height +10% (4.4 mil) | +4.65 Ω | 104.5 Ω |
| Dk 4.2 to 4.5 | -2.57 Ω | 97.3 Ω |
| Dk 4.2 to 3.8 | +3.76 Ω | 103.6 Ω |
| Copper 35 to 55 µm | -9.14 Ω | 90.7 Ω |
Outer layers rarely finish at bare 1 oz foil. IPC-6012 adds an average of 20 µm of surface plating on Class 2 boards, per this IPC-6012 summary, and 55 µm of copper drops the pair 9.14 Ω, most of a ±10% budget.
Ask the fab for finished copper and pressed dielectric height before any differential pair impedance calculator run. A width solved on nominal 1 oz and 4 mil can miss by 5 to 10 Ω, and one mil less width adds 10.8 Ω on this pair.
Skew and Delay From Length Mismatch
A surface pair on εr 4.2 carries signals at 138.8 ps per inch, so every 10 mil of P/N mismatch adds 1.39 ps of skew. Inside the board the same laminate is slower, at 174.2 ps per inch or 1.74 ps per 10 mil.
tpd is the surface microstrip delay in ps per inch. The 0.475 and 0.67 terms blend the laminate below the trace with the air above it, which is why a surface pair runs faster than a buried one.
This stripline form applies when laminate surrounds the trace on both sides, so the full εr sets the speed. On εr 4.2 the stripline delay is 25% longer than the surface figure.
TI's 5 mil intra-pair limit for USB SuperSpeed, PCIe, SATA and HDMI equals 0.69 ps on a surface pair, while USB 2.0's 50 mil allowance is 6.9 ps. Its 550 mil total skew limit between PCIe lanes is 76 ps.
A 6 in surface pair takes 833 ps end to end. Matching lanes by delay rather than raw length matters when one lane runs on the surface and another inside the board.
Solder Mask, Coplanar Ground and Field Solvers
Closed-form differential pair impedance calculator equations ignore solder mask, etch taper, copper roughness and frequency-dependent Dk. Altium's guide to analytical calculators lists all four as gaps that a field solver closes.
Mask over a surface pair always pulls Zdiff below the bare-copper result, so a pair solved at exactly 100 Ω bare finishes low. The Embedded Microstrip Impedance Calculator estimates a trace under a dielectric layer.
Copper pour beside a pair turns it into a coplanar structure, which no edge-coupled differential pair impedance calculator models. Keeping pour at least three trace widths away, 15 mil for 5 mil traces, keeps it close to the edge-coupled figure.
Broadside-coupled pairs, stacked one above the other, have no closed-form equation at all; National's manual sends them straight to a field solver.
For pairs beyond any closed-form differential pair impedance calculator, Altium's Layer Stack Manager has a field solver built in, and fabs such as JLCPCB publish calculators tied to their own stackups.
Differential Impedance in Plain Terms
Differential impedance is what a signal driven between the two traces sees, so every differential pair impedance calculator target matches the termination across the receiver. Common interfaces put that resistor at 90 or 100 Ω.
What is differential pair impedance (zDiff)?
Zdiff is the impedance between the two lines of a pair when they carry equal and opposite signals, and it equals twice the odd-mode impedance of either line. A 99.8 Ω pair has 49.9 Ω odd-mode impedance, though each trace alone measures 54.8 Ω.
The step from 54.8 Ω to 49.9 Ω is the coupling. Each trace's field partly cancels its partner's, which lowers each line's impedance by 8.95% in this pair and by more as the gap shrinks.
How do I use the differential pair impedance calculator?
Begin with three numbers from the fabricator: finished copper thickness, pressed dielectric height and laminate Dk. Then fix whichever of width or gap the routing allows and solve the other for the interface target.
Check drift before release. On the example pair a 1 mil narrower trace adds 10.8 Ω, so treat the differential pair impedance calculator answer as the starting geometry and confirm it with the fab's field solver.