Inductive Reactance Calculator

Updated

Inductive reactance calculator for XL = 2πfL from pH to H and Hz to GHz, with coil impedance, phase, current, L or f from XL, inductance from V and I, and series or parallel coils.

Inductive Reactance

Enter the inductance and the AC frequency. XL = 2πfL, so reactance rises in step with both.

Coil Resistance & AC Voltage--
188.5 Ω Inductive Reactance
XL = 2π × 60 Hz × 500 mH
188.8 Ω Coil Impedance
Phase Angle (θ)86.96°
Q from DCR (Upper Limit)18.85
R and XL add at right angles: Z = √(R² + XL²), and θ = atan(XL ÷ R).
635.7 mA Current at 120 V
Reactive Power76.18 VAR
Voltage Across XL119.8 V
RMS current I = V ÷ Z, and the reactive power the coil trades back and forth each cycle.
14.07 µF Cap Gives XC = XL
Susceptance (BL)5.305 mS
Angular Frequency (ω)377 rad/s
A capacitor this size has the same reactance at this frequency, so the pair resonates.
157.1 Ω XL at 50 Hz
At 400 Hz1.257 kΩ
At 1 kHz3.142 kΩ
Reactance rises in direct proportion to frequency, so twice the frequency gives twice the XL.
Impedance Triangle and WaveformZ 188.8 Ω at 86.96°
XL 188.5 ΩR 10 ΩZ 188.8 Ω at 86.96°VoltageCurrent, lags 86.96°
Reactance Across Frequencies500 mH from 50 Hz to 10 MHz
FrequencyReactance (XL)Impedance (Z)PhaseCurrent
50 Hz157.1 Ω157.4 Ω86.36°762.4 mA
60 Hz188.5 Ω188.8 Ω86.96°635.7 mA
120 Hz377 Ω377.1 Ω88.48°318.2 mA
400 Hz1.257 kΩ1.257 kΩ89.54°95.49 mA
1 kHz3.142 kΩ3.142 kΩ89.82°38.2 mA
10 kHz31.42 kΩ31.42 kΩ89.98°3.82 mA
100 kHz314.2 kΩ314.2 kΩ90°382 µA
1 MHz3.142 MΩ3.142 MΩ90°38.2 µA
10 MHz31.42 MΩ31.42 MΩ90°3.82 µA
Step-by-Step Math6 steps
1. Convert to SIL = 0.5 H, f = 60 Hz
2. Angular Frequencyω = 2π × 60 Hz = 377 rad/s
3. Inductive ReactanceXL = 2π × 60 Hz × 0.5 H = 188.5 Ω
4. ImpedanceZ = √(10² + 188.496²) = 188.8 Ω, θ = 86.96°
5. CurrentI = 120 V ÷ 188.8 Ω = 635.7 mA
6. Result188.5 Ω Inductive Reactance
Voltage Leads Current by 86.96°
XL rises in step with frequency: at 120 Hz this 500 mH coil would show 377 Ω.

Inductive Reactance Calculator Values From 50 Hz to 10 MHz

A 0.5 H inductor at 60 Hz has 188.5 Ω of inductive reactance, and the same coil on 50 Hz mains has 157.1 Ω. Reactance rises in a straight line with both frequency and inductance, so doubling either one doubles XL.

XL is the inductive reactance in ohms, f is the frequency in hertz and L is the inductance in henries. A 10 mH coil enters as 0.01 H and 100 kHz as 100,000 Hz, since a missed prefix moves any inductive reactance calculator answer by 1,000 times.

Inductance50 Hz60 Hz1 kHz100 kHz1 MHz10 MHz
1 µH314.2 µΩ377 µΩ6.283 mΩ628.3 mΩ6.283 Ω62.83 Ω
10 µH3.142 mΩ3.77 mΩ62.83 mΩ6.283 Ω62.83 Ω628.3 Ω
100 µH31.42 mΩ37.7 mΩ628.3 mΩ62.83 Ω628.3 Ω6.283 kΩ
1 mH314.2 mΩ377 mΩ6.283 Ω628.3 Ω6.283 kΩ62.83 kΩ
10 mH3.142 Ω3.77 Ω62.83 Ω6.283 kΩ62.83 kΩ628.3 kΩ
100 mH31.42 Ω37.7 Ω628.3 Ω62.83 kΩ628.3 kΩ6.283 MΩ
0.5 H157.1 Ω188.5 Ω3.142 kΩ314.2 kΩ3.142 MΩ31.42 MΩ
1 H314.2 Ω377 Ω6.283 kΩ628.3 kΩ6.283 MΩ62.83 MΩ

Every row climbs by exactly 100 times from 1 kHz to 100 kHz, and every column by 10 times per decade of inductance. That pattern makes any inductive reactance calculator answer easy to sanity-check by moving the decimal point.

In any inductive reactance calculator table, the 60 Hz column is always 20% above the 50 Hz one. A coil chosen for 60 Hz mains in North America therefore passes 20% more current on the 50 Hz mains used across Europe, Asia and Africa.

Each henry adds 2π ohms per hertz, so a 0.5 H coil gains 3.142 Ω for every hertz. Reaching 1 kΩ with that coil needs 318.3 Hz, a quick inductive reactance calculator check on any audio choke.

Coil Resistance, Impedance and Phase Angle

A 0.5 H coil with 10 Ω of winding resistance has 188.8 Ω of impedance at 60 Hz, not 188.5 Ω. Resistance and reactance add at right angles, so a small DCR barely changes Z when the inductive reactance calculator value for XL is large.

Z is the impedance in ohms, R is the coil's DC resistance, XL is the reactance and θ is the angle by which voltage leads current. An ideal coil with no resistance sits at exactly 90°, the angle a bare inductive reactance calculator result implies.

Coil, DCR, frequency, supplyXLZPhaseCurrentReactive power
0.5 H, 10 Ω, 60 Hz, 120 V188.5 Ω188.8 Ω86.96°635.7 mA76.18 VAR
0.5 H, 10 Ω, 50 Hz, 230 V157.1 Ω157.4 Ω86.36°1.461 A335.4 VAR
1 mH, 10 Ω, 1 kHz, 5 V6.283 Ω11.81 Ω32.14°423.4 mA1.126 VAR
10 mH, 10 Ω, 50 Hz, 12 V3.142 Ω10.48 Ω17.44°1.145 A4.118 VAR
100 µH, 0.2 Ω, 100 kHz, 12 V62.83 Ω62.83 Ω89.82°191 mA2.292 VAR

The 10 mH row is where the bare inductive reactance calculator figure misleads. At 50 Hz its 3.142 Ω is smaller than the 10 Ω winding, so the part behaves more like a resistor, drawing 1.145 A at a power factor of 0.954.

The 0.5 H coil on 120 V and 60 Hz dissipates only 4.041 W in its resistance while trading 76.18 VAR back and forth. Its power factor is 0.053, and 119.8 V of the 120 V appears across the reactance.

Coil resistance also sets the DC time constant τ = L ÷ R, which no inductive reactance calculator figure includes. The 0.5 H, 10 Ω coil takes 50 ms to reach 63% of its final current after switch-on, and about 250 ms, five time constants, to settle.

Working Backwards to Inductance or Frequency

To get 100 Ω of reactance at 60 Hz, a coil needs 265.3 mH; at 50 Hz it needs 318.3 mH. The same formula rearranges to give inductance from reactance, or the frequency at which a known coil reaches a target.

L is the inductance in henries, XL is the reactance in ohms and f is the frequency in hertz. In inductive reactance calculator terms, a 0.5 H coil reaches 100 Ω at 31.83 Hz, and a 10 mH coil reaches 1 kΩ at 15.92 kHz.

Inductance from current and voltage works the same way once V ÷ I gives the impedance. A coil drawing 636.6 mA from 120 V at 60 Hz has Z = 188.5 Ω, which is 500 mH if the winding resistance is ignored.

Measured V and IFrequencyDCRV ÷ IXLInductance
120 V, 636.6 mA60 Hz0 Ω188.5 Ω188.5 Ω500 mH
120 V, 636.6 mA60 Hz10 Ω188.5 Ω188.2 Ω499.3 mH
12 V, 100 mA50 Hz0 Ω120 Ω120 Ω382 mH
12 V, 100 mA50 Hz40 Ω120 Ω113.1 Ω360.1 mH
5 V, 20 mA1 kHz50 Ω250 Ω244.9 Ω38.98 mH

Skipping the winding resistance overstates the inductance in a reverse inductive reactance calculator check. In the 12 V row, ignoring a 40 Ω DCR gives 382 mH where the coil is really 360.1 mH, a 6% error that grows as DCR approaches V ÷ I.

The DCR comes from an ohmmeter reading on the bare coil. The reactance is then √(Z² - R²), the same right-angle rule used for impedance, run backwards.

Series and Parallel Inductor Reactance

Inductors in series add, so 10 mH, 22 mH and 47 mH make 79 mH and 29.78 Ω at 60 Hz. In parallel they combine like resistors: the same three give 5.998 mH and only 2.261 Ω.

10 mH, 22 mH and 47 mHTotal inductance50 Hz60 Hz1 kHz
In series79 mH24.82 Ω29.78 Ω496.4 Ω
In parallel5.998 mH1.884 Ω2.261 Ω37.68 Ω

Reactance follows the same rules as inductance, since every coil sees the same frequency. The series inductive reactance calculator total is just 2πf times the summed inductance.

In series the 47 mH part takes 59.5% of the voltage; in parallel the 10 mH part carries 60% of the current.

The reciprocal rule is the one in the Parallel Resistor Calculator, applied to henries or ohms of reactance. Two equal 1 mH coils give 2 mH in series and 500 µH in parallel.

These sums assume the coils are far enough apart that their magnetic fields do not couple. Coils wound on one core or side by side add mutual inductance.

That coupling can raise or lower any inductive reactance calculator total for the network, depending on which way each coil is wound, so a measured value beats the sum for coupled coils.

Resonance Partner: The Capacitor That Matches XL

A 14.07 µF capacitor has the same 188.5 Ω reactance at 60 Hz as a 0.5 H coil, so the pair resonates there. At 50 Hz the matching capacitor grows to 20.26 µF.

C is the capacitance in farads that makes XC equal XL, f is the frequency in hertz and L is the inductance in henries. At that point the two reactances cancel and only resistance limits the current.

Each part keeps its own inductive reactance calculator value of 188.5 Ω at 60 Hz in the 0.5 H case; they cancel only because one leads and the other lags.

Coil and frequencyXLCapacitor for XC = XLSusceptance BL
0.5 H at 50 Hz157.1 Ω20.26 µF6.366 mS
0.5 H at 60 Hz188.5 Ω14.07 µF5.305 mS
10 mH at 1 kHz62.83 Ω2.533 µF15.92 mS
100 µH at 100 kHz62.83 Ω25.33 nF15.92 mS
1 µH at 10 MHz62.83 Ω253.3 pF15.92 mS

Susceptance BL is 1 ÷ XL in siemens, the admittance form some inductive reactance calculator tables use. A coil with 62.83 Ω of reactance has 15.92 mS whatever its size or frequency.

Going the other way, a 0.5 H coil resonates at 225.1 Hz with 1 µF and at 711.8 Hz with 100 nF. The LC Resonant Frequency Calculator handles any pair, and capacitive reactance itself is in the Capacitor Impedance Calculator.

Self-Resonance and Q Beyond DC Resistance

XL = 2πfL only holds well below a coil's self-resonant frequency. Coilcraft's RF inductor guide advises an SRF at least 10 times the operating frequency, and notes that higher inductance values have lower SRFs.

Near the SRF, winding capacitance resonates with the inductance and impedance peaks; above it the coil acts like a capacitor.

An inductive reactance calculator result at 1 MHz or above is only valid if the datasheet SRF is 10 MHz or more.

Q from DC resistance is an upper limit. A 68 nH coil has 384.5 Ω of reactance at 900 MHz, and Coilcraft lists a wirewound 68 nH part at Q = 54, which implies about 7.1 Ω of loss resistance at that frequency.

A multilayer 68 nH part in the same Coilcraft table has Q = 20, or about 19.2 Ω of loss at 900 MHz. Coilcraft attributes the gap to skin effect and core losses, neither of which a DC ohmmeter can see.

At mains frequencies a Q based on DCR is close enough. The 0.5 H, 10 Ω coil gives Q = 18.85 at 60 Hz, and at that frequency skin effect in typical winding wire is small.

Reactance Questions With Worked Numbers

The same formula answers nearly every inductive reactance question, so each answer below runs it with real values rather than repeating the definition.

How do I calculate inductive reactance?

Multiply 2π by the frequency in hertz and the inductance in henries. A 14 mH coil at 100 Hz gives 2π × 100 × 0.014 = 8.796 Ω, and the result is always in ohms.

Convert prefixes first: mH ÷ 1,000 and µH ÷ 1,000,000 give henries, and kHz × 1,000 gives hertz. Most inductive reactance calculator mistakes are a missed prefix, which shifts the answer by 1,000.

How to calculate XL and XC?

XL = 2πfL for the inductive reactance calculator side and XC = 1 ÷ (2πfC) for capacitors. Inductive reactance rises with frequency while capacitive reactance falls, so they are the two types of reactance and work in opposite directions.

At 60 Hz, a 0.5 H coil gives XL = 188.5 Ω and a 14.07 µF capacitor gives XC = 188.5 Ω. In an RLC circuit the net reactance is XL - XC, which is zero for that pair.

What is the inductive reactance of a 0.5 H inductor operating at 60 Hz?

It is 188.5 Ω. The working is 2π × 60 × 0.5 = 188.5 Ω, and at 50 Hz the same coil has 157.1 Ω, the inductive reactance calculator figure for most of the world's mains.

A real 0.5 H choke with 10 Ω of winding resistance has 188.8 Ω of impedance at 60 Hz. On 120 V it draws 635.7 mA, with current lagging voltage by 86.96°.

When XL is equal to XC then?

The circuit is at resonance. The two reactances cancel, the impedance drops to the resistance alone in a series circuit, and current is in phase with voltage.

The frequency is f = 1 ÷ (2π√LC). A 0.5 H coil with 10 µF resonates at 71.18 Hz, and with 1 nF at 7.118 kHz. XL equals XC only at that one frequency.

What's the inductive reactance of a 20 mH inductor in an AC circuit with a frequency of 5000 Hz?

It is 628.3 Ω. The working is 2π × 5,000 × 0.02 = 628.3 Ω, about the same as a 1 mH coil at 100 kHz.

At 50 Hz the same 20 mH coil gives an inductive reactance calculator figure of only 6.283 Ω, 100 times less. That 100× drop matches the 100× drop in frequency.

How to calculate inductive impedance?

Combine the coil's resistance and reactance at right angles: Z = √(R² + XL²). For 10 Ω and 188.5 Ω, Z = 188.8 Ω at a phase angle of 86.96°.

Reactance is the imaginary part of impedance, written Z = R + jXL. The j marks the 90° shift between voltage and current, which is why XL and R cannot simply be added.

What are the units for inductive reactance?

Inductive reactance is measured in ohms (Ω), the SI unit of resistance and the output unit of every inductive reactance calculator, and its symbol is XL. Inductance itself is measured in henries (H).

The dimensional formula for reactance is the same as for resistance, M L2 T-3 A-2. Hertz times henries gives ohms, which is why 2πfL comes out in Ω.

What is inductive reactance for DC?

Inductive reactance at DC is 0 Ω, since f = 0. After the switch-on transient, only the winding resistance limits the current, so a 0.5 H, 10 Ω coil on 12 V DC settles at 1.2 A.

A coil with no resistance on DC would short the supply. The settling takes about five time constants, 5 × L ÷ R, which is 250 ms for the 0.5 H, 10 Ω coil.

How to calculate inductance in AC?

Measure the AC voltage and current, divide to get Z, remove the winding resistance, then divide by 2πf. A coil drawing 100 mA from 12 V at 50 Hz with 40 Ω DCR is 360.1 mH.

From a known reactance it is one step: L = XL ÷ 2πf. A coil needing 100 Ω at 60 Hz must be 265.3 mH, and at 1 kHz only 15.92 mH.

How to calculate inductive reactance in parallel?

Combine the reactances like parallel resistors: 1 ÷ XT = 1 ÷ X1 + 1 ÷ X2 + …. At 60 Hz, 10 mH, 22 mH and 47 mH in parallel give 2.261 Ω.

In series the reactances simply add, giving 29.78 Ω for the same three coils. Both answers assume no magnetic coupling between the coils.

How to measure inductive reactance?

Apply a known AC voltage at a known frequency, measure the current and compute V ÷ I, then remove the DC resistance. An LCR meter measures inductance directly, and XL follows from 2πfL.

Measure at the frequency the coil will work at, not the one an inductive reactance calculator example happens to use. Iron and ferrite cores change inductance with frequency and current, so a 1 kHz bench reading may not match the coil at 50 kHz.

What is the difference between inductive reactance and inductance?

Inductance in henries is a fixed property of the coil; inductive reactance in ohms is how much that coil opposes AC at one frequency. A 0.5 H coil is 0.5 H at any frequency, but 157.1 Ω at 50 Hz and 3.142 kΩ at 1 kHz.

In simple terms, inductance is the coil's size and reactance is its effect on a given signal. The Coil Inductance Calculator estimates the henries from a coil's turns and dimensions.

What is inductor reactance calculator?

It is a 2πfL conversion between inductance, frequency and the ohms of AC opposition that result. Winding resistance, impedance, phase and current complete a full inductive reactance calculator answer.

For a color-banded part, the value comes first from its markings, which the Inductor Color Code Calculator reads, before the reactance can be worked out.

How do you calculate reactance in a magnetic inductor?

Use 2πfL with the inductance at the actual operating current. Iron and ferrite cores lose inductance as they approach saturation, so XL falls with current even at a fixed frequency.

Datasheets give a saturation current where inductance has dropped by a stated amount, a limit outside any inductive reactance calculator formula.

Below that current the rated value holds; above it, a 0.5 H coil may act like much less, and its reactance drops in the same ratio.

What is the difference between self-resonant frequency (SRF) and inductive reactance?

Inductive reactance is the ideal 2πfL opposition; SRF is the frequency where winding capacitance resonates with the coil. Below the SRF reactance rises with frequency, and above it the coil turns capacitive.

Coilcraft's rule is an SRF at least 10 times the working frequency. A choke used at 1 MHz therefore needs an SRF of 10 MHz or higher for 2πfL to hold.

Can I use this calculator to determine the reactance of a transformer winding?

Only for the winding alone, with the other windings open. Measure that winding's inductance first, then apply 2πfL; a 1 H primary has 314.2 Ω at 50 Hz and 377 Ω at 60 Hz.

Once a load is connected, the secondary reflects into the primary and the winding no longer behaves as a simple inductor. Leakage inductance and the core's magnetising current then set the behaviour instead.