Roof Panel Length Calculator for metal panels on gable, hip and shed roofs from width, pitch and overhangs, with hip cut lengths, panel counts, the trim, closures and screw counts.
Measure the walls, then add the eave overhang. Panels run ridge to eave.
Drip Overhang and Ridge Gap
Panels usually run 1 to 2 in past the drip edge. Leave a gap at the ridge for the vent and closure strip.
Panel Count, Screws and Coverage
Exposed-fastener panels cover 36 in; standing seam 12 to 18 in. R-panels take about 4 screws per line, lines 24 in apart.
Panel Length Diagram
Panel Length Chart by Pitch
| Pitch | Angle | Slope Length | Panel Length |
|---|---|---|---|
| 1/12 | 4.76° | 13 ft 9/16 in | 13 ft 1 9/16 in |
| 2/12 | 9.46° | 13 ft 2 1/8 in | 13 ft 3 1/8 in |
| 3/12 | 14.04° | 13 ft 4 13/16 in | 13 ft 5 13/16 in |
| 4/12 | 18.43° | 13 ft 8 7/16 in | 13 ft 9 7/16 in |
| 5/12 | 22.62° | 14 ft 1 in | 14 ft 2 in |
| 6/12 (yours) | 26.57° | 14 ft 6 7/16 in | 14 ft 7 7/16 in |
| 7/12 | 30.26° | 15 ft 5/8 in | 15 ft 1 5/8 in |
| 8/12 | 33.69° | 15 ft 7 1/2 in | 15 ft 8 1/2 in |
| 9/12 | 36.87° | 16 ft 3 in | 16 ft 4 in |
| 10/12 | 39.81° | 16 ft 11 1/16 in | 17 ft 1/16 in |
| 11/12 | 42.51° | 17 ft 7 5/8 in | 17 ft 8 5/8 in |
| 12/12 | 45.00° | 18 ft 4 5/8 in | 18 ft 5 5/8 in |
| 14/12 | 49.40° | 19 ft 11 11/16 in | 20 ft 11/16 in |
| 16/12 | 53.13° | 21 ft 8 in | 21 ft 9 in |
Material Order List
| Item | Order | Based On |
|---|---|---|
| Panels cut to 14 ft 7 1/2 in | 28 pcs | Eave to ridge |
| Extra panels for waste | 3 pcs | 10% at 14 ft 7 1/2 in |
| Ridge cap | 42 linear ft | Roof length with rakes |
| Eave trim | 84 linear ft | Both eaves |
| Rake trim | 58 linear ft | 4 rakes of 14 ft 6 7/16 in |
| Inside closures | 28 pcs | One per panel at the eave |
| Outside closures | 28 pcs | One per panel at the ridge |
| Panel screws | 1,008 | 4 per line, lines every 24 in |
| Trim screws | 185 | One per linear foot of trim |
Step-by-Step Math
- Slope factor: √(1 + 0.5²) = 1.11803 (6/12, 26.565°)
- Run per side: 24 ÷ 2 = 12 ft
- Panel length: (12 + 1) × 1.11803 + 0.1667 - 0.0833 = 14.6178 ft
- Panels: ⌈(40 + 2 × 1) ÷ 3⌉ = 14 × 2 × 1.1 → 31
- Coverage: 453.151 total panel length × 3 = 1,359 sq ft
- Panel screws: per panel (⌈length ÷ 2⌉ + 1) lines × 4, summed = 1,008
Slope Length, Overhang and Ridge Gap in a Roof Panel Length Calculator
A metal roof panel is the sloped run from ridge to eave, plus the eave overhang along the slope and the drip past the trim, minus a small gap at the ridge. A 24 ft wide gable at 6/12 needs panels 14 ft 7 7/16 in long.
L is panel length, R the level run from wall to ridge (half the width on a gable, the full width on a shed), and O the level eave overhang. P is the pitch per 12, D the drip past the eave trim and G the ridge gap.
The square root term is the slope factor in roof panel length calculator math. At 6/12 it is 1.11803, so the 12 ft run plus a 12 in overhang becomes 13 ft × 1.11803 = 14 ft 6 7/16 in along the roof, the length a tape reads from peak to fascia.
The drip and ridge gap are small but real. A 2 in drip and 1 in ridge gap net 1 in more, so the roof panel length calculator figure in inches is 175 7/16 in for ordering.
Metric roof panel length calculator orders work the same way. That panel is 4.455 m, and rounding up to the next 10 mm gives an order length of 4,460 mm for suppliers who cut by the centimeter.
Panel Length Chart by Building Width and Pitch
Panel length grows with both width and pitch in a roof panel length calculator chart, and steep roofs gain fast. A 24 ft gable needs 13 ft 3 1/8 in panels at 2/12 but 18 ft 5 5/8 in at 12/12, assuming a 12 in eave, 2 in drip and 1 in ridge gap.
| Gable width | 2/12 | 3/12 | 4/12 | 6/12 | 8/12 | 12/12 |
|---|---|---|---|---|---|---|
| 16 ft | 9 ft 2 1/2 in | 9 ft 4 5/16 in | 9 ft 6 13/16 in | 10 ft 1 3/4 in | 10 ft 10 13/16 in | 12 ft 9 3/4 in |
| 20 ft | 11 ft 2 13/16 in | 11 ft 5 1/16 in | 11 ft 8 1/8 in | 12 ft 4 9/16 in | 13 ft 3 5/8 in | 15 ft 7 11/16 in |
| 24 ft | 13 ft 3 1/8 in | 13 ft 5 13/16 in | 13 ft 9 7/16 in | 14 ft 7 7/16 in | 15 ft 8 1/2 in | 18 ft 5 5/8 in |
| 30 ft | 16 ft 3 5/8 in | 16 ft 6 15/16 in | 16 ft 11 3/8 in | 17 ft 11 11/16 in | 19 ft 3 3/4 in | 22 ft 8 1/2 in |
| 36 ft | 19 ft 4 1/8 in | 19 ft 8 in | 20 ft 1 5/16 in | 21 ft 3 15/16 in | 22 ft 11 in | 26 ft 11 7/16 in |
| 40 ft | 21 ft 4 1/2 in | 21 ft 8 3/4 in | 22 ft 2 5/8 in | 23 ft 6 3/4 in | 25 ft 3 7/8 in | 29 ft 9 3/8 in |
A shed roof uses the full width as its run in a roof panel length calculator estimate. A 12 ft deep lean-to at 3/12 takes the same 13 ft 5 13/16 in panel as a 24 ft gable at 3/12, because both slopes run 12 ft from low edge to high edge.
The slope length to the wall line matches the common rafter, so a Rafter Length Calculator result is a quick cross-check. For the 24 ft, 6/12 roof both read 13 ft 5 in before overhang.
Metal Roof Overhang Length Chart
In a roof panel length calculator, overhang measured level grows once it follows the slope. A 12 in level eave adds 13 7/16 in of panel at 6/12 and 17 in at 12/12, so measuring overhang along the roof and treating it as level shorts the panel.
| Level overhang | 3/12 | 4/12 | 6/12 | 8/12 | 12/12 |
|---|---|---|---|---|---|
| 6 in | 6 3/16 in | 6 5/16 in | 6 11/16 in | 7 3/16 in | 8 1/2 in |
| 12 in | 12 3/8 in | 12 5/8 in | 13 7/16 in | 14 7/16 in | 17 in |
| 18 in | 18 9/16 in | 19 in | 20 1/8 in | 21 5/8 in | 25 7/16 in |
| 24 in | 24 3/4 in | 25 5/16 in | 26 13/16 in | 28 7/8 in | 33 15/16 in |
Beyond the fascia, panels hang past the eave trim so water drips clear of it. Builder Aaron Miiller sets his panels to overhang the eave trim by 1 1/2 in in his JLC guide to exposed-fastener reroofing.
A 1 to 2 in drip is the common range, so a roof panel length calculator drip of 2 in sits at its long end. Trim length along the eave and rakes is a separate count, worked out in the Drip Edge Calculator.
Cut-to-Length Versus Stock Panel Lengths
Cut-to-length panels waste almost nothing, while stock lengths can waste over a foot per panel. The 14 ft 7 7/16 in panel above, bought as 16 ft stock, loses 16 9/16 in on each of 31 panels, or 42.8 linear ft.
Ordered cut to the next 1/2 in from the roof panel length calculator figure, the same panel is 14 ft 7 1/2 in and the scrap shrinks to under 1/8 in per panel.
Most metal roofing suppliers roll-form exposed-fastener and standing seam panels to the exact length you order, so stock sizes only matter at a retail counter.
Retail stores stock ribbed panels in a few set lengths, such as 12 ft Union Corrugating Master Rib. A steel roof panel length calculator figure over the longest stock size means an end lap or a custom order.
Run the roof panel length calculator math backward and stock panels cap the building width a single sheet can cover. At 6/12 with a 12 in eave, a 12 ft panel spans a gable up to 19 ft 3 13/16 in wide and a 16 ft panel up to 26 ft 5 11/16 in.
End laps need a purlin under the joint and sealant between the sheets. Every lap adds a leak path, so buy each panel in one piece whenever the supplier allows.
Coverage Width, Panel Count and Square Feet
Panel count in roof panel length calculator math is the eave length, rakes included, divided by net coverage width and rounded up per slope. A 40 ft gable with 12 in rakes takes 14 panels per slope at 36 in coverage but 32 with 16 in standing seam.
| Coverage width | Typical panel | Panels per slope (42 ft eave) | Both slopes | With 10% extra |
|---|---|---|---|---|
| 36 in | Exposed-fastener rib | 14 | 28 | 31 |
| 24 in | 5V crimp | 21 | 42 | 47 |
| 18 in | Standing seam | 28 | 56 | 62 |
| 16 in | Standing seam | 32 | 64 | 71 |
| 12 in | Standing seam | 42 | 84 | 93 |
Coverage is the net width after the side lap, not the sheet width, and mixing the two trips up many metal roofing sheet size calculator estimates.
A 38 in wide rib panel laps one rib and covers 36 in, so dividing by 38 in would leave the roof one panel short per slope.
A 10% allowance suits roofs with hips and valleys, but a plain gable cut to length needs no roof panel length calculator allowance beyond the last partial panel.
Here the 42 ft eave takes exactly 14 panels at 36 in per slope, so 28 panels finish the roof and the 3 extra from a 10% allowance sit unused.
In square feet, the roof surface with 12 in rakes is 1,221 sq ft, or 12.21 squares. Thirty-one panels cover 1,359 sq ft, and the Metal Roof Cost Calculator prices that metal roofing material by the panel.
Roof square footage from footprint and pitch is also in the Gable Roof Area Calculator, a quick check on any roof sq ft figure before pricing panels.
Hip Roof Panel Cut List
A 24 × 40 ft hip roof at 6/12 with 12 in eaves takes 14 full-length panels and 32 cut panels in 8 lengths, 46 in all. The same footprint as a gable needs only 28 panels, all one length.
In a roof panel length calculator cut list, each panel along a hip face is cut to its longest edge, where its far side meets the hip line.
With equal pitches the hip runs at 45 degrees in plan, so a panel's run grows by one coverage width for each step in from the corner, until it reaches the full ridge-to-eave run.
| Order length | Pieces | Where it goes |
|---|---|---|
| 14 ft 7 1/2 in | 14 | Eave to ridge, long faces |
| 13 ft 7 in | 6 | Eave to hip line |
| 12 ft 6 in | 2 | Eave to hip line |
| 10 ft 3 in | 6 | Eave to hip line |
| 9 ft 1 1/2 in | 2 | Eave to hip line |
| 6 ft 10 1/2 in | 6 | Eave to hip line |
| 5 ft 9 1/2 in | 2 | Eave to hip line |
| 3 ft 6 1/2 in | 6 | Eave to hip line |
| 2 ft 5 in | 2 | Eave to hip line |
Hip panels raise the roof panel length calculator total as well as the count. The cut list totals about 469 linear ft against 409 ft for the gable, because each cut panel is ordered to its long edge and the triangle beyond the hip line is scrap.
A cut list grouped this way lets the supplier roll-form each length once. Roof area by face for the same hip roof is in the Hip Roof Calculator, and valleys on L- or T-shaped roofs need their own cut layout.
Trim, Closures and Screw Counts
A 24 × 40 ft gable at 6/12 needs about 1,008 panel screws and 185 trim screws, plus 184 linear ft of trim. Those counts follow the Western States Metal Roofing screw guide.
That guide uses screw lines 24 in apart on solid decking, with three panel screws and one lap screw per line on interior R-panels. Trim gets one screw per linear foot, and its rule of thumb is 80 screws per 100 sq ft.
| Item | 24 × 40 ft gable, 6/12 | 24 × 40 ft hip, 6/12 | 12 × 20 ft shed, 3/12 |
|---|---|---|---|
| Panels, no waste | 28 | 46 | 8 |
| Ridge cap | 42 linear ft | 16 linear ft | 0 |
| Hip cap | 0 | 78 linear ft | 0 |
| Eave trim | 84 linear ft | 136 linear ft | 22 linear ft |
| Rake trim | 58.1 linear ft | 0 | 26.8 linear ft |
| High-side trim | 0 | 0 | 22 linear ft |
| Inside closures | 28 | 46 | 8 |
| Outside closures | 28 | 14 | 8 |
| Panel screws | 1,008 | 1,224 | 256 |
| Trim screws | 185 | 230 | 71 |
Counting screws line by line beats the square-foot rule on cut roofs. The gable lands at 83 screws per 100 sq ft, close to the 977 that the 80-per-square rule gives.
The hip needs 1,224, about 100 per 100 sq ft, because every short hip panel in a roof panel length calculator cut list still gets screws at both ends.
Line spacing moves the count most. The guide puts closer spacing at 18 in and allows up to 36 in on solid wood, so check the panel maker's fastening schedule before a roof panel length calculator count goes on the order.
Minimum Pitch by Metal Panel Type
Lapped exposed-fastener panels need at least 3/12 without sealant, 1/2 in 12 with lap sealant, and standing seam at least 1/4 in 12. These limits come from IBC Section 1507.4.2, as MBCI summarizes.
| Pitch | 24 ft gable panel | 30 ft shed panel | Panel types allowed |
|---|---|---|---|
| 1/4 in 12 | 13 ft 1 1/16 in | 31 ft 1 1/16 in | Standing seam |
| 1/2 in 12 | 13 ft 1 1/8 in | 31 ft 1 5/16 in | Standing seam, or lapped with sealant |
| 1 in 12 | 13 ft 1 9/16 in | 31 ft 2 5/16 in | Standing seam, or lapped with sealant |
| 3/12 | 13 ft 5 13/16 in | 32 ft 7/16 in | All metal panels |
Low pitch barely changes the roof panel length calculator result, so the choice is about leaks, not material. A 30 ft shed at 1/4 in 12 needs a 31 ft 1 1/16 in panel, a length only a cut-to-length standing seam order delivers in one piece.
Check the exact pitch before trusting a roof panel length calculator order, since a roof built at 2 3/4 in 12 instead of 3/12 drops below the no-sealant limit. The Roof Pitch Calculator turns a measured rise and run into pitch.
Measuring Before You Order Panels
Roof panel length calculator figures below assume a 12 in level eave, 2 in drip and 1 in ridge gap unless a question says otherwise. Measurements taken on the roof override any plan dimension.
What is a metal roof panel length calculator?
It is a sizing aid that converts building width, pitch and overhang into the cut length of each ridge-to-eave panel. Roof panel length is that cut length, the long dimension of a sheet running down the slope.
A good estimate also counts panels from the coverage width and roof length. For a 24 × 40 ft gable at 6/12 with 36 in panels, that is 28 panels at 14 ft 7 7/16 in, about 409 linear ft of panel.
How do you measure a roof panel?
Tape straight down the slope from the ridge peak to the fascia edge, then add the drip and subtract the ridge gap. A 14 ft 6 7/16 in tape reading with a 2 in drip and 1 in gap gives a 14 ft 7 7/16 in panel.
Measure at both gable ends and the middle, because framing is rarely square, and order to the longest reading. Without roof access, work it from the run and pitch, which is how roof length along the slope is calculated.