High Pass Filter Calculator

Updated

High pass filter calculator for RC, RL, LC, Sallen-Key, op-amp and tweeter crossover circuits. Solves the cutoff or a part value, then gives gain, phase, Q and DC step settle time.

High-Pass Filter

Series capacitor, resistor to ground. A first-order RC high-pass filter cuts off at fc = 1 ÷ (2πRC).

Ω
Test Signal & Stages--
V/V
1.026 kHz Cutoff Frequency
fc = 1 ÷ (2π × 3.3 kΩ × 47 nF)
956.5 mV Out at 200 Hz
Gain-14.4 dB
Phase Shift78.97°
What happens to your test signal: the output level, the gain in dB and the phase lead.
17.25 kΩ Input Impedance
Output Impedance3.239 kΩ
Input Current289.9 µA
At the test frequency: what the source drives and what feeds the load.
357.1 µs Step Fades to 10%
Time Constant (τ = RC)155.1 µs
Settles Within 1% After714.2 µs
A sudden DC step passes at once, then fades away; this is how long DC takes to block.
+20 dB/decade Below Cutoff
Frequency for -40 dB10.26 Hz
Loss at fc ÷ 2-6.99 dB
Below the cutoff the output drops by this much for every tenfold fall in frequency.
Bode Plot of the Filter+20 dB/decade below fc
10-10-30-50-70-9010.26 Hz102.6 Hz1.026 kHz10.26 kHz102.6 kHzfc 1.026 kHz, -3.01 dBtest -14.4 dBGain (dB)
Gain and Phase Across Frequencies10.26 Hz to 10.26 kHz
PointFrequencyGainOutputPhase
fc ÷ 10010.26 Hz-40 dB50 mV89.43°
fc ÷ 10102.6 Hz-20 dB497.5 mV84.29°
Test signal200 Hz-14.4 dB956.5 mV78.97°
fc ÷ 2513.1 Hz-6.99 dB2.236 V63.43°
fc1.026 kHz-3.01 dB3.536 V45°
2 × fc2.052 kHz-0.969 dB4.472 V26.57°
10 × fc10.26 kHz-0.0432 dB4.975 V5.711°
Step-by-Step Math5 steps
1. Time Constantτ = R × C = 3,300 Ω × 0.000000047 F = 155.1 µs
2. Cutoff Frequencyf = 1 ÷ (2π × 0.0001551 s) = 1.026 kHz
3. Gain at Test Signal|H| = (0.1949² ÷ (1 + 0.1949²))^(1/2) = 0.1913 (-14.4 dB)
4. Output5 V × 0.1913 = 956.5 mV
5. Result1.026 kHz Cutoff Frequency
Test Signal Is Blocked
200 Hz is below the 1.026 kHz cutoff, so it comes out -14.4 dB below the passband level.

RC High Pass Filter Calculator: Cutoff, Capacitor and Resistor

A series capacitor with a resistor to ground passes high frequencies and blocks low ones. The cutoff sits where the capacitor's reactance equals the resistance, and the output there is 70.7% of the input.

Here fc is the cutoff in hertz, R is the resistance to ground in ohms and C is the series capacitance in farads. Any RC high pass filter calculator result traces back to this one line.

That is the same equation solved for the capacitor. Solve for the resistor the same way, with C in place of R. Both forms give the -3 dB point, not the frequency where blocking begins.

Take 3.3 kΩ and 47 nF. The time constant RC is 155.1 µs, so fc = 1 ÷ (2π × 155.1 µs) = 1.026 kHz. A 5 V, 200 Hz tone comes out at 0.957 V, 14.4 dB down, with a 79.0° phase lead.

Source resistance adds to R in every high pass filter calculator sum. Feed the same 3.3 kΩ and 47 nF from a 600 Ω output and the cutoff drops to 868.3 Hz, with a 1.45 dB divider loss in the passband. A 50 Ω source moves it only to 1.011 kHz.

When solving for R, subtract the source. For 1 kHz with 47 nF behind 600 Ω, R is 2.786 kΩ, not 3.386 kΩ. A source above 3.386 kΩ cannot reach a 1 kHz cutoff with that capacitor at all.

PointFor the 1.026 kHz filterGainOutput vs inputPhase lead
fc ÷ 10010.26 Hz-40.0 dB1.0%89.4°
fc ÷ 10102.6 Hz-20.0 dB9.95%84.3°
fc ÷ 4256.5 Hz-12.3 dB24.3%76.0°
fc ÷ 2513.1 Hz-6.99 dB44.7%63.4°
fc1.026 kHz-3.01 dB70.7%45.0°
2 × fc2.052 kHz-0.97 dB89.4%26.6°
10 × fc10.26 kHz-0.04 dB99.5%5.7°

The gain, output and phase columns hold for any first-order RC or RL filter, since only the ratio f ÷ fc matters. Multiply the first column by your own cutoff to reuse the table with any high pass filter calculator result.

Many people treat the cutoff as the edge of a flat passband. It is not: the signal is still 1 dB down at 1.97 × fc and only within 0.1 dB above 6.55 × fc. Set any high pass filter calculator cutoff with that margin below the band you need to keep.

Standard Part Values for Common Cutoff Frequencies

Exact capacitor values from a high pass filter calculator are rarely stocked. E12 steps sit about 20% apart, so the stock part on the wrong side can move the cutoff by up to 18%. Every row uses 10 kΩ to ground.

Target cutoffExact CE12 belowCutoff with itE12 aboveCutoff with it
20 Hz795.8 nF680 nF23.41 Hz820 nF19.41 Hz
50 Hz318.3 nF270 nF58.95 Hz330 nF48.23 Hz
80 Hz198.9 nF180 nF88.42 Hz220 nF72.34 Hz
100 Hz159.2 nF150 nF106.1 Hz180 nF88.42 Hz
300 Hz53.05 nF47 nF338.6 Hz56 nF284.2 Hz
3 kHz5.305 nF4.7 nF3.386 kHz5.6 nF2.842 kHz
10 kHz1.592 nF1.5 nF10.61 kHz1.8 nF8.842 kHz

Round the capacitor up when the band above must survive, as with a subsonic filter: 820 nF puts a 20 Hz target at 19.41 Hz. Round it down when the noise below must go, as with 50 Hz hum: 270 nF lifts the cutoff to 58.95 Hz.

The cutoff scales inversely with C, so a ±10% capacitor shifts a high pass filter calculator cutoff by about ±10%. A ±5% film capacitor halves that error, which matters more than the E12 rounding near a hum frequency.

Audio High Pass Filter Calculator Values: Choosing R and C

In audio, R is usually the input impedance of the next stage, so only C is left to choose. A coupling capacitor and that input form the high-pass filter whether you meant one or not.

Input impedance100 nF470 nF1 µF4.7 µF
10 kΩ159.2 Hz33.86 Hz15.92 Hz3.386 Hz
22 kΩ72.34 Hz15.39 Hz7.234 Hz1.539 Hz
47 kΩ33.86 Hz7.205 Hz3.386 Hz0.721 Hz
100 kΩ15.92 Hz3.386 Hz1.592 Hz0.339 Hz
1 MΩ1.592 Hz0.339 Hz0.159 Hz0.034 Hz

A high pass filter calculator cutoff right at 20 Hz costs 3 dB at 20 Hz. To lose under 0.5 dB there, keep the cutoff at or below 6.99 Hz; under 0.1 dB needs 3.05 Hz or lower. So 1 µF into 10 kΩ loses 2.13 dB at 20 Hz, while 4.7 µF loses only 0.12 dB.

A bigger capacitor also slows recovery from DC steps such as turn-on offset. With 1 µF into 10 kΩ, the time constant is 10 ms: a step fades to 10% in 23 ms and to 1% in 46 ms. Into 1 MΩ, the same capacitor takes 4.6 s to settle.

That trade sets most audio high pass filter calculator choices. Size C for the bass you must keep, then confirm the settling time will not cause a thump or slow recovery after clipping.

RL High-Pass Filters and Source Resistance

A series resistor with an inductor to ground also makes a first-order high-pass filter. Its cutoff falls where the inductor's reactance ωL equals R.

R is the total series resistance in ohms and L is the inductance in henries. This is the exact -3 dB point of the circuit, not a rough estimate, and the time constant is L ÷ R.

With 330 Ω and 10 mH, fc = 330 ÷ (2π × 0.01) = 5.252 kHz and the time constant is 30.3 µs. A 50 Ω signal generator adds to the 330 Ω in the high pass filter calculator math, raising the cutoff 15% to 6.048 kHz.

Target cutoffL with 100 ΩL with 1 kΩ
300 Hz53.05 mH530.5 mH
1 kHz15.92 mH159.2 mH
3 kHz5.305 mH53.05 mH

A 530.5 mH coil for a 300 Hz cutoff is large and lossy, which is why RC wins at audio frequencies. An RL high pass filter calculator answer makes most sense in low-impedance or RF paths where the inductor is small.

LC High Pass Filter Calculator Results Shift With the Load

A series capacitor and shunt inductor roll off at 40 dB per decade. The -3 dB point equals the resonant frequency only when the load sets Q to 0.707.

f0 is the natural frequency, RL is the load across the inductor and √(L ÷ C) is the characteristic impedance. With 47 nF and 100 mH, f0 is 2.322 kHz and √(L ÷ C) is 1,459 Ω.

LoadQ-3 dB cutoffPeak above passband
470 Ω0.3226.467 kHzNone
1 kΩ0.6862.397 kHzNone
1.459 kΩ1.001.825 kHz+1.25 dB at 3.282 kHz
2.2 kΩ1.511.622 kHz+4.08 dB at 2.628 kHz
4.7 kΩ3.221.520 kHz+10.3 dB at 2.380 kHz
10 kΩ6.861.500 kHz+16.7 dB at 2.334 kHz

The same two parts give a cutoff anywhere from 1.5 to 6.5 kHz. Plug only L and C into an LC high pass filter calculator formula and every row reads 2.322 kHz; five of the six are more than 20% off.

Source resistance moves it again. Feed the 1 kΩ case from 600 Ω and the natural frequency drops to 1.835 kHz, Q falls to 0.676, the cutoff lands at 1.922 kHz and the passband sits 4.08 dB down.

Speaker High Pass Filter Calculator Values for Tweeters

A tweeter needs a series capacitor for 6 dB per octave, plus a shunt inductor across its terminals for 12 dB per octave. The Q of the pair sets the alignment: 0.707 for Butterworth, 0.5 for Linkwitz-Riley.

f is the crossover frequency and Z is the tweeter impedance. These reduce to the constants in Rod Elliott's passive crossover article: 0.0796 ÷ (Zf) and 0.3183Z ÷ f for Linkwitz-Riley, with 0.1125 and 0.2251 for Butterworth.

ZCrossover1st order CButterworth CButterworth LLinkwitz-Riley CLinkwitz-Riley L
8 Ω2 kHz9.947 µF7.034 µF0.900 mH4.974 µF1.273 mH
8 Ω2.5 kHz7.958 µF5.627 µF0.720 mH3.979 µF1.019 mH
8 Ω3 kHz6.631 µF4.689 µF0.600 mH3.316 µF0.849 mH
8 Ω3.5 kHz5.684 µF4.019 µF0.515 mH2.842 µF0.728 mH
8 Ω4 kHz4.974 µF3.517 µF0.450 mH2.487 µF0.637 mH
4 Ω2 kHz19.89 µF14.07 µF0.450 mH9.947 µF0.637 mH
4 Ω2.5 kHz15.92 µF11.25 µF0.360 mH7.958 µF0.509 mH
4 Ω3 kHz13.26 µF9.378 µF0.300 mH6.631 µF0.424 mH
4 Ω3.5 kHz11.37 µF8.039 µF0.257 mH5.684 µF0.364 mH
4 Ω4 kHz9.947 µF7.034 µF0.225 mH4.974 µF0.318 mH

First-order and Butterworth sections are 3.01 dB down at the crossover point. A Linkwitz-Riley section is 6.02 dB down there and reaches its own -3 dB point higher, at 1.554 times the crossover frequency.

Wire the tweeter with reversed polarity on any 12 dB section. Elliott warns that skipping it leaves a deep notch at the crossover, and Linkwitz Lab notes the two LR2 outputs sit 180° apart at every frequency.

Elliott advises sizing parts from the impedance measured at the crossover frequency, not the label. Put that measured figure into the high pass filter calculator sum, because the result moves a lot.

Butterworth parts for 8 Ω at 3 kHz on a tweeter that reads 6 Ω give Q 0.530 and a cutoff of 4.29 kHz. On 12 Ω they give Q 1.06, a 2.30 kHz cutoff and a 1.6 dB bump.

Sallen-Key High Pass Filter Calculator Design

A Sallen-Key high-pass uses two series capacitors, one resistor from their junction back to the op-amp output and one from the op-amp input to ground. It gives 40 dB per decade with no inductor.

Here R1 is the feedback resistor to the output, R2 the resistor to ground and K the passband gain. Texas Instruments' Sallen-Key analysis (SLOA024B) swaps the two resistor names, so match parts by position, not label.

At unity gain with equal capacitors, Q = √(R2 ÷ R1) ÷ 2. A Butterworth response therefore needs the ground resistor at twice the feedback resistor. For 1 kHz with 10 nF, that is 11.25 kΩ and 22.51 kΩ.

Stock 10 kΩ and 22 kΩ parts give f0 = 1.073 kHz and Q = 0.742, a -3 dB point of 1.025 kHz and a 0.04 dB rise. That small error is why a 2nd order high pass filter calculator answer should list Q, not just the cutoff.

Gain KQ-3 dB cutoffPeak above passbandLevel at 1.592 kHz
1.0000.5002.473 kHzNone-6.02 dB
1.5860.7071.591 kHzNone+0.99 dB
2.0001.001.251 kHz+1.25 dB+6.02 dB
2.5002.001.072 kHz+6.30 dB+14.0 dB
2.90010.01.026 kHz+20.0 dB+29.2 dB
3.000InfiniteOscillates--

The table uses equal parts, 10 kΩ and 10 nF, where Q = 1 ÷ (3 - K). TI states that K = 3 drives Q to infinity, and gain above that makes the circuit oscillate.

Op-Amp Gain and the Upper Band Edge

An active high-pass filter is really a band-pass. The op-amp's gain-bandwidth product divided by the noise gain sets an upper -3 dB edge, and high gain pulls it into the audio band.

The cutoff still follows 1 ÷ (2π × Ri × C). In the inverting form, C sits in series with Ri and the gain is -Rf ÷ Ri.

In the non-inverting form, C feeds Ri to ground and the gain is 1 + Rf ÷ Rg, as in any Non-Inverting Op-Amp Resistor Calculator setup.

CircuitGainGBWLow -3 dBHigh -3 dB
Non-inverting, 100 kΩ, 100 nF10 (20 dB)1 MHz15.92 Hz100 kHz
Non-inverting, 100 kΩ, 100 nF100 (40 dB)1 MHz15.92 Hz10 kHz
Non-inverting, 100 kΩ, 100 nF100 (40 dB)10 MHz15.92 Hz100 kHz
Inverting, 10 kΩ, 1 µF, Rf 100 kΩ-10 (20 dB)1 MHz15.92 Hz90.91 kHz

A 40 dB stage on a 1 MHz part stops at 10 kHz and cuts the top of the audio band, a limit no plain high pass filter calculator cutoff reveals.

The inverting stage tops out lower than the non-inverting one at the same 20 dB, because its noise gain is 1 + Rf ÷ Ri, or 11.

Push the gain further and the passband can vanish. A 10 kHz non-inverting stage with a gain of 100 on a 1 MHz part has its op-amp corner at 10 kHz too. Its response peaks at 34.0 dB, 6.02 dB short of the 40 dB target, with no -3 dB passband.

Check gain alone with the Op Amp Gain Calculator. When the upper edge must be set on purpose, size both corners with the Bandpass Filter Calculator.

Stacking Stages for 3rd and 4th Order Roll-Off

Each identical buffered RC stage adds 20 dB per decade to the 1st order high pass filter calculator slope, but the overall -3 dB point climbs above each stage's own cutoff. For a set overall cutoff, every stage must sit lower.

f0 is the cutoff of one stage, N is the number of equal stages and fc is the overall -3 dB point. Two stages at 643.6 Hz each give 1 kHz overall.

Equal stagesEach stage for 1 kHz overallLoss at 500 HzLoss at 100 HzStep undershoot
11.000 kHz-6.99 dB-20.0 dB0%
2643.6 Hz-8.49 dB-32.6 dB13.5%
3509.8 Hz-9.29 dB-42.9 dB20.6%
4435.0 Hz-9.79 dB-52.0 dB24.7%

Equal stages give a soft knee. A 3rd order Butterworth reaches -18.1 dB at 500 Hz and -60.0 dB at 100 Hz, so anyone after a 3rd order high pass filter calculator for a sharp corner needs a first-order section plus a Q = 1 section, not three copies.

Two equal buffered stages match a Linkwitz-Riley second-order response exactly. Joined without buffers, the second stage loads the first: Q falls to 1/3 and the cutoff lands at 2.67 times the single-stage value instead of 1.55.

Cutoff Point, Filter Type and Part Choices

Two numbers settle most high pass filter calculator questions: the cutoff, and the order. Each order adds 20 dB per decade to how fast the signal falls below the cutoff.

What is a high-pass filter?

A high-pass filter passes frequencies above its cutoff and attenuates those below. A first-order one loses 6 dB per octave below the cutoff, and it blocks DC completely.

Below the cutoff, the signal shrinks and its phase leads by up to 90°. Put 50 Hz hum under a 500 Hz first-order cutoff and it drops to about 10% (-20.0 dB); a 2nd-order Butterworth at 500 Hz drops it to 1% (-40.0 dB).

How do I use a high pass filter calculator?

Fix the circuit type first: RC for most signal work, RL where an inductor already sits in the path, LC or Sallen-Key when you need 12 dB per octave. Then use the two values you know to solve for the third.

The cutoff and the resistance set by the next stage are the usual knowns. Round the high pass filter calculator result to a stock part and recompute the cutoff with that part.

Then check the level at the frequency you care about, not only the cutoff. A 60 Hz hum through a 1.026 kHz first-order filter comes out 24.7 dB down.

How do I tell a high-pass filter from a low-pass filter?

Look at which part is in series. A series capacitor with a resistor to ground is high-pass; a series resistor with a capacitor to ground is low-pass. The same 3.3 kΩ and 47 nF give a 1.026 kHz cutoff either way.

The phase tells them apart on a scope: the high-pass output leads the input by 45° at the cutoff, and a low-pass lags by 45°. For the mirror-image circuit, the Low Pass Filter Calculator uses the same formula.

What is the difference between a passive high-pass filter and an active high-pass filter?

A passive filter uses only R, L and C, needs no power and cannot add gain. An active filter adds an op-amp for gain, buffering and Q control without inductors, at the cost of a supply and an upper band edge set by GBW.

Loading is the main practical gap. A passive 10 kΩ and 15.92 nF filter cuts off at 1 kHz alone, but a 10 kΩ load in parallel with the resistor halves R and moves the cutoff to 2.0 kHz. An active stage's buffered output avoids that shift.

What components do I need for a 1 kHz high-pass filter?

One capacitor and one resistor whose product RC is 159.2 µs; any high pass filter calculator pair with that product works. Common pairs are 1 kΩ with 159.2 nF, 10 kΩ with 15.92 nF and 100 kΩ with 1.592 nF.

RExact CE12 below, cutoffE12 above, cutoff
1 kΩ159.2 nF150 nF, 1.061 kHz180 nF, 884.2 Hz
10 kΩ15.92 nF15 nF, 1.061 kHz18 nF, 884.2 Hz
100 kΩ1.592 nF1.5 nF, 1.061 kHz1.8 nF, 884.2 Hz

To build it, run the capacitor from input to output and the resistor from output to ground. Keep R at least ten times the source impedance and under a tenth of the load, so neither shifts the cutoff by more than about 10%.

Why is the cutoff frequency of a filter called the -3dB point?

Every high pass filter calculator cutoff is quoted at the level where the output voltage is 1 ÷ √2, or 70.7%, of the input. In decibels that is 20 × log(0.7071) = -3.01 dB, and since power goes with voltage squared, the power is exactly half.

At that frequency the capacitor's reactance equals the resistance, so the two voltages are equal in size and 90° apart. A 5 V input gives 3.536 V out with a 45° phase lead.