Low Pass Filter Calculator for RC, RL, LC, op-amp and Sallen-Key filters, giving the cutoff, E12 parts for a target, gain and phase at a test tone, Q, rise time and stacked stages.
Enter the resistor and capacitor. A first-order RC low-pass filter cuts off at fc = 1 ÷ (2πRC).
Test Signal & Stages
Bode Plot of the Filter
Gain and Phase Across Frequencies
| Point | Frequency | Gain | Output | Phase |
|---|---|---|---|---|
| 0.1 × fc | 102.6 Hz | -0.0432 dB | 4.975 V | -5.711° |
| 0.5 × fc | 513.1 Hz | -0.969 dB | 4.472 V | -26.57° |
| fc | 1.026 kHz | -3.01 dB | 3.536 V | -45° |
| 2 × fc | 2.052 kHz | -6.99 dB | 2.236 V | -63.43° |
| Test signal | 5 kHz | -13.9 dB | 1.005 V | -78.4° |
| 10 × fc | 10.26 kHz | -20 dB | 497.5 mV | -84.29° |
| 100 × fc | 102.6 kHz | -40 dB | 50 mV | -89.43° |
Step-by-Step Math
Low Pass Filter Calculator Cutoffs for RC and RL Pairs
A 3.3 kΩ resistor with a 47 nF capacitor cuts off at 1.026 kHz. In a first-order RC low-pass filter the resistor sits in series and the capacitor goes to ground, and the cutoff is where the output has fallen 3 dB, to 70.7% of the input.
fc is the cutoff frequency in hertz, R is the series resistance in ohms and C is the capacitance to ground in farads. The product RC is the time constant τ, so 3.3 kΩ × 47 nF gives τ = 155.1 µs in any low pass filter calculator check.
| Resistor | Capacitor | Time constant | Cutoff |
|---|---|---|---|
| 100 kΩ | 1 µF | 100 ms | 1.592 Hz |
| 10 kΩ | 100 nF | 1 ms | 159.2 Hz |
| 3.3 kΩ | 47 nF | 155.1 µs | 1.026 kHz |
| 10 kΩ | 15 nF | 150 µs | 1.061 kHz |
| 1 kΩ | 100 nF | 100 µs | 1.592 kHz |
| 1 kΩ | 10 nF | 10 µs | 15.92 kHz |
| 4.7 kΩ | 1 nF | 4.7 µs | 33.86 kHz |
Equal time constants give equal cutoffs, so 10 kΩ with 100 nF and 1 kΩ with 1 µF both land at 159.2 Hz. A low pass filter calculator RC result depends only on the product, which leaves the resistor free to suit the source and load.
The RL version swaps the capacitor for a series inductor and takes the output across the resistor. The cutoff then rises with resistance instead of falling, the opposite of the RC case in a low pass filter calculator comparison.
R is the resistance across the output in ohms and L is the series inductance in henries. A 1 kΩ load with 100 mH gives 1.592 kHz, and an 8 Ω speaker behind a 1 mH coil gives 1.273 kHz.
| Resistance across output | Series inductor | Cutoff |
|---|---|---|
| 8 Ω | 1 mH | 1.273 kHz |
| 1 kΩ | 100 mH | 1.592 kHz |
| 100 Ω | 1 mH | 15.92 kHz |
| 1 kΩ | 10 mH | 15.92 kHz |
| 50 Ω | 10 µH | 795.8 kHz |
The same formula works in a spreadsheet as =1/(2*PI()*R*C) for RC or =R/(2*PI()*L) for RL, with values in ohms, farads and henries. In Python it is 1/(2*math.pi*R*C), so a low pass filter calculator in Excel or code needs no more than one line.
Gain, Phase and Output Above the Cutoff
A first-order low-pass filter loses 20 dB per decade above its cutoff. The 1.026 kHz RC filter passes a 5 V signal at 102.6 Hz almost untouched, but at 10.26 kHz only 497.5 mV gets through.
|H| is the output-to-input voltage ratio, f is the signal frequency, fc is the cutoff and φ is the phase lag. The gain in dB is 20 × log10|H|, which is the transfer function of a low pass filter in magnitude form.
| Point | Frequency | Gain | Output from 5 V | Phase |
|---|---|---|---|---|
| 0.1 × fc | 102.6 Hz | -0.0432 dB | 4.975 V | -5.711° |
| 0.5 × fc | 513.1 Hz | -0.969 dB | 4.472 V | -26.57° |
| fc | 1.026 kHz | -3.01 dB | 3.536 V | -45° |
| 2 × fc | 2.052 kHz | -6.99 dB | 2.236 V | -63.43° |
| 5 × fc | 5.131 kHz | -14.1 dB | 980.6 mV | -78.69° |
| 10 × fc | 10.26 kHz | -20 dB | 497.5 mV | -84.29° |
| 100 × fc | 102.6 kHz | -40 dB | 50 mV | -89.43° |
The -20 dB per decade slope per pole is the figure in Analog Devices' Basic Linear Design filter chapter, where each pole adds -6 dB per octave. Doubling the frequency above the knee therefore costs close to 6 dB.
The cutoff is not where filtering starts. This filter is already -0.969 dB at half the cutoff and -1 dB at 522.2 Hz, so a signal that must stay flat within 0.1 dB has to sit below 156.6 Hz.
A low pass filter gain calculator figure at the test frequency is the useful one. A 5 kHz tone through the 1.026 kHz filter comes out at 1.005 V from 5 V, which is -13.9 dB with 78.4° of phase lag.
Picking Standard Parts for a Target Cutoff
A 1 kHz cutoff with a 10 kΩ resistor needs 15.92 nF, which is not a stock value. The nearest E12 capacitors give 1.061 kHz with 15 nF or 884.2 Hz with 18 nF, so the low pass filter calculator choice is between 6% high and 12% low.
C is the capacitor needed for a chosen resistor R, or R is the resistor needed for a chosen capacitor C, at the target cutoff fc. The same 1 kHz target from a 100 nF capacitor needs 1.592 kΩ.
| Target | Fixed part | Exact value | E12 below and cutoff | E12 above and cutoff |
|---|---|---|---|---|
| 10 Hz | 10 kΩ | 1.592 µF | 1.5 µF, 10.61 Hz | 1.8 µF, 8.842 Hz |
| 100 Hz | 10 kΩ | 159.2 nF | 150 nF, 106.1 Hz | 180 nF, 88.42 Hz |
| 1 kHz | 3.3 kΩ | 48.23 nF | 47 nF, 1.026 kHz | 56 nF, 861.2 Hz |
| 1 kHz | 100 nF | 1.592 kΩ | 1.5 kΩ, 1.061 kHz | 1.8 kΩ, 884.2 Hz |
| 3.4 kHz | 4.7 kΩ | 9.96 nF | 8.2 nF, 4.13 kHz | 10 nF, 3.386 kHz |
| 20 kHz | 1 kΩ | 7.958 nF | 6.8 nF, 23.41 kHz | 8.2 nF, 19.41 kHz |
Some pairs land almost exactly on a low pass filter calculator target. The 3.3 kΩ and 47 nF pair misses 1 kHz by 2.6%, and 4.7 kΩ with 10 nF misses 3.4 kHz, the top of the telephone voice band, by less than 0.5%.
Part tolerance matters as much as the E12 step. A ±10% capacitor alone moves the cutoff by about ±10%, so a low pass filter design calculator answer within 2% of target is already inside the spread of real parts.
Second-Order LC and Sallen-Key Responses
A second-order filter falls at 40 dB per decade, twice the first-order rate, and its corner shape depends on Q. A 10 mH inductor and 1 µF capacitor resonate at 1.592 kHz, and the load resistance decides whether the response peaks or sags there.
f0 is the natural frequency, L and C are the series inductor and shunt capacitor, and R is the load across the capacitor. This simple form assumes a zero-ohm source. Q = 0.707 gives the flattest passband, the Butterworth response.
| LC filter, 10 mH and 1 µF | Q | -3 dB point | Peak gain | At 10 × fc | Step overshoot |
|---|---|---|---|---|---|
| 50 Ω load | 0.5 | 1.024 kHz | 0 dB | -32.6 dB | 0% |
| 70.71 Ω load | 0.7071 | 1.592 kHz | 0 dB | -40 dB | 4.32% |
| 100 Ω load | 1 | 2.024 kHz | +1.25 dB | -44.2 dB | 16.3% |
| 1 kΩ load | 10 | 2.469 kHz | +20 dB | -47.6 dB | 85.4% |
The light-load row is the trap in an LC low pass filter calculator answer. With 1 kΩ across a 100 Ω characteristic impedance, Q reaches 10 and the filter amplifies its own corner by 20 dB instead of cutting it.
The same effect turns up in a Class D amplifier's output filter, a common audio low pass filter calculator case.
A 22 µH and 10 µF pair resonates at 10.73 kHz, and into an 8 Ω speaker its Q is 5.394, a +14.7 dB peak unless the load or a damping network holds it down.
Series resistance from the source or the coil's DCR tames that peak in an LC low pass filter calculator result. Adding 0.5 Ω cuts it to +6.19 dB, and 2 Ω brings Q down to 0.7289 with the corner moved up to 12 kHz.
A matched source and load change the low pass filter calculator picture again. The 10 mH and 1 µF pair fed from 100 Ω into 100 Ω has Q = 0.7071 and a -3 dB point at 2.251 kHz, but the passband sits 6.02 dB down from the resistive divider.
A unity-gain Sallen-Key stage reaches the same second-order shape with an op-amp and no inductor. TI's SLOA024 application note gives f0 = 1 ÷ (2π√(R1R2C1C2)) and puts the capacitor to ground in the denominator of Q.
R1 and R2 are the two series resistors, Cf is the feedback capacitor to the output and Cg is the capacitor to ground. TI's own labels swap C1 and C2, so checking which capacitor goes to ground avoids a wrong Q.
| R1 = R2 | C to output | C to ground | f0 | Q | -3 dB point | Overshoot |
|---|---|---|---|---|---|---|
| 10 kΩ | 10 nF | 10 nF | 1.592 kHz | 0.5 | 1.024 kHz | 0% |
| 10 kΩ | 20 nF | 10 nF | 1.125 kHz | 0.7071 | 1.125 kHz | 4.32% |
| 10 kΩ | 22 nF | 10 nF | 1.073 kHz | 0.7416 | 1.123 kHz | 5.68% |
| 10 kΩ | 47 nF | 10 nF | 734.1 Hz | 1.084 | 965 Hz | 19.5% |
Equal parts give Q = 0.5, the value TI states for equal components at unity gain, so the response is soft and the -3 dB point drops to 1.024 kHz. A 2:1 capacitor ratio is what brings a 2nd order low pass filter to Butterworth.
Gain is the other route. TI gives Q = 1 ÷ (3 - K) for equal parts, so a gain of 1.586 makes the 10 kΩ and 10 nF stage Butterworth at 1.592 kHz with +4.01 dB of passband gain, and K = 2 gives Q = 1.
Equal-part stages oscillate at K = 3, where Q runs to infinity and no low pass filter calculator corner exists. At K = 2.5 the same parts already reach Q = 2, so gain settings near the limit turn the filter into a resonator.
Op-Amp Low-Pass Stages With Gain
An inverting op-amp low-pass with Rf = 10 kΩ, Ri = 1 kΩ and 15.9 nF across Rf has +20 dB of passband gain and a 1.001 kHz cutoff. The capacitor across the feedback resistor sets the corner, while the resistor ratio sets the gain.
Rf is the feedback resistor, C is the capacitor across it, Ri is the input resistor and G is the passband voltage gain. The minus sign means the output is inverted, a 180° shift on top of the phase lag in any low pass filter calculator table.
The non-inverting version puts an RC filter in front of the op-amp and sets the gain with two more resistors, G = 1 + Rf ÷ Rg. With 1 kΩ and 100 nF in front and Rf = 10 kΩ over Rg = 1 kΩ, it gives +20.8 dB of gain and a 1.592 kHz cutoff.
| Active filter | Cutoff | Passband gain | Gain at cutoff |
|---|---|---|---|
| Inverting, Ri 1 kΩ, Rf 10 kΩ, C 15.9 nF | 1.001 kHz | +20 dB (-10 V/V) | +17 dB |
| Non-inverting, 1 kΩ and 100 nF, Rf 10 kΩ, Rg 1 kΩ | 1.592 kHz | +20.8 dB (11 V/V) | +17.8 dB |
The op-amp's own bandwidth adds a second pole at GBW ÷ noise gain, which an active low pass filter calculator answer has to include.
For the inverting stage, with a noise gain of 11, a 1 MHz part leaves the 1.001 kHz corner unchanged, a 100 kHz part pulls it to 989.2 Hz and a 20 kHz part to 816.1 Hz.
The Op Amp Gain Calculator and the Non-Inverting Op-Amp Resistor Calculator cover the gain side of these stages and the resistor ratios behind it.
The active stage also isolates the filter from its load, so the low pass filter calculator corner holds. A passive RC filter feeding a 10 kΩ load is no longer the filter on paper, while the op-amp output drives the load without moving the corner.
Stacking Stages for 2nd, 3rd and 4th Order
Four identical buffered RC stages do not cut off at their own corner. Each stage adds -3 dB there, so for a 1 kHz overall cutoff every stage must sit at 2.299 kHz, and the chain falls at 80 dB per decade beyond it.
fc is the overall -3 dB point, f0 is the cutoff of each identical stage and n is the number of stages. The low pass filter calculator factor is 0.6436 for two stages, 0.5098 for three and 0.435 for four.
| Stages for 1 kHz overall | Each stage at | C per stage with 10 kΩ | At 2 kHz | At 10 kHz | -40 dB reached at |
|---|---|---|---|---|---|
| 1, first order | 1 kHz | 15.92 nF | -6.99 dB | -20 dB | 99.99 kHz |
| 2, second order | 1.554 kHz | 10.24 nF | -8.49 dB | -32.6 dB | 15.46 kHz |
| 3, third order | 1.961 kHz | 8.114 nF | -9.29 dB | -42.9 dB | 8.89 kHz |
| 4, fourth order | 2.299 kHz | 6.923 nF | -9.79 dB | -52 dB | 6.897 kHz |
Each added stage buys less. The 4th order low pass filter reaches -40 dB at 6.897 kHz against 99.99 kHz for one stage, but the gain from three to four stages is small next to the jump from one to two.
Identical stages give a soft knee, not a Butterworth one. Two equal stages have Q = 0.5, the same as the equal-part Sallen-Key, so a 3rd order low pass filter calculator answer built this way is gentler than a Butterworth design of the same order.
The stages must be buffered for the low pass filter calculator figures to hold. Two passive RC sections joined directly load each other, pulling the overall cutoff below the figures in the table.
Step Response, Rise Time and Settling
The 3.3 kΩ and 47 nF filter takes 340.8 µs to rise from 10% to 90% after a step, and 714.1 µs to settle within 1%. A first-order rise time is 2.197 time constants, here 2.197 × 155.1 µs from the low pass filter calculator τ.
Bandwidth and rise time trade directly: the product of the two is a constant for a given filter type, which Analog Devices notes in its filter chapter. Halving the low pass filter calculator cutoff doubles the rise time.
Second-order filters trade speed for overshoot. The Butterworth Sallen-Key with a 20 nF and 10 nF pair rises in 303.8 µs and overshoots 4.32%, while the Q = 1.084 version overshoots 19.5% and takes 1.801 ms to settle within 2%.
Identical buffered stages never overshoot, whatever the low pass filter calculator order. The four-stage 1 kHz chain rises in 341.7 µs and settles in 695.3 µs, almost the same as a single 1 kHz stage, even though it rolls off four times faster.
Filter Design Answers by Topology
Each question below gets its own worked figures, from the first RC calculation to choosing between RC, RL, LC and active designs.
What is a low pass filter calculator?
It is a conversion from component values to cutoff frequency, or from a target cutoff back to the part needed. Gain, phase, output level and step response at chosen frequencies complete a full low pass filter calculator answer.
For RC filters the core is fc = 1 ÷ (2πRC), so 3.3 kΩ and 47 nF give 1.026 kHz. Second-order and active designs add Q and gain to the low pass filter calculator output, which decide the shape of the corner and the passband level.
What is a low pass filter?
A low-pass filter passes signals below its cutoff and attenuates those above it. A first-order filter is down 3 dB at the cutoff, 20 dB at ten times it and 40 dB at a hundred times.
Common uses include removing hiss from audio, smoothing PWM into DC, cleaning sensor signals and stopping aliasing before an ADC. Power supplies use LC low-pass filters to remove switching ripple.
How to calculate RC low pass filter?
Multiply R by C to get the time constant, then take 1 ÷ (2π × τ). For 10 kΩ and 100 nF, τ = 1 ms and fc = 159.2 Hz; for 1 kΩ and 10 nF, τ = 10 µs and fc = 15.92 kHz.
Convert units first: kΩ × 1,000 for ohms and nF ÷ 1,000,000,000 for farads. A missed prefix moves the low pass filter calculator RC answer by 1,000 times.
How to calculate RL low pass filter?
Divide the resistance by 2π times the inductance: fc = R ÷ (2πL). A 1 kΩ resistor after a 100 mH inductor gives 1.592 kHz, and 100 Ω after 1 mH gives 15.92 kHz.
The resistance is whatever sits across the output, often the load itself. An 8 Ω speaker behind an ideal 1 mH coil cuts off at 1.273 kHz. A real coil with 0.5 Ω of DCR moves it to 1.353 kHz and drops the level by 0.527 dB.
How do I build a low-pass filter?
For a first-order RC filter, put the resistor in series with the signal and the capacitor from the output node to ground. Choose R to suit the source and load, then choose C for the target cutoff.
For the low pass filter calculator corner to hold, keep the load at least ten times the filter resistance, or buffer the output with an op-amp. A 1 kΩ filter feeding a 10 kΩ input stays close to its calculated corner.
What components do I need for a 1 kHz low-pass filter?
A 10 kΩ resistor with 15.92 nF gives exactly 1 kHz in a low pass filter calculator check; with stock parts, 10 kΩ and 15 nF give 1.061 kHz. The pair 3.3 kΩ and 47 nF gives 1.026 kHz, and 1.5 kΩ with 100 nF gives 1.061 kHz.
For a steeper 1 kHz filter, a unity-gain Sallen-Key with two 10 kΩ resistors, 20 nF to the output and 10 nF to ground gives a Butterworth corner at 1.125 kHz.
What is the difference between a first-order and a second-order low-pass filter?
A first-order filter falls 20 dB per decade; a second-order filter falls 40 dB per decade. At ten times the cutoff, a first-order filter is -20 dB and a Butterworth second-order is -40 dB.
Each extra order adds another 20 dB per decade, so a fourth-order filter falls 80 dB per decade. Higher order also adds phase lag, up to 90° per order, and can add overshoot if Q is above 0.707.
How do you use an RC low-pass filter to smooth a PWM signal into DC voltage?
Set the cutoff far below the PWM frequency. A 10 Hz filter on a 1 kHz PWM signal attenuates the switching fundamental by 40 dB, leaving 1% of it as ripple on the DC level.
The cost is response time: that 10 Hz filter takes about 73 ms to settle within 1%. Two buffered stages for the same 10 Hz cutoff push the ripple down to -72.3 dB. A 555 Timer Astable Oscillator Circuit is a common PWM source for this.
Does a passive low-pass filter affect the input impedance of a circuit?
A passive filter's input impedance falls with frequency. The 3.3 kΩ and 47 nF filter presents 4.667 kΩ at its cutoff and 3.369 kΩ at 5 kHz, where the source must supply 1.484 mA from 5 V.
The output impedance changes too, from 3.3 kΩ at DC to 2.333 kΩ at the cutoff and 663.4 Ω at 5 kHz, as the capacitor shunts more of the signal.
The low pass filter calculator impedance figures assume a zero-ohm source, and any load connected forms a divider, which is why the load should be much larger than the filter resistor.
Why is a low-pass filter necessary before an Analog-to-Digital Converter (ADC)?
Without it, signals above half the sample rate fold back as false low-frequency tones, called aliasing. A 2 kHz first-order filter in front of a 48 kHz converter only reaches -21.6 dB at the 24 kHz Nyquist frequency.
Four buffered stages for the same 2 kHz cutoff reach -58 dB at 24 kHz, while still losing only 0.803 dB at 1 kHz. Steep anti-alias filters are why higher-order designs exist.
What is the resonance frequency in LC filters?
It is f0 = 1 ÷ (2π√(LC)), so 10 mH and 1 µF resonate at 1.592 kHz. That is the -3 dB point only when Q = 0.707; at Q = 1 the -3 dB point moves up to 2.024 kHz.
At resonance the low pass filter calculator gain equals Q, so a lightly loaded LC filter can boost signals there. With a 1 kΩ load on that 100 Ω pair, the gain at 1.592 kHz is +20 dB.
What is the difference between active and passive filters?
Passive filters use only R, L and C and can only lose signal; active filters add an op-amp for gain and buffering. An inverting active filter with Rf ÷ Ri = 10 gives +20 dB in the passband.
Active filters avoid inductors at low frequency and do not load each other, but they need power and are limited by the op-amp's bandwidth. Passive LC filters handle high power and RF better.
Which filter topology should I use (RC, LC, LR)?
RC suits low-power signal filtering, LC suits power supplies, RF and audio crossovers, and LR suits low-impedance loads like speakers.
An 8 Ω speaker needs only 1 mH for a 1.273 kHz cutoff in a low pass filter calculator RL check, while an RC filter at that impedance would need about 15.6 µF.
For signals that need a sharp edge without inductors, an active Sallen-Key gives 40 dB per decade from two resistors and two capacitors. The Bandpass Filter Calculator covers filters that cut both ends.
How do parasitic elements affect filter performance?
Capacitor ESR and ESL, inductor resistance and winding capacitance all move a real filter away from the ideal. Above a capacitor's self-resonant frequency it acts like an inductor, so stopband attenuation stops improving.
Inductor DC resistance lowers the Q of an LC filter and adds loss in the passband. At RF, a few nanohenries of lead inductance or a picofarad of stray capacitance can shift a low pass filter calculator RF design noticeably.