PCB trace width calculator that sizes a trace from its current, copper weight and allowed rise, or finds the safe current or temperature rise of a trace that is already on a board.
Enter the current, copper weight and allowed rise to get the minimum trace width.
Ambient, Length & Supply Rail
Trace Cross-Section Diagram
Temperature Rise vs Current Chart
PCB Trace Width Table by Current
| Current | 0.5 oz Copper | 1 oz Copper | 2 oz Copper | 3 oz Copper |
|---|---|---|---|---|
| 500 mA | 9.09 mil (0.231 mm) | 4.55 mil (0.115 mm) | 2.27 mil (57.7 µm) | 1.52 mil (38.5 µm) |
| 1.00 A | 23.7 mil (0.601 mm) | 11.8 mil (0.300 mm) | 5.91 mil (0.150 mm) | 3.94 mil (0.100 mm) |
| 2.00 A | 61.5 mil (1.56 mm) | 30.8 mil (0.781 mm) | 15.4 mil (0.391 mm) | 10.3 mil (0.260 mm) |
| 3.00 A | 108 mil (2.73 mm) | 53.8 mil (1.37 mm) | 26.9 mil (0.683 mm) | 17.9 mil (0.456 mm) |
| 5.00 A | 218 mil (5.53 mm) | 109 mil (2.77 mm) | 54.4 mil (1.38 mm) | 36.3 mil (0.922 mm) |
| 10.0 A | 566 mil (14.4 mm) | 283 mil (7.19 mm) | 142 mil (3.60 mm) | 94.4 mil (2.40 mm) |
| 15.0 A | 991 mil (25.2 mm) | 495 mil (12.6 mm) | 248 mil (6.29 mm) | 165 mil (4.20 mm) |
| 20.0 A | 1,470 mil (37.4 mm) | 737 mil (18.7 mm) | 368 mil (9.36 mm) | 246 mil (6.24 mm) |
Step-by-Step Math
PCB Trace Width Calculator Table by Current and Copper Weight
On an outer layer with a 10 °C rise, 1 A needs 11.8 mil (0.30 mm) on 1 oz copper and 10 A needs 283 mil (7.19 mm).
This PCB trace width table comes from the IPC-2221 curve fit. Any PCB trace width calculator built on that standard should land on the same numbers.
| Current | 0.5 oz Copper | 1 oz Copper | 2 oz Copper | 3 oz Copper |
|---|---|---|---|---|
| 0.5 A | 9.09 mil (0.23 mm) | 4.55 mil (0.12 mm) | 2.27 mil (0.06 mm) | 1.52 mil (0.04 mm) |
| 1 A | 23.7 mil (0.60 mm) | 11.8 mil (0.30 mm) | 5.91 mil (0.15 mm) | 3.94 mil (0.10 mm) |
| 2 A | 61.5 mil (1.56 mm) | 30.8 mil (0.78 mm) | 15.4 mil (0.39 mm) | 10.3 mil (0.26 mm) |
| 3 A | 108 mil (2.73 mm) | 53.8 mil (1.37 mm) | 26.9 mil (0.68 mm) | 17.9 mil (0.46 mm) |
| 5 A | 218 mil (5.53 mm) | 109 mil (2.77 mm) | 54.4 mil (1.38 mm) | 36.3 mil (0.92 mm) |
| 10 A | 566 mil (14.4 mm) | 283 mil (7.19 mm) | 142 mil (3.60 mm) | 94.4 mil (2.40 mm) |
| 15 A | 991 mil (25.2 mm) | 495 mil (12.6 mm) | 248 mil (6.29 mm) | 165 mil (4.20 mm) |
| 20 A | 1,474 mil (37.4 mm) | 737 mil (18.7 mm) | 368 mil (9.36 mm) | 246 mil (6.24 mm) |
In PCB trace width calculator math the copper cross-section is fixed first, so across a row the width halves each time the copper doubles. Down a column, width grows faster than current: 2 A needs 2.6 times the width of 1 A, not twice.
Cells wider than 400 mil, such as 15 A on 1 oz, sit outside the data behind the IPC-2221 charts. Read them as estimates and cross-check any trace that wide against the IPC-2152 fit below.
How to Calculate PCB Trace Width?
Work out the copper area the current needs, then divide it by the copper thickness. IPC-2221 gives that area from the current and the allowed temperature rise in one curve-fit equation, the PCB trace width calculator formula most designers know.
A is the cross-section in square mils, I the current in amps and ΔT the rise above ambient in °C. The constant k is 0.048 for outer layers and 0.024 for inner layers; 0.44 and 0.725 are the exponents fitted to the IPC-2221 charts.
W is the trace width in mils and oz is the copper weight in ounces per square foot. The factor 1.378 turns ounces into mils of copper thickness.
For 3 A at a 10 °C rise on 1 oz outer copper, 100.44 is 2.754, so k × ΔT0.44 is 0.1322. Then 3 ÷ 0.1322 is 22.69, and 22.69 raised to 1/0.725 gives 74.16 mil².
Dividing 74.16 mil² by 1.378 mil gives a 53.8 mil trace, or 1.37 mm. Round any PCB trace width calculator result up to your CAD grid; a wider trace only runs cooler and drops less voltage.
To build a PCB trace width calculator in Excel, put the current in B1, the copper ounces in B2 and the rise in B3. Then type =POWER(B1/(0.048*POWER(B3,0.44)),1/0.725)/(1.378*B2) and swap 0.048 for 0.024 on an inner layer.
A PCB trace width calculator online that cites IPC-2221 runs this same pair of equations, so its results should match the spreadsheet to the decimal. If they differ, check whether the other source quietly uses a 20 °C rise or 0.5 oz copper.
Internal Layers and the IPC-2152 Correction
Under IPC-2221 PCB trace width calculator math, an inner trace needs 2.6 times the width of an outer one at the same current and rise. For 3 A on 1 oz copper at 10 °C, that is 140 mil (3.56 mm) inside against 53.8 mil (1.37 mm) outside.
That penalty comes from halving k. In Trace Currents and Temperatures Revisited, Douglas Brooks and Johannes Adam note that the old inner charts were the outer charts derated by two, an assumption they call "quite incorrect".
IPC-2152, published in 2009, re-tested traces and found inner traces cool almost as well as outer ones, or better. Brooks and Adam fitted its outer-layer data with a single equation, shown in their PCD&F thermal management article.
Here ΔT is the rise in °C, I the current in amps, W the width in mils and t the copper thickness in mils. They checked it against 2 oz and 3 oz test data; IPC-2152 has no 1 oz outer curve, so 1 oz results come from the equation itself.
| Width (1 oz, 10 °C Rise) | IPC-2221 Outer | IPC-2221 Inner | IPC-2152 Fit | IPC-2152 vs IPC-2221 Outer |
|---|---|---|---|---|
| 5 mil (0.13 mm) | 0.54 A | 0.27 A | 0.64 A | 19% more |
| 10 mil (0.25 mm) | 0.89 A | 0.44 A | 0.95 A | 7% more |
| 20 mil (0.51 mm) | 1.46 A | 0.73 A | 1.42 A | 3% less |
| 50 mil (1.27 mm) | 2.84 A | 1.42 A | 2.40 A | 16% less |
| 100 mil (2.54 mm) | 4.70 A | 2.35 A | 3.57 A | 24% less |
| 200 mil (5.08 mm) | 7.77 A | 3.89 A | 5.32 A | 31% less |
| 400 mil (10.2 mm) | 12.8 A | 6.42 A | 7.93 A | 38% less |
The two methods cross near 16 mil (0.41 mm) at a 10 °C rise. Narrower traces get slightly more current under IPC-2152, while wide outer power traces get much less.
At 100 mil the gap is 24%, in line with Brooks and Adam's finding that IPC-2152 outer currents run about 25% below the older IPC-2221 charts.
For PCB trace width calculator results, the choice of standard splits by layer. An inner 3 A trace on 1 oz needs 73.8 mil under IPC-2152 instead of 140 mil, which is 47% narrower.
On a wide outer power trace the gap runs the other way, and the older IPC-2221 chart becomes the less safe of the two methods.
Current Capacity of 0.2 mm, 0.4 mm, 1 mm and 10 mil Traces
On 1 oz outer copper at a 10 °C rise, a 0.2 mm trace carries about 0.75 A, a 0.4 mm trace about 1.2 A and a 1 mm trace about 2.4 A. Under IPC-2221, the same widths on an inner layer carry exactly half.
Each row is a PCB trace width calculator problem run backward, with the width known and the current found. That is the case for a board already routed or a fixed connector pad.
| Trace Width | 1 oz Outer, 10 °C | 1 oz Outer, 20 °C | 1 oz Inner, 10 °C | 1 oz IPC-2152, 10 °C | 2 oz Outer, 10 °C |
|---|---|---|---|---|---|
| 0.1 mm (3.94 mil) | 0.45 A | 0.61 A | 0.23 A | 0.56 A | 0.75 A |
| 0.2 mm (7.87 mil) | 0.75 A | 1.01 A | 0.37 A | 0.83 A | 1.23 A |
| 10 mil (0.254 mm) | 0.89 A | 1.20 A | 0.44 A | 0.95 A | 1.46 A |
| 0.4 mm (15.7 mil) | 1.23 A | 1.67 A | 0.62 A | 1.24 A | 2.03 A |
| 0.5 mm (19.7 mil) | 1.45 A | 1.96 A | 0.72 A | 1.40 A | 2.39 A |
| 1 mm (39.4 mil) | 2.39 A | 3.24 A | 1.20 A | 2.09 A | 3.95 A |
| 2 mm (78.7 mil) | 3.95 A | 5.36 A | 1.98 A | 3.12 A | 6.53 A |
| 100 mil (2.54 mm) | 4.70 A | 6.38 A | 2.35 A | 3.57 A | 7.77 A |
In any PCB trace width calculator, a 20 °C rise instead of 10 °C lifts capacity about 36%, since current follows rise to the 0.44 power. Doubling to 2 oz adds about 65%, as current follows area to the 0.725 power.
Width does not scale linearly either. A 1 mm trace is 2.5 times as wide as a 0.4 mm trace but carries only 1.94 times the current, which is why a straight amps-per-mm rule fails in any PCB trace width vs current estimate.
Copper Weight in mil and µm, and the Width It Saves
PCB trace width calculator math takes one-ounce copper as 1.378 mil (35 µm) thick and 0.5 oz as 0.689 mil (17.5 µm). Each step up in copper weight cuts the width a given current needs by the same ratio as the thickness grows.
| Copper Weight | Thickness (mil) | Thickness (µm) | Width for 1 A | Width for 5 A | Width for 10 A |
|---|---|---|---|---|---|
| 0.5 oz | 0.689 | 17.5 | 23.7 mil | 218 mil | 566 mil |
| 1 oz | 1.378 | 35.0 | 11.8 mil | 109 mil | 283 mil |
| 2 oz | 2.756 | 70.0 | 5.91 mil | 54.4 mil | 142 mil |
| 3 oz | 4.134 | 105 | 3.94 mil | 36.3 mil | 94.4 mil |
These PCB trace width calculator widths assume an outer layer at a 10 °C rise. The 35 µm figure is a rounded convention: one ounce of copper spread over a square foot at 8.96 g/cm³ comes to 34.1 µm, about 2% less current-carrying area than nominal.
Heavy copper narrows a PCB trace width calculator result for power but does little for fine signal lines. On 2 oz, a 10 mil outer trace carries 1.46 A at a 10 °C rise.
Thicker foil etches with more undercut, though, so check your fabricator's minimum line width for 2 oz before routing a trace that narrow.
Sizing a 20 A Trace on 1 oz Copper
The IPC-2221 PCB trace width calculator answer for 20 A on 1 oz outer copper at a 10 °C rise is 737 mil (18.7 mm). That is well past the 400 mil edge of the chart data, so the realistic choices are a larger rise, heavier copper or a copper pour.
| Option for 20 A | Width (mil) | Width (mm) |
|---|---|---|
| 1 oz outer, 10 °C rise | 737 | 18.7 |
| 1 oz outer, 20 °C rise | 484 | 12.3 |
| 1 oz outer, 30 °C rise | 378 | 9.61 |
| 2 oz outer, 10 °C rise | 368 | 9.36 |
| 2 oz outer, 20 °C rise | 242 | 6.14 |
| 3 oz outer, 20 °C rise | 161 | 4.10 |
| 1 oz inner, 10 °C rise (IPC-2221) | 1,917 | 48.7 |
| 1 oz, 10 °C rise (IPC-2152 fit) | 1,999 | 50.8 |
| 1 oz, 20 °C rise (IPC-2152 fit) | 1,094 | 27.8 |
| 2 oz, 20 °C rise (IPC-2152 fit) | 599 | 15.2 |
The IPC-2152 fit asks for far more on a trace this wide, close to 2 in (50.8 mm) on 1 oz at 10 °C. Even 2 oz at a 20 °C rise needs 599 mil (15.2 mm), so at 20 A a copper pour or 3 oz copper usually beats one routed trace.
Splitting the load across both outer layers halves the current in each PCB trace width calculator input. Two 10 A traces on 1 oz at a 20 °C rise need 186 mil (4.72 mm) each, stitched together with enough vias along the run to share the current.
Voltage Drop Over Long Power Runs
A trace sized only for heat in PCB trace width calculator math can still lose too much voltage. A 1 A trace at 11.8 mil on 1 oz drops 265 mV over 6 in (152 mm), which is 8% of a 3.3 V rail.
ρ is 1.7241 × 10-6 Ω·cm for annealed copper at 20 °C, 0.00393 per °C is its temperature coefficient, T is the trace temperature in °C, L the length in cm and A the cross-section in cm².
| Current | Width (1 oz Outer, 10 °C) | Resistance per Inch at 35 °C | Drop over 6 in | Share of 3.3 V | Share of 12 V |
|---|---|---|---|---|---|
| 1 A | 11.8 mil | 44.1 mΩ | 265 mV | 8.02% | 2.21% |
| 3 A | 53.8 mil | 9.69 mΩ | 174 mV | 5.29% | 1.45% |
| 5 A | 109 mil | 4.79 mΩ | 144 mV | 4.36% | 1.20% |
| 10 A | 283 mil | 1.84 mΩ | 111 mV | 3.35% | 0.92% |
The lowest currents lose the largest share, because a thin trace can stay cool while its resistance stays high. For a rail feeding a load more than a few inches away, size for drop and treat the PCB trace width calculator heat figure as the floor.
Leave margin on a tight drop budget. Brooks and Adam cite measured trace resistivity from 1.7 to 2.4 µΩ·cm, a 40% spread, so a real trace can drop more than expected.
The PCB Trace Resistance Calculator checks resistance alone for any width and length, which helps when a sense line or a long return path sets the budget.
Planes, Short Runs and Airflow Change the Real Rise
Board surroundings can move the real rise away from a PCB trace width calculator estimate by a factor of three.
In Brooks and Adam's simulations, a 6 in, 200 mil, 1 oz trace at 15 A rose 94.7 °C on a bare board but only 33.7 °C with a plane 10 mil below it.
| Case: 200 mil, 1 oz, 15 A | Temperature Rise |
|---|---|
| IPC-2221 outer estimate | 44.6 °C |
| IPC-2152 fit estimate | 79.4 °C |
| Simulated, 6 in, no plane | 94.7 °C |
| Simulated, 1 oz plane on bottom side | 47.9 °C |
| Simulated, plane 10 mil below | 33.7 °C |
| Simulated, 2 in long | 81.5 °C |
| Simulated, 1 in long | 64.6 °C |
The IPC-2221 estimate reads less than half the bare-board result here, so a wide outer trace with no copper nearby is the case where the old chart misleads most. A solid plane under the trace pulls it below even the IPC-2221 figure.
Short traces run cooler because their pads pull heat out of both ends. Frequency works the other way: Brooks and Adam show a 100 mil, 2 oz outer trace at 10 A rising just under 40 °C at DC but almost 114 °C at 30 MHz from skin effect.
Heating is slow, too. Their test trace took about 3.5 minutes to reach 90% of its final temperature, so a load that peaks for a few seconds stays well below the steady DC rise used in PCB trace width calculator current tables.
Spacing, Impedance and Other Trace Width Answers
Signal traces rarely carry enough current to warm up, so spacing and impedance rules set their width rather than a PCB trace width calculator. Power traces are the opposite, where heat and voltage drop decide the minimum.
What is the standard trace width for PCBs?
No single standard width exists; IPC-2221 sizes each trace from its current and allowed rise. On 1 oz outer copper at a 10 °C rise, 6, 8, 10 and 12 mil traces carry about 0.61, 0.75, 0.89 and 1.01 A, enough for nearly any logic signal.
Above that, width follows the load. Signal nets usually run at the fabricator's comfortable minimum or at the width a 50 Ω target needs, and power nets at the PCB trace width calculator result for their current.
What is the recommended trace width for a 1 amp current?
Route 1 A at 11.8 mil (0.30 mm) or wider on 1 oz outer copper for a 10 °C rise. A 20 °C rise allows 7.8 mil (0.20 mm), and 2 oz copper brings the 10 °C width down to 5.9 mil (0.15 mm).
On an inner layer, IPC-2221 asks for 30.8 mil (0.78 mm), while the IPC-2152 fit needs only 10.9 mil (0.28 mm) for the same PCB trace width calculator inputs.
On a long run feeding a 3.3 V or lower rail, widen it again so voltage drop stays inside the regulator's tolerance.
How much current can a PCB trace carry?
The IPC-2221 chart data stops at 35 A, which is what a 400 mil, 1 oz outer trace reaches at a 100 °C rise. Run the PCB trace width calculator math in reverse and a 100 mil (2.54 mm) 1 oz outer trace carries 4.7 A at a 10 °C rise and 6.4 A at 20 °C.
The hard ceiling is temperature, not current. Keep ambient plus rise below about 130 °C for standard FR-4. A 5 mil, 1 oz trace at 2 A already rises close to 100 °C in Brooks and Adam's data, so narrow traces reach that limit fast.
What is the 3W rule for PCB traces?
Keep the center-to-center spacing of parallel signal traces at least three times the trace width, which leaves a gap of twice the width. An 8 mil trace then needs 24 mil center to center, or a 16 mil clear gap.
A HyperLynx study in Electronic Science and Technology (2011) found 3W spacing cuts crosstalk by about 70% in general. Altium notes that thinner dielectrics allow tighter spacing for the same crosstalk.
For a numeric check on a real stackup, the Microstrip Crosstalk Calculator and Stripline Crosstalk Calculator give coupling for a given gap and height.
How does trace width affect impedance?
A wider trace has lower impedance, because extra width adds capacitance to the plane below. With the IPC-2141 microstrip equation on FR-4 (εr 4.5, 1 oz) 8 mil above a plane, 6 mil gives about 73 Ω, 13 mil about 50 Ω and 20 mil about 36 Ω.
Height matters as much as width, and a PCB trace width calculator for current ignores the dielectric entirely. The same 50 Ω on a 1.6 mm two-layer board needs about 113 mil (2.87 mm).
The Microstrip Trace Width Calculator solves width for a target impedance, and the Microstrip Impedance Calculator works the other way.