Via Current Calculator

Updated

Via current calculator for plated PCB vias: rate a barrel by hole size and plating, count the vias a current needs, find the smallest hole, or check how hot a via runs at its load.

Via Current Setup

Enter the hole, plating and allowed rise to get the current one via carries.

Via Type
Via Fill
vias
Board Thickness & Ambient62 mil board · 25 °C
1.92 A Max Current per Via
Exact 1.9227 A · 40.1 mil² barrel copper, same as a 29.1 mil 1 oz trace
7.69 A for 4 Parallel Vias
Resistance of 4 Vias277 µΩ
Heat of 4 Vias at Full Load16.4 mW
Parallel vias add up only when placed close together, so the current splits evenly.
1.11 mΩ Via Resistance
At 25.0 °C Ambient1.07 mΩ
Voltage Drop at 1.92 A2.13 mV
Barrel resistance over the board thickness, raised to the hot barrel temperature.
35.0 °C Barrel Temperature
Heat per Via (I²R)4.10 mW
Barrel Thermal Resistance152 °C/W
Ambient plus the rise. Keep it under about 130 °C (266 °F), the Tg of standard FR-4.
1.62 A at 20 µm Class 2
At 35 µm (1 oz)2.51 A
Same 1.92 A if Buried+48.3 °C
Fabs often plate only to the class minimum, so check the current at that plating.
Via Cross-Section Diagramd 12.0 mil · t 25.0 µm · h 62.0 mil
dh = 62.0 milI = 1.92 A · +10.0 °CR = 1.11 mΩ at 35.0 °Cd = 12.0 mil (0.305 mm)t = 25.0 µm (0.984 mil)A = π(d + t)t = 40.1 mil²
Temperature Rise vs Current Chart12.0 mil hole, 25.0 µm
0025.01.25 A50.02.50 A75.03.75 A1005.00 ACurrent per viaRise (°C)1.92 A, +10.0 °C
Through via (k 0.048)Buried via (k 0.024)
Via Current Capacity TableThrough, +10.0 °C
Finished Hole20 µm Plating25 µm Plating35 µm Plating
6.00 mil (0.152 mm)1.02 A1.23 A1.63 A
8.00 mil (0.203 mm)1.23 A1.47 A1.94 A
10.0 mil (0.254 mm)1.43 A1.70 A2.23 A
12.0 mil (0.305 mm)1.62 A1.92 A2.51 A
16.0 mil (0.406 mm)1.97 A2.34 A3.03 A
20.0 mil (0.508 mm)2.30 A2.72 A3.52 A
24.0 mil (0.610 mm)2.61 A3.09 A3.99 A
32.0 mil (0.813 mm)3.20 A3.78 A4.87 A
40.0 mil (1.02 mm)3.75 A4.42 A5.69 A
Step-by-Step Math8 steps
1. Inputs in Formula Unitst = 25 µm ÷ 25.4 = 0.9843 mil
2. Barrel Copper AreaA = π × (d + t) × t = π × (12 + 0.9843) × 0.9843 = 40.15 mil²
3. Max Current per ViaI = k × ΔT0.44 × A0.725 = 0.048 × 100.44 × 40.150.725 = 1.923 A
4. Barrel TemperatureT = Tamb + ΔT = 25 + 10 = 35 °C
5. Via ResistanceR = ρ × [1 + α(T - 20)] × h ÷ A = (1.7241 × 10-6) Ω·cm × [1 + 0.00393 × (35 - 20)] × 0.1575 cm ÷ (2.590 × 10-4) cm² = 1.110 × 10-3 Ω
6. Drop and HeatV = I × R = 1.923 × (1.110 × 10-3) = 2.13 mV; P = I² × R = 1.923² × (1.110 × 10-3) = 4.10 mW
7. Thermal Resistanceθ = h ÷ (kCu × A) = (1.575 × 10-3) m ÷ (401 × (2.590 × 10-8) m²) = 151.6 °C/W
8. Result1.92 A Max Current per Via
Each Via Carries up to 1.92 A
Stay at or below 1.92 A per via for a +10.0 °C rise. IPC-2221 has no via formula, so this applies its outer-conductor chart to the via copper, the method most via calculators use.

Via Current Calculator Math: Barrel Area and IPC-2221

A via carries what its plated barrel can carry, so the copper ring's area goes into the IPC-2221 conductor equation. A 0.3 mm finished hole with 25 µm plating holds 39.6 mil² of copper and carries 1.90 A at a 10 °C rise.

A is the barrel cross-section in square mils, d the finished hole diameter and t the plating thickness, both in mils. It is the ring between the hole and the outer wall at d + 2t, the start of every via current calculator formula.

I is the current one via carries in amps and ΔT the allowed rise in °C. The constant k is 0.048 for a through via and 0.024 for a buried via, the outer-layer and inner-layer values of IPC-2221.

IPC-2221 has no via equation of its own. Applying its conductor chart to the barrel copper is a convention, which is why any PCB via current calculator built this way lands on the same 1.90 A for that 0.3 mm via.

Worked through for a 12 mil (0.305 mm) hole with 25 µm (0.984 mil) plating, π × 12.984 × 0.984 gives 40.15 mil². Then 0.048 × 100.44 × 40.150.725 is 0.048 × 2.754 × 14.54, or 1.92 A.

For a via current calculator in Excel, put the hole in B1 and the plating in B2, both in mils, and the rise in B3. Then type =0.048*POWER(B3,0.44)*POWER(PI()*(B1+B2)*B2,0.725) and swap 0.048 for 0.024 on a buried via.

That 0.3 mm barrel holds as much copper as a 28.7 mil (0.73 mm) trace on 1 oz copper. Comparing it with the PCB Trace Width Calculator result for the trace it joins shows at once whether one via can keep up.

Parallel Vias for 3, 5, 10 and 20 A

For parallel vias, divide the total current by one via's rating and round up, as in any via current calculator count. At a 10 °C rise, 10 A needs 6 vias of 0.3 mm with 25 µm plating, 7 with 20 µm plating, or 4 vias of 0.5 mm with 25 µm plating.

Total Current0.25 mm, 20 µm (1.41 A each)0.3 mm, 20 µm (1.60 A each)0.3 mm, 25 µm (1.90 A each)0.5 mm, 25 µm (2.69 A each)1 A per Via Rule
3 A32223
5 A44325
10 A876410
20 A151311820

The common 0.5 to 1 A per via rule asks for 10 to 20 vias at 10 A, up to three times the via current calculator count. It errs safe, but it fills the space under a wide power trace with drill holes that buy little.

Barrel copper adds linearly in via current calculator math. Four 12 mil vias hold four times the copper and carry 7.69 A at a 10 °C rise, not twice one via as a square-root rule would claim, provided they sit together where the current enters.

Rounding up a via current calculator answer also lowers the real rise. Spreading 10 A over 6 vias of 0.3 mm with 25 µm plating puts 1.67 A on each, so every barrel settles near a 7.4 °C rise instead of the full 10 °C.

Plating Thickness From 12 µm Microvias to 1 oz

IPC-6012 asks for 20 µm of average hole-wall copper on Class 2 boards and 25 µm on Class 3, with thin spots no less than 18 µm and 20 µm, as the JLCPCB summary of IPC-6012 lists them.

Microvias are held to far less. The IPC-6012 requirement table sets a 12 µm average for blind and buried microvias in Class 2, so a microvia barrel starts with under half the copper of a drilled via.

Finished Hole12 µm20 µm25 µm35 µm25 µm at 20 °C Rise
0.15 mm (5.9 mil)0.67 A1.01 A1.21 A1.61 A1.65 A
0.2 mm (7.9 mil)0.82 A1.22 A1.46 A1.92 A1.98 A
0.25 mm (9.8 mil)0.96 A1.41 A1.69 A2.21 A2.29 A
0.3 mm (11.8 mil)1.08 A1.60 A1.90 A2.48 A2.58 A
0.4 mm (15.7 mil)1.33 A1.95 A2.31 A3.00 A3.13 A
0.5 mm (19.7 mil)1.55 A2.28 A2.69 A3.48 A3.65 A
0.6 mm (23.6 mil)1.77 A2.58 A3.06 A3.95 A4.15 A
0.8 mm (31.5 mil)2.17 A3.17 A3.74 A4.81 A5.07 A
1.0 mm (39.4 mil)2.55 A3.71 A4.37 A5.62 A5.93 A

Every cell is a through via at a 10 °C rise unless marked. This via current capacity table also answers the 10 mil case: a 10 mil (0.254 mm) via carries 1.43 A at 20 µm, 1.70 A at 25 µm and 2.23 A at 35 µm.

Plating moves a via current calculator rating less than it moves copper. On a 0.3 mm via, going from 25 µm to 35 µm adds 40% more plating but only 30% more current, while dropping to 20 µm costs 16% of the rating.

Rate the via at the class minimum, not at the plating a fabricator quotes for the surface. Plating builds thinnest in the middle of the hole, and that thin ring is the copper that actually carries current in any via current calculator estimate.

Measured Vias Run Far Cooler Than the Formula

A real via stays close to the temperature of the traces it joins, a fact outside via current calculator math. Douglas Brooks and Johannes Adam measured one 10 mil via, plated to about 1 oz, at 109 °C on a 27 mil trace carrying 6.6 A.

The identical via on a 200 mil trace carrying more current, 8.6 A, measured only 44.5 °C. Heat flowed out of the barrel into the wide, cooler trace, as reported in their PCD&F via temperature study.

The barrel math for that via predicts a 215 °C rise at 8.6 A and rates it at only 2.23 A for a 10 °C rise. Any via current calculator result is therefore a conservative bound, because it treats the barrel as an isolated conductor in still air.

Brooks and Adam conclude that properly sized traces need "much smaller and fewer vias" than designers once assumed. Size the trace first, then keep the via current calculator count as a floor wherever a via sits near a hot part or a narrow neck.

The same logic settles the IPC-2152 via current calculator question. IPC-2152 changes trace ratings, but the via follows the trace, so a trace sized by the newer data already sets the via's operating temperature.

Buried and Blind Vias Under a Halved k

In via current calculator math, IPC-2221 rates a buried via at half the current of a through via of the same size. A 0.3 mm buried via with 25 µm plating is rated 0.95 A at a 10 °C rise, and at the through rating of 1.90 A it would rise 48.3 °C.

The halving comes from the inner-layer chart, which assumes embedded copper cools worse. In their IPC-2152 analysis, Brooks and Adam note that the old inner charts were outer charts derated by two, a practice they call "quite incorrect".

A buried via is also short. Through a 0.2 mm core, a 0.3 mm barrel with 25 µm plating measures 0.143 mΩ against 1.14 mΩ through a 1.6 mm board, so it drops one-eighth the voltage and makes one-eighth the heat.

Blind microvias carry the least, mainly from thin plating. A 0.1 mm microvia with 12 µm plating is rated 0.52 A at a 10 °C rise with the through-via k and 0.26 A with the buried k, so take the lower figure as the safe via current calculator answer.

Board Thickness Changes Resistance, Not the Rating

Board thickness does not change an IPC-style current rating, because barrel length is not in the formula. It raises resistance, voltage drop and heat in direct proportion.

For the barrel length in a via current calculator, use the full board thickness for a through via and only the drilled span for a blind or buried one.

ρ is 1.7241 × 10-6 Ω·cm for annealed copper at 20 °C, T is the barrel temperature in °C, h the barrel length in cm and A the barrel cross-section in cm².

Board ThicknessResistance at 35 °CDrop at 1.90 AHeat at 1.90 ABarrel Thermal Resistance
0.8 mm (31.5 mil)0.572 mΩ1.09 mV2.07 mW78.2 °C/W
1.0 mm (39.4 mil)0.715 mΩ1.36 mV2.59 mW97.7 °C/W
1.6 mm (63.0 mil)1.14 mΩ2.18 mV4.14 mW156 °C/W
2.0 mm (78.7 mil)1.43 mΩ2.72 mV5.18 mW195 °C/W
2.4 mm (94.5 mil)1.72 mΩ3.27 mV6.21 mW235 °C/W
3.2 mm (126 mil)2.29 mΩ4.35 mV8.28 mW313 °C/W

Rows are for one 0.3 mm via with 25 µm plating at its 10 °C rating. Even on a 3.2 mm board the drop is 4.35 mV, so heat, not voltage, sets the via current calculator count unless many layer changes sit in series on one rail.

The trace on either side of the via usually drops far more. The PCB Trace Resistance Calculator gives that part of the path, which belongs in the same drop budget as the current through via calculator figures.

Answers on 1 A Vias, Thermal Vias, Pads and Fill

A via's job decides which number matters. Power vias are sized for current, thermal vias for heat flow, and signal vias for impedance and routing density rather than any via current calculator figure.

What is via current (I)?

Via current is the steady current one plated barrel carries, in amps, written as I in the formula. A standard 0.3 mm via with 25 µm plating is rated 1.90 A for a 10 °C rise on a through via.

When several vias share a path, I in any via current calculator check is the share on each one. A 5 A rail over three such vias puts about 1.67 A through each barrel, inside the single-via rating.

What is the smallest via that can carry 1 A?

With 25 µm plating, a 0.11 mm (4.3 mil) finished hole carries 1 A at a 10 °C rise, so every drilled via of 0.15 mm or larger handles 1 A. With 20 µm plating, the minimum hole for 1 A is 0.15 mm.

Microvias fall short. With 12 µm plating, 1 A needs a 0.27 mm hole, so a 0.1 mm microvia rated 0.52 A needs two in parallel, or a 20 °C rise, which shrinks the needed hole to 0.17 mm.

What temperature rise should I use?

A 10 °C rise is the usual starting point for a via current capacity and temperature rise calculator check. For a 0.3 mm via with 25 µm plating, 20 °C lifts the rating from 1.90 A to 2.58 A and 30 °C to 3.08 A.

Check the total, not just the rise. Ambient plus rise should stay below about 130 °C, the Tg of standard FR-4, so a 30 °C rise inside a 60 °C enclosure leaves the barrel at 90 °C with margin to spare.

Should I use filled or hollow vias for power?

Hollow vias in parallel are the simpler way to add current; copper fill adds capacity per hole. A 0.3 mm via filled solid with copper holds 149 mil², 3.8 times the hollow barrel, worth about 5.0 A at 10 °C by the same formula.

Non-conductive epoxy fill adds no current capacity at all. Rate an epoxy-filled power via in a via current calculator exactly like a hollow one of the same hole and plating.

What is the difference between thermal vias and signal vias?

Thermal vias move heat, so their key figure is thermal resistance rather than current. One hollow 0.3 mm via with 25 µm plating through 1.6 mm conducts heat along its copper at 156 °C/W.

θ is the barrel's thermal resistance in °C/W, h the barrel length in m, kCu the thermal conductivity of copper at 401 W/m·K and A the copper cross-section in m².

Nine hollow vias in parallel bring that to 17.4 °C/W, and nine copper-filled ones to about 4.6 °C/W. Signal vias carry milliamps, so their hole size follows the fab's drill limits and impedance needs.

How do I calculate the via pad diameter?

Add twice the minimum annular ring to the largest finished hole, then the fabricator's registration allowance. IPC-6012 asks for a 50 µm outer annular ring and 25 µm on inner layers for Class 2 and 3, as this IPC-6012 annular ring table shows.

For a 0.3 mm finished hole, the 50 µm ring alone needs a 0.4 mm pad before any allowance. The fabricator's capability sheet gives the allowance that sets the final pad size.