Total dynamic head calculator for surface, well and pool pumps: elevation, pressure head, pipe friction and Crane fitting losses at your flow, plus NPSH, pump power and motor size.
Elevation runs from the source water level to the highest point the water reaches.
Fittings, Valves and Equipment
Suction Lift and NPSH
Pump, Fluid and Pipe Roughness
TDH System Curve
| Share of Flow | Flow Rate | System TDH | Pressure |
|---|---|---|---|
| 50% | 20.00 GPM | 105.4 ft | 45.64 psi |
| 75% | 30.00 GPM | 106.6 ft | 46.17 psi |
| 100% | 40.00 GPM | 108.2 ft | 46.88 psi |
| 125% | 50.00 GPM | 110.3 ft | 47.76 psi |
| 150% | 60.00 GPM | 112.7 ft | 48.80 psi |
Total Dynamic Head by Pipe Size
| Pipe Size | Inside Diameter | Velocity | Friction Head | TDH | Motor |
|---|---|---|---|---|---|
| 1/2 in | 0.622 in | 42.23 ft/s | 1,368 ft | 1,472 ft | 25 HP |
| 3/4 in | 0.824 in | 24.07 ft/s | 348.2 ft | 452.5 ft | 10 HP |
| 1 in | 1.049 in | 14.85 ft/s | 107.6 ft | 211.8 ft | 5 HP |
| 1-1/4 in | 1.380 in | 8.58 ft/s | 28.33 ft | 132.6 ft | 3 HP |
| 1-1/2 in | 1.610 in | 6.30 ft/s | 13.38 ft | 117.6 ft | 2 HP |
| 2 in | 2.067 in | 3.82 ft/s | 3.97 ft | 108.2 ft | 2 HP |
| 2-1/2 in | 2.469 in | 2.68 ft/s | 1.67 ft | 105.9 ft | 2 HP |
| 3 in | 3.068 in | 1.74 ft/s | 0.58 ft | 104.8 ft | 2 HP |
| 4 in | 4.026 in | 1.01 ft/s | 0.15 ft | 104.4 ft | 2 HP |
| 6 in | 6.065 in | 0.44 ft/s | 0.02 ft | 104.3 ft | 2 HP |
| 8 in | 7.981 in | 0.26 ft/s | 0.00554 ft | 104.3 ft | 2 HP |
Step-by-Step TDH Math
Total Dynamic Head Calculator Example, Term by Term
A surface pump moving 40 GPM up 35 ft into a 30 psi system through 150 ft of 2 in pipe needs 108.23 ft of total dynamic head. Pressure and elevation make up 104.26 ft, and the straight pipe adds 3.97 ft in this total dynamic head calculation example.
The total dynamic head formula for a pump sums four terms, each in feet of head at the design flow, so every term adds directly.
Hs is the elevation from the source water level to the highest discharge point, and Hp is the pressure needed at the end in feet of head. hf is pipe friction and hm is the loss through fittings and valves.
Every total dynamic head calculator estimate starts from a real layout. This case uses 150 ft of 2 in Schedule 40 PVC with a 2.067 in bore and Hazen-Williams C 150, with fittings added in the next section.
| Head term | Head | Share of TDH |
|---|---|---|
| Elevation, source level to top | 35.00 ft | 32.3% |
| Pressure head, 30 psi × 2.309 | 69.26 ft | 64.0% |
| Pipe friction, 150 ft at 3.82 ft/s | 3.97 ft | 3.7% |
| Total dynamic head | 108.23 ft (46.9 psi) | 100% |
Pressure head is the largest term in most total dynamic head calculator work on pressure systems. A sprinkler zone or pressure tank at 30 psi costs more head than a 35 ft climb, so get the end pressure right before you worry about pipe roughness.
Drop the 30 psi and the same 40 GPM through the same pipe needs only 38.97 ft, which is the elevation plus friction alone.
WHP is water horsepower, Q is flow in GPM, TDH is in feet and SG is specific gravity, 1.0 for water. The 3,960 constant is foot-pounds per minute in one horsepower divided by the 8.33 lb weight of a gallon of water.
At 40 GPM and 108.23 ft this pump does 1.09 hp of work on the water. At 60% pump efficiency the shaft needs 1.82 brake horsepower, so the next standard NEMA motor size is 2 HP. A pump TDH calculator result in kW follows the IEC motor steps instead.
Fittings and Valves in Pump Head Loss
Four 90° elbows, a 45° elbow, a branch tee, a gate valve, a swing check and a foot valve add 3.13 ft to the example above, almost as much as the 3.97 ft lost in 150 ft of straight pipe. TDH rises to 111.36 ft.
The common "add 10% for fittings" rule would allow just 0.40 ft, so a total dynamic head calculator based on it undercounts this layout nearly 8 times.
Each fitting's loss is K times the velocity head. The K values follow Crane Technical Paper 410, where K equals a fixed L/D ratio times the fully turbulent friction factor fT, which is 0.0190 for a 2 in bore.
| Fitting | Crane L/D | K in 2 in pipe | Equivalent pipe | Head at 40 GPM |
|---|---|---|---|---|
| Foot valve with strainer, poppet disc | 420 | 7.98 | 72.3 ft | 1.81 ft |
| Swing check valve | 100 | 1.90 | 17.2 ft | 0.43 ft |
| Tee, flow through branch | 60 | 1.14 | 10.3 ft | 0.26 ft |
| 90° standard elbow | 30 | 0.57 | 5.2 ft | 0.13 ft |
| Tee, flow straight through | 20 | 0.38 | 3.4 ft | 0.09 ft |
| 45° standard elbow | 16 | 0.30 | 2.8 ft | 0.07 ft |
| Gate valve, fully open | 8 | 0.15 | 1.4 ft | 0.04 ft |
| Ball valve, fully open | 3 | 0.06 | 0.5 ft | 0.01 ft |
The foot valve alone takes 1.81 ft, more than the other six fittings combined. Dropping it for a flooded suction cuts the fittings loss from 3.13 ft to 1.31 ft and the TDH to 109.54 ft.
Crane lists 100 fT for a conventional swing check and 50 fT for a clearway design. Using 100 keeps a total dynamic head calculator estimate on the safe side when the check valve type is not yet known.
Entrance and exit losses stay out of the standard four-term TDH sum. At 3.82 ft/s an exit loss of one velocity head would add 0.23 ft, just 0.2% of the total dynamic head calculator result.
Pipe Size Sets Friction Head and Motor Size
Moving the same 40 GPM through 1-1/2 in Schedule 40 PVC instead of 2 in raises TDH by 15.3 ft and pushes the motor from 2 HP to 3 HP. Friction head falls with the bore to the 4.87 power, so one size step matters far more than pipe length.
Every row below keeps the 35 ft rise, 30 psi end pressure, 150 ft run, the same fittings and 60% pump efficiency. Only the pipe size changes, which is the decision most pump pressure loss calculator checks come down to.
| Sch 40 PVC size | Inside diameter | Velocity | Friction and fittings | TDH | Brake hp | Motor |
|---|---|---|---|---|---|---|
| 1-1/4 in | 1.380 in | 8.58 ft/s | 45.70 ft | 150.0 ft | 2.52 | 3 HP |
| 1-1/2 in | 1.610 in | 6.30 ft/s | 22.40 ft | 126.7 ft | 2.13 | 3 HP |
| 2 in | 2.067 in | 3.82 ft/s | 7.09 ft | 111.4 ft | 1.87 | 2 HP |
| 2-1/2 in | 2.469 in | 2.68 ft/s | 3.14 ft | 107.4 ft | 1.81 | 2 HP |
| 3 in | 3.068 in | 1.74 ft/s | 1.17 ft | 105.4 ft | 1.77 | 2 HP |
In this total dynamic head calculator comparison the 2 in line is the sensible stop. Going to 2-1/2 in saves only 4.0 ft and no motor size.
The 1-1/2 in line also runs at 6.30 ft/s, over the 5 ft/s that the Spears PVC friction loss tables allow for surge control.
Pipe friction uses the head form of Hazen-Williams, which gives the loss in feet of water for every 100 ft of pipe at the design flow.
Q is flow in GPM, d is the inside diameter in inches and C is 150 for PVC, poly, HDPE and copper or 120 for steel. It lands within 0.7% of the psi form in NFPA 13 from 1-1/4 in to 4 in pipe.
The Hazen Williams Equation Calculator runs that loss for a single pipe when you only need the friction term.
To find each bore's speed against its material limit first, the Water Velocity Calculator uses the same pipe tables.
Well Pump TDH and Pressure Tank Settings
A submersible well pump must lift from the pumping water level, not from the pump. For a well with water standing 60 ft down and 20 ft of drawdown, the lift starts at 80 ft, even with the pump hung at 115 ft.
Static head for a well adds the pumping level, the rise from the wellhead to the tank and the tank's cut-out pressure as head. Size the total dynamic head calculator input to the cut-out (upper) setting, because the pump has to reach it to shut off.
The cases below move 10 GPM through 160 ft of 1 in poly pipe with a 1.049 in bore, two elbows, a tee, a gate valve and a check valve, with the tank 12 ft above the wellhead and 50% pump efficiency.
| Tank cut-out pressure | Static head | TDH | Brake hp | Motor |
|---|---|---|---|---|
| 40 psi | 184.4 ft | 194.3 ft | 0.98 | 1 HP |
| 50 psi | 207.4 ft | 217.4 ft | 1.10 | 1-1/2 HP |
| 60 psi | 230.5 ft | 240.5 ft | 1.21 | 1-1/2 HP |
| 70 psi | 253.6 ft | 263.5 ft | 1.33 | 1-1/2 HP |
Each 10 psi step on the pressure switch adds 23.1 ft of head. Raising a 30/50 switch to 40/60 moves the duty point from 217.4 ft to 240.5 ft at 10 GPM, so check that the pump curve still crosses that point before changing the switch.
Friction is only 9.9 ft of the 217.4 ft total at 10 GPM, and the 115 ft of drop pipe inside the well carries 6.3 ft of it.
Halving the flow to 5 GPM lowers TDH only to 210.2 ft, since the static head does not change with flow. A static head calculator alone would put this well at 207.4 ft and miss the friction.
Gauge Readings Turned Into Measured TDH
A running pump reading 24 psi on the discharge and 6 inHg vacuum on the suction is producing 64.8 ft of head at 40 GPM.
Gauges measure what the pump really does, so gauge readings test a worn or clogged pump against its curve without any total dynamic head calculator guesswork about the pipe.
Pd and Ps are the discharge and suction gauge readings in psi, with vacuum as a negative number, and Δz is the height of the discharge gauge above the suction gauge in feet. The last term is the change in velocity head, with g at 32.174 ft/s².
In this case 6 inHg vacuum is -2.95 psi, using 2.036 inHg per psi. The discharge gauge sits 2.5 ft higher, the discharge pipe is 2 in and the suction is 2-1/2 in, so velocity head adds just 0.12 ft.
| Suction reading treated as | Pressure rise | Measured TDH | Error |
|---|---|---|---|
| -2.95 psi vacuum, correct | 26.95 psi | 64.8 ft | 0% |
| Ignored, set to 0 | 24.00 psi | 58.0 ft | -10.5% |
| Read as +2.95 psi | 21.05 psi | 51.2 ft | -21.0% |
Reading the vacuum as pressure makes a healthy pump look 21% short of its curve in any total dynamic head calculator check.
Mark the corrected point, 40 GPM at 64.8 ft, on the curve. A point well below it points to impeller wear, a clog or air in the suction.
Pool Pump and Return Line Head
A pool returns water to the same surface it came from, so elevation is close to zero. A pool pump head calculator result is mostly filter loss plus pipe and fitting friction, and the pipe size swings it more than in any other system.
The cases below move 50 GPM through 100 ft of Schedule 40 PVC with ten 90° elbows, two 45° elbows, two tees, two ball valves and a check valve, at 45% pump efficiency.
The 8 psi filter is an example input. For your own total dynamic head calculator run, use the loss your filter's spec sheet gives at your flow.
| Sch 40 PVC size | Velocity | Pipe and fittings | TDH, no filter | TDH, 8 psi filter | Motor with filter |
|---|---|---|---|---|---|
| 1-1/2 in | 7.88 ft/s | 23.57 ft | 23.6 ft | 42.0 ft | 1-1/2 HP |
| 2 in | 4.78 ft/s | 7.49 ft | 7.5 ft | 26.0 ft | 3/4 HP |
| 2-1/2 in | 3.35 ft/s | 3.33 ft | 3.3 ft | 21.8 ft | 3/4 HP |
The 8 psi filter adds 18.5 ft, more than all the 2 in plumbing. Going from 1-1/2 in to 2 in plumbing halves the pump size, while 2-1/2 in saves 4.2 ft but no motor step.
Filter loss grows with flow squared, the same as pipe loss, so a total dynamic head calculator scales it at every flow.
Flow for a pool comes from its volume and turnover time, so 24,000 gal turned over in 8 hours needs 50 GPM. The Pool Calculator gives the gallons for that step.
An aquarium or sump return pump works the same way. Pushing 10 GPM (600 GPH) up 4.5 ft through 8 ft of 1 in PVC with three elbows, a ball valve and a check valve takes 5.87 ft of head, and 3/4 in pipe raises it to 8.53 ft.
That is why a return pump rated at the rise height alone delivers far less than its box flow. A return pump head loss calculator total, not the 4.5 ft lift, is the point to read on its curve.
Altitude, Temperature and NPSH Available
A surface pump drawing from 8 ft below has 22.3 ft of net positive suction head available at 500 ft altitude with 68°F water. At 7,500 ft with 160°F water the same suction leaves only 4.6 ft, enough to make most pumps cavitate.
The total dynamic head calculator answer can be right while the pump still fails on the suction side, so NPSH needs its own check.
Hatm is air pressure as head, from the US Standard Atmosphere, and Hlift is the height from the water to the pump. hfs is suction-side friction and fittings, and Hvp is the water's vapor pressure as head, from the Antoine equation.
Each row below keeps 8 ft of lift, 15 ft of 2 in suction pipe and a foot valve at 40 GPM, which together lose 2.21 ft. Only the site altitude and the water temperature change.
| Site altitude | Air pressure head | NPSHa at 68°F | NPSHa at 120°F | NPSHa at 160°F |
|---|---|---|---|---|
| Sea level | 33.9 ft | 22.9 ft | 19.8 ft | 12.8 ft |
| 2,500 ft | 31.0 ft | 20.0 ft | 16.9 ft | 9.8 ft |
| 5,000 ft | 28.2 ft | 17.2 ft | 14.1 ft | 7.1 ft |
| 7,500 ft | 25.7 ft | 14.7 ft | 11.6 ft | 4.6 ft |
Vapor pressure head climbs from 0.78 ft at 68°F to 10.92 ft at 160°F. Hot water lowers the suction limit far more than altitude does, so a hot tank needs a flooded suction or a submersible pump whatever the total dynamic head calculator says.
Compare NPSHa with the NPSH required on the pump curve at the same flow, and keep a margin above it. Even at sea level with cold water, no suction pump can lift water more than 33.2 ft, and real limits sit well below that.
TDH Meaning, Accuracy and Pump Choice
Each answer below works fresh numbers through the same total dynamic head calculator math and pipe data used in the cases above.
What is total dynamic head?
Total dynamic head is the total energy per pound of water a pump must add, stated in feet. It sums elevation, end pressure as head, pipe friction and fitting losses at one flow rate, so a total dynamic head calculator answer shifts with flow.
Feet of head work for any liquid, while psi depends on density. A pump making 111.4 ft lifts water 111.4 ft, which equals 48.2 psi of total dynamic head calculator output in water.
The TDH meaning stays the same for clear water, brine or light oil, which is why a total dynamic head calculator reports feet first.
How do you calculate total dynamic head?
Add elevation, pressure head, pipe friction and fitting losses at your design flow, in that order, for any total dynamic head calculator check by hand.
For a 25 GPM irrigation line rising 20 ft to sprinklers needing 40 psi, the pressure head is 40 × 2.309 = 92.4 ft, so static head is 112.4 ft.
Then 300 ft of 1-1/2 in Schedule 40 PVC at C 150 loses 11.22 ft, and three elbows and a gate valve add 0.48 ft. The total dynamic head is 124.0 ft, which needs 1.31 brake hp and a 1-1/2 HP motor at 60% efficiency.
What is the difference between static head and total dynamic head?
Static head is the part that does not change with flow, which is elevation plus end pressure. Total dynamic head adds the friction and fitting losses, which grow with roughly the square of the flow.
The 40 GPM surface pump case holds 104.3 ft of static head at any flow. With its fittings, the dynamic part is 1.88 ft at 20 GPM, 7.09 ft at 40 GPM and 15.43 ft at 60 GPM, so TDH runs from 106.1 ft to 119.7 ft over that range.
How accurate is the pump total dynamic head TDH calculator?
A total dynamic head calculator is only as good as the elevation, pressure and pipe data behind it, and friction is the least sensitive of the three.
In the 40 GPM case, an old PVC line at C 130 instead of 150 raises friction 30%, from 3.97 to 5.17 ft, yet moves TDH only 1.1%, from 111.36 to 112.56 ft.
A wrong elevation or end pressure moves the answer foot for foot, and a missed foot valve costs 1.81 ft.
Hazen-Williams also fits only water near room temperature, so very hot water and other liquids drift from a total dynamic head calculator estimate.
Can I use this calculator for fluids other than water?
Water-thin liquids work with specific gravity, but viscous ones do not. Specific gravity changes pressure head and power, so 30 psi of brine at SG 1.2 is 57.7 ft of head instead of 69.3 ft. For a given head, power rises with SG.
Friction is the catch for any total dynamic head calculator. Hazen-Williams is a water-only formula, so oils, slurries and glycol mixes need a Darcy-Weisbach friction method with the fluid's viscosity, which Crane TP-410 covers.
Why is velocity head usually much smaller than friction loss?
Velocity head is v² ÷ 2g, and water in a well-sized pipe moves only 3 to 5 ft/s. At 3.82 ft/s in 2 in pipe it is just 0.23 ft, while 150 ft of that same pipe loses 3.97 ft to friction.
Friction builds up along every foot of pipe, while velocity head is a one-time term, so the standard TDH sum leaves it out. Even in 1-1/4 in PVC at 8.58 ft/s it is 1.14 ft against 28.33 ft of friction.
Velocity head matters only for measured TDH, where the suction and discharge pipes differ in size. In the gauge example its change added 0.12 ft to the total dynamic head calculator result.
What pump efficiency should I assume for power calculations?
Use the efficiency printed on the pump curve at your duty point. Until a pump is chosen, a low guess is the safe side in a total dynamic head calculator power estimate, since brake horsepower is water horsepower divided by efficiency.
The 40 GPM case with its fittings needs 1.12 water hp. At 70% that is 1.61 brake hp on a 2 HP motor, but at 50% it is 2.25 brake hp and needs a 3 HP motor, so a 20-point efficiency gap can move you a full motor size.
How do I account for suction lift in TDH calculations?
Count suction lift once, as part of the elevation from the source water level to the top. The 8 ft below the surface pump sits inside its 35 ft total rise, so adding it again would overstate the total dynamic head calculator result by 8 ft.
Suction-side friction also belongs in TDH. The 15 ft suction line and foot valve lose 2.21 ft at 40 GPM, which counts toward both TDH and the NPSH limit.
How do I turn the outlet pressure into head for TDH?
Multiply psi by 2.31 and divide by specific gravity to get feet of head. For water, 30 psi is 69.3 ft, and 1 bar is 33.5 ft, since water weighs 62.37 lb per cubic foot near 60°F.
For TDH to psi, the total dynamic head calculator math runs backward: divide feet by 2.31, so 100 ft of TDH is 43.3 psi in water. The Pump Pressure Calculator converts head and pressure both ways.
Where do I measure the lift from for a well pump?
Measure from the pumping water level, the static level plus drawdown, up to the highest discharge point. A well with water at 60 ft and 20 ft of drawdown lifts from 80 ft down, wherever the pump hangs.
Using the 115 ft pump depth instead adds 35 ft of false head to a total dynamic head calculator estimate. Pump depth matters only for the friction in the drop pipe and for keeping the pump under water while the well draws down.
How do I choose a pump from the TDH?
Plot the duty point, your flow at your TDH, on each pump's curve and choose one whose curve crosses it near the best efficiency point. For the 40 GPM case with fittings that point is 40 GPM at 111.4 ft.
Check the system curve from your total dynamic head calculator run too. At 50 GPM this system needs 115.1 ft, so a pump crossing there runs above plan. A pump whose shutoff head sits below the 104.3 ft static head will never deliver water.