Sound reduction index calculator for wall R from surface mass or measured room levels, plus Rw, C, Ctr and STC from test bands, DnT,w and the level that road traffic leaves inside.
Pick a material or type its density, then the wall thickness and the frequency.
More Options
Room and Traffic
Mass Law by Octave Band
| Frequency | Field R | Normal R | Energy Through |
|---|---|---|---|
| 63 Hz | 39.9 dB | 44.9 dB | 0.0103% |
| 125 Hz | 45.8 dB | 50.8 dB | 0.00262% |
| 250 Hz | 51.8 dB | 56.8 dB | 6.56 × 10⁻⁴% |
| 500 Hz | 57.9 dB | 62.9 dB | 1.64 × 10⁻⁴% |
| 1,000 Hz | 63.9 dB | 68.9 dB | 4.10 × 10⁻⁵% |
| 2,000 Hz | 69.9 dB | 74.9 dB | 1.02 × 10⁻⁵% |
| 4,000 Hz | 75.9 dB | 80.9 dB | 2.56 × 10⁻⁶% |
Step-by-Step Math
- Density = 150 lb/ft³ = 2,402.77 kg/m³
- Surface mass = 2,402.77 kg/m³ × 0.1524 m = 366.18 kg/m²
- R = 20 × log₁₀(366.18 × 500) - 47.4 = 20 × log₁₀(183,091) - 47.4 = 57.85 dB
- Estimated Rw = 37.5 × log₁₀(366.18) - 42 = 54.14, rounded to 54 dB; Ctr = 16 - 9 × log₁₀(366.18) kept within -7 to -1 = -7 dB; C is taken as -1 dB, since the same prediction method puts C at -1 to -2 dB for these walls
- Surface mass for 60 dB = 10 raised to ((60 + 47.4) ÷ 20), ÷ 500 = 468.85 kg/m²; thickness = 468.85 ÷ 2,402.77 = 0.19513 m = 7.68 in
- Quiet-side level = 90.0 dB - 57.9 dB = 32.1 dB
- Sound reduction index at 500 Hz = 57.9 dB
Sound Reduction Index Calculator Values by Wall Material
A 6 in (152 mm) normal-weight concrete wall has a sound reduction index of about 57.9 dB at 500 Hz by the mass law. Its surface mass is 366.2 kg/m², or 75 lb/ft², and only 0.00016% of the sound energy striking it passes through.
In mass law sound reduction index calculator math, R comes from surface mass and frequency alone. It is the sound reduction index equation that solid single walls follow between their low-frequency resonance and their coincidence dip.
R is the sound reduction index in dB, m is surface mass in kg/m² and f is frequency in Hz. The 47.4 dB constant is for field incidence, sound arriving from all angles in a room, and drops to 42.4 dB for sound striking head-on.
Surface mass is density times thickness. Normal-weight concrete at 150 lb/ft³ (2,403 kg/m³) and 6 in thick gives 2,403 × 0.1524 = 366.2 kg/m², and 20 × log₁₀(366.2 × 500) - 47.4 = 57.9 dB.
The table below is a sound reduction index calculator run at field incidence for common single layers. Estimated Rw, the weighted single number, applies only from 150 kg/m², so light sheets carry a band value but no Rw.
| Material | Thickness | Surface mass | R at 125 Hz | R at 500 Hz | R at 2,000 Hz | Estimated Rw |
|---|---|---|---|---|---|---|
| Concrete, normal weight | 4 in (102 mm) | 244.1 kg/m² (50.0 lb/ft²) | 42.3 dB | 54.3 dB | 66.4 dB | 48 dB |
| Concrete, normal weight | 8 in (203 mm) | 488.2 kg/m² (100.0 lb/ft²) | 48.3 dB | 60.4 dB | 72.4 dB | 59 dB |
| Solid clay brick | 4 in (102 mm) | 193.0 kg/m² (39.5 lb/ft²) | 40.3 dB | 52.3 dB | 64.3 dB | 44 dB |
| Steel plate | 1/8 in (3.2 mm) | 24.9 kg/m² (5.1 lb/ft²) | 22.5 dB | 34.5 dB | 46.6 dB | Under 150 kg/m² |
| Glass | 1/4 in (6.4 mm) | 15.9 kg/m² (3.3 lb/ft²) | 18.6 dB | 30.6 dB | 42.6 dB | Under 150 kg/m² |
| Gypsum board | 5/8 in (15.9 mm) | 12.7 kg/m² (2.6 lb/ft²) | 16.6 dB | 28.7 dB | 40.7 dB | Under 150 kg/m² |
| Pine board | 3/4 in (19 mm) | 9.5 kg/m² (2.0 lb/ft²) | 14.1 dB | 26.2 dB | 38.2 dB | Under 150 kg/m² |
Every sound reduction index calculator figure from the mass law is an upper limit for a real wall. Glass, steel and gypsum board all lose several dB near their coincidence frequency, and gaps at the edges leak more than the wall itself.
The 6 dB gain per doubling of frequency explains why walls stop treble far better than bass. The same 6 in concrete wall gives 45.8 dB at 125 Hz against 69.9 dB at 2,000 Hz, a 24 dB spread across four octaves.
Reaching 60 dB at 500 Hz in solid concrete needs 468.8 kg/m², which is 7.7 in (195 mm) of wall, 1.7 in more than 6 in. A cavity wall with two separated leaves usually gets there with much less weight.
Doubling Wall Mass Gains 11 dB of Rw, Not 6
For solid walls from 150 kg/m², doubling the surface mass raises the estimated Rw by 11.3 dB. The mass law at any single frequency gains only 6 dB, so quoting 4 to 6 dB per doubling undersells heavy walls.
Rw is the weighted sound reduction index in dB and m is surface mass in kg/m². This prediction for single homogeneous walls comes from EN 12354-1 Annex B, valid from 150 kg/m², where heavy walls have no strong coincidence dip in the rated range.
| Surface mass | Mass law R at 500 Hz | Estimated Rw | Rw + Ctr |
|---|---|---|---|
| 150 kg/m² (30.7 lb/ft²) | 50.1 dB | 40 dB | 36 dB |
| 300 kg/m² (61.4 lb/ft²) | 56.1 dB | 51 dB | 45 dB |
| 600 kg/m² (122.9 lb/ft²) | 62.1 dB | 62 dB | 55 dB |
In sound reduction index calculator terms, the 37.5 slope means each 10% more mass adds about 1.6 dB of Rw. A 4 in concrete wall at 244 kg/m² lands at Rw 48, and 8 in at 488 kg/m² lands at Rw 59, an 11 dB step for one doubling.
The traffic term Ctr follows 16 - 9 × log₁₀(m), kept between -7 and -1 dB, while C for speech is taken as -1 dB. Walls reach the -7 dB floor from about 316 kg/m², so 6 and 8 in concrete both lose 7 dB against road noise.
Room Levels to R With the Level Method
A 90 dB source room, a 48 dB receiving room, 120 sq ft (11.1 m²) of wall and 100 sabins (9.3 m²) of absorption give R = 42.8 dB. The level difference is 42 dB, and the area term adds 0.8 dB.
L1 and L2 are the energy-average room levels, S is the shared wall area and A is the receiving room absorption, in matching units. Any sound reduction index calculator in level-method form rests on this test equation.
In the sound reduction index calculator equation, the area term corrects for the room, not the wall. Doubling the wall area to 240 sq ft with the same levels raises R to 45.8 dB, because a larger wall had to pass the same sound through more surface.
Doubling the absorption to 200 sabins drops R to 39.8 dB, since a deader receiving room hides part of what the wall lets through. Measure absorption from the reverb time when you can, since A = 0.161 × V ÷ T in metric units.
The same sound reduction index calculator equation runs backward for design. To bring a 90 dB room down to 35 dB next door with that wall and room, the partition needs R 55.8 dB, and a wall rated R 42 leaves 48.8 dB on the quiet side.
Field results include flanking through floors, ceilings and ducts, so a measured R′ often reads a few dB below the lab R of the same wall. Set any sound reduction index calculator target a few dB above the bare requirement.
Weighted Rw, C and Ctr From a Test Report
A wall with octave-band R of 38, 43, 49, 56 and 61 dB from 125 to 2,000 Hz rates Rw 54 (-2; -6) dB under ISO 717-1. That means Rw + C is 52 dB for speech and Rw + Ctr is 48 dB for traffic.
For a weighted sound reduction index calculator result, the ISO 717-1 octave reference curve is 36, 45, 52, 55 and 56 dB. It moves in 1 dB steps until the bands falling below it add up to 10 dB or less, and Rw is the shifted curve's value at 500 Hz.
| Band | Test R | Shifted reference curve | Shortfall |
|---|---|---|---|
| 125 Hz | 38 dB | 38 dB | 0 dB |
| 250 Hz | 43 dB | 47 dB | 4 dB |
| 500 Hz | 49 dB | 54 dB | 5 dB |
| 1,000 Hz | 56 dB | 57 dB | 1 dB |
| 2,000 Hz | 61 dB | 58 dB | 0 dB |
In this sound reduction index calculator example, the shortfalls at 250, 500 and 1,000 Hz total exactly 10 dB, so the curve stops 2 dB above the reference and Rw = 52 + 2 = 54 dB.
With one-third octave data from 100 to 3,150 Hz, the limit becomes 32 dB across 16 bands, and the curve runs from 33 dB at 100 Hz up to 56 dB from 1,250 Hz.
C and Ctr weight the same bands against a pink-noise spectrum and a road-traffic spectrum. Each term is the energy sum of the spectrum minus R in every band, turned back into dB, minus Rw, rounded to a whole number.
Ctr runs negative because traffic carries most of its energy at low frequencies, where walls are weakest.
Compare facade walls and windows on the Rw + Ctr sound reduction index calculator rating, since two walls with equal Rw can differ by several dB against a road.
A sound reduction index calculator in Excel needs one row per band. Add a shifted curve column, a MAX(0, curve - R) shortfall column and a loop or Goal Seek that lowers the shift until the shortfall sum reaches the limit.
STC vs Sound Reduction Index on One Spectrum
STC and Rw land within 2 points on the spectra below, but they rate different bands and use different rules. STC from ASTM E413 covers 125 to 4,000 Hz, while Rw covers 100 to 3,150 Hz, and only STC caps any single band at 8 dB short.
Each spectrum below is a sound reduction index calculator example that rises evenly, then has one band changed. The ratings come from the same third-octave data, so every difference traces back to the band each method reads or ignores.
| Spectrum | Rw | Rw + C | Rw + Ctr | STC |
|---|---|---|---|---|
| Even rise, 30 to 61 dB | 51 dB | 49 dB | 45 dB | 51 |
| Same, 22 dB at 100 Hz | 50 dB | 47 dB | 41 dB | 51 |
| Same, 45 dB at 4,000 Hz | 51 dB | 49 dB | 45 dB | 49 |
A weak 100 Hz band leaves STC at 51 because STC never reads it, yet Rw + Ctr falls 4 dB to 41. For music rooms or a facade facing traffic, STC alone hides a bass problem that Rw + Ctr reveals.
A 45 dB dip at 4,000 Hz pulls STC down 2 points to 49 through the 8 dB rule, while Rw stays 51 because ISO 717-1 stops at 3,150 Hz. The US contour, per the USG summary of ASTM E413, allows 32 dB of total shortfall.
Sound reduction index vs transmission loss is only a naming difference in any sound reduction index calculator. Transmission loss, TL, is the US term for the same per-band quantity R, measured by ASTM E90 in the US and ISO 10140 elsewhere.
DnT,w From Rw and Indoor Traffic Noise
An Rw 50 wall of 80 sq ft (7.4 m²) into a 1,060 ft³ (30 m³) room gives DnT,w 51 dB. DnT,w is the field level difference standardized to a 0.5 s reverb time, the figure many building regulations ask for.
V is the receiving room volume in m³ and S is the shared wall area in m². The 0.32 in this sound reduction index calculator step comes from 0.161 ÷ 0.5 s, so this way to calculate DnT,w from Rw ignores flanking, which real buildings usually add.
| Wall area | Room volume | DnT,w for an Rw 50 wall |
|---|---|---|
| 80 sq ft (7.4 m²) | 1,060 ft³ (30.0 m³) | 51 dB |
| 120 sq ft (11.1 m²) | 1,060 ft³ (30.0 m³) | 49 dB |
| 160 sq ft (14.9 m²) | 1,060 ft³ (30.0 m³) | 48 dB |
| 80 sq ft (7.4 m²) | 2,120 ft³ (60.0 m³) | 54 dB |
| 80 sq ft (7.4 m²) | 3,000 ft³ (85.0 m³) | 56 dB |
Bigger shared walls lower DnT,w and bigger receiving rooms raise it. A 160 sq ft wall into the same room drops to 48 dB, 3 dB below the 80 sq ft case, which matters when a long party wall sits next to a narrow bedroom.
Indoor noise from outside follows the same area and absorption logic, using Rw + Ctr. Outdoor traffic at 72 dB(A) against an Rw 51 (-6) facade of 80 sq ft, in a 1,060 ft³ room at 0.5 s, gives 72 - 45 - 1.1 = 25.9 dB(A) inside.
The sound reduction index calculator area term, 10 × log₁₀(S ÷ A), is -1.1 dB there, from 7.4 m² of facade and 9.7 m² of absorption. The WKC Group internal noise method uses the same relation from BS EN 12354-3.
SRI Meaning and the NRC Calculation
These two questions come up beside every sound reduction index calculator search, and they are easy to confuse because one rates blocking and the other rates absorbing.
What is the sound reduction index (SRI)?
The sound reduction index, SRI or R, is how many decibels a wall or panel cuts from the sound passing through it, measured in each frequency band. An R of 40 dB lets 1/10,000 of the striking sound energy through.
Every 10 dB of R cuts the passing energy tenfold, so R 50 passes one tenth as much energy as R 40. Lab values are measured on the wall alone; airborne sound reduction index results in a finished building, written R′, include flanking.
How do you calculate noise reduction coefficient?
The noise reduction coefficient, NRC, is the average of a material's absorption coefficients at 250, 500, 1,000 and 2,000 Hz, rounded to the nearest 0.05. Bands of 0.45, 0.65, 0.90 and 0.90 average 0.725 and rate NRC 0.75.
NRC measures how much sound a surface absorbs inside a room, not how much it blocks, so a soft panel can score NRC 1.00 with an R near zero. The Noise Reduction Coefficient Calculator works through those bands and room reverb.