Scupper Size Calculator for the clear width of roof scuppers from roof area, rainfall and water head, with end contractions, drain minimum width, closed box flow and ponding loads.
Head is the water depth above the scupper's bottom edge when it runs full.
Scupper Type and Count
Live Scupper Diagram
Scupper Size Chart
Roof Drain Sizing Chart
Step-by-Step Scupper Math
Rainfall, Roof Area and Scupper Size Calculator Widths
A 2,000 sq ft roof at 4 in/hr of rain needs an 11 in wide scupper at a 2 in water head. That opening carries 83.1 GPM, the runoff from 2,000 sq ft times 4 in/hr times 0.01039 GPM per sq ft per in/hr.
Q is the runoff in gallons per minute, A is the roof area drained in square feet and i is the design rainfall in inches per hour. The 0.01039 converts 1 in/hr falling on 1 sq ft into GPM.
The table runs that scupper size calculator math for primary scuppers at a 2 in head, with end contractions and the plumbing-code minimum width both applied. Widths are whole inches to build.
| Roof Area per Scupper | 2 in/hr | 3 in/hr | 4 in/hr | 6 in/hr |
|---|---|---|---|---|
| 1,000 sq ft | 7 in (code) | 10 in (code) | 10 in (code) | 10 in (code) |
| 2,000 sq ft | 10 in (code) | 10 in (code) | 11 in | 16 in |
| 5,000 sq ft | 13 in | 19 in | 25 in | 38 in |
| 10,000 sq ft | 25 in | 38 in | 50 in | 74 in |
| 20,000 sq ft | 50 in | 74 in | 99 in | 148 in, split it |
In a scupper size calculator table, cells marked code are set by the roof-drain circumference rule, not by flow. Small roofs rarely need the hydraulic width, so the code minimum decides most scuppers up to about 2,000 sq ft in the table.
Scupper size calculator widths grow in direct proportion to rainfall. Use the 100-year, 60-minute rate your plumbing code requires for the site, or the rate the engineer of record sets, rather than a national average.
Scupper size calculator widths over about 4 ft usually mean the roof should drain through more than one scupper. Two scuppers on the 12,000 sq ft, 4 in/hr roof at a 2 in head each carry 249.4 GPM and need 30 in each.
End Contractions Change the Width You Build
An 11 in scupper at a 3 in head passes 162.1 GPM, not the 171.5 GPM the simple weir formula predicts. The two side walls pinch the flow, and that 5.5% loss can leave a just-big-enough opening short.
Q is the flow in GPM, W is the clear opening width in inches and h is the water head above the scupper bottom in inches. The 0.2h is the end contraction, 0.1h at each side wall.
The widely quoted scupper size calculator shortcut, width equals GPM divided by 3 times head to the 1.5, drops that term. For the 166.2 GPM overflow on a 2,000 sq ft roof at 4 in/hr and a 3 in head, it gives 10.66 in, rounded to 11 in.
The contracted width is 11.26 in, so the scupper to build is 12 in, which passes 177.7 GPM. Any scupper size calculator result rounded to the next inch without the contraction can land on the wrong side.
The contracted formula matches the published code table. California Plumbing Code Appendix D, Table D104.1 lists a 6 in scupper at a 1 in head as 17 GPM and a 36 in scupper as 107 GPM, based on a rectangular weir with end contractions.
| Scupper Width | 1 in Head | 2 in Head | 3 in Head | 4 in Head |
|---|---|---|---|---|
| 4 in | 11.4 GPM | 30.5 GPM | 53.0 GPM | 76.8 GPM |
| 6 in | 17.4 GPM | 47.5 GPM | 84.2 GPM | 124.8 GPM |
| 8 in | 23.4 GPM | 64.5 GPM | 115.4 GPM | 172.8 GPM |
| 12 in | 35.4 GPM | 98.4 GPM | 177.7 GPM | 268.8 GPM |
| 18 in | 53.4 GPM | 149.3 GPM | 271.2 GPM | 412.8 GPM |
| 24 in | 71.4 GPM | 200.3 GPM | 364.8 GPM | 556.8 GPM |
| 36 in | 107.4 GPM | 302.1 GPM | 551.8 GPM | 844.8 GPM |
That scupper size chart doubles as a list of standard scupper sizes. At 4 in/hr with no safety factor, a 6 in scupper at a 2 in head drains about 1,143 sq ft, a 12 in drains 2,368 sq ft and a 24 in drains 4,819 sq ft.
In scupper size calculator math, the contraction matters most on narrow, deep openings. On a 4 in scupper at a 4 in head it cuts flow by 20%, while on a 36 in scupper at a 1 in head the loss is under 1%.
Overflow Scupper Size at Twice the Rain
In scupper size calculator math, an overflow scupper at 2 times the design rain is twice as wide as a primary scupper at the same head. On a 2,000 sq ft roof at 4 in/hr and a 2 in head, that is 20 in instead of 11 in.
The doubling has a basis. Plumbing codes size both primary and overflow drainage for the 100-year, 60-minute rain.
ASCE 7, by contrast, recommends the 100-year, 15-minute rate for overflow, roughly double the hourly rate in most US locations, as Patterson and Mehta explain in IIBEC Interface.
| Roof Area at 4 in/hr | Head | Primary, 1.00x | Overflow, 2.00x | Overflow Flow |
|---|---|---|---|---|
| 2,000 sq ft | 2 in | 11 in | 20 in | 166.2 GPM |
| 2,000 sq ft | 3 in | 10 in (code) | 12 in | 166.2 GPM |
| 10,000 sq ft | 2 in | 50 in | 99 in | 831.2 GPM |
| 10,000 sq ft | 3 in | 28 in | 54 in | 831.2 GPM |
Primary drains get no credit in an overflow scupper size calculator estimate. Under IBC Section 1503.4.2, flow through the primary drains is not counted when overflow scuppers are sized, because the overflow exists for when those drains clog.
A roof overflow scupper also sits higher than the primary drain inlet so it only runs in a backup. That inlet height adds standing water to the roof, which the ponding load in the next section has to include.
The 1.25 and 1.50 scupper size calculator factors are a middle ground for primary scuppers where debris or a missed rainfall update is a risk. Each step widens the opening in direct proportion before the contraction and rounding.
Head Depth and Ponding Load
Raising the design head from 2 in to 4 in cuts the overflow scupper for a 5,000 sq ft roof at 4 in/hr from 50 in to 19 in. The trade is water on the roof, which rises from 10.4 psf to 20.8 psf of load.
| Head | Width to Build, 2.00x | Water Load From Head | Water on 5,000 sq ft | Ponded Volume |
|---|---|---|---|---|
| 1 in | 139 in | 5.2 psf | 26,000 lb | 3,117 gal |
| 1.5 in | 76 in | 7.8 psf | 39,000 lb | 4,675 gal |
| 2 in | 50 in | 10.4 psf | 52,000 lb | 6,234 gal |
| 3 in | 28 in | 15.6 psf | 78,000 lb | 9,351 gal |
| 4 in | 19 in | 20.8 psf | 104,000 lb | 12,468 gal |
In scupper size calculator terms, head is the depth of water above the scupper's bottom edge when it runs full, not the parapet height. Width falls with head to the 1.5 power, so each added inch of head buys a much narrower opening.
The structural limit is the full rain load, not head alone. ASCE 7 gives R = 5.2(ds + dh) in psf, where ds is the static head from the roof to the overflow inlet and dh is the hydraulic head.
R is the rain load in psf, 5.2 is the weight of 1 in of water per square foot, ds is the inlet height above the roof in inches and dh is the head above the inlet in inches.
An overflow scupper set 2 in above the roof with a 3 in head loads the roof at 26.0 psf, not the 15.6 psf from head alone. Over 2,000 sq ft that is 52,000 lb of water, 20,800 lb more than a scupper size calculator total built on head alone.
Code Minimum Width From the Roof Drain
A scupper must be at least as wide as the circumference of the roof drain the code would require for the same area. For 4,000 sq ft at 3 in/hr that drain is 4 in, so the scupper is at least 12 9/16 in wide, built at 13 in.
That rule appears in plumbing code scupper sections along with a 4 in minimum opening height. In this case it governs, since a 3 in head only needs 8.6 in with contractions.
The roof drain sizing chart below divides each drain's rated area at 1 in/hr by the rainfall. The areas are the circular leader capacities used for roof drain sizing in the International Plumbing Code.
| Roof Drain | Max Area at 1 in/hr | At 2 in/hr | At 4 in/hr | At 6 in/hr | Min Scupper Width |
|---|---|---|---|---|---|
| 2 in | 2,880 sq ft | 1,440 sq ft | 720 sq ft | 480 sq ft | 6 5/16 in |
| 3 in | 8,800 sq ft | 4,400 sq ft | 2,200 sq ft | 1,467 sq ft | 9 7/16 in |
| 4 in | 18,400 sq ft | 9,200 sq ft | 4,600 sq ft | 3,067 sq ft | 12 9/16 in |
| 5 in | 34,600 sq ft | 17,300 sq ft | 8,650 sq ft | 5,767 sq ft | 15 11/16 in |
| 6 in | 54,000 sq ft | 27,000 sq ft | 13,500 sq ft | 9,000 sq ft | 18 7/8 in |
| 8 in | 116,000 sq ft | 58,000 sq ft | 29,000 sq ft | 19,333 sq ft | 25 1/8 in |
For a scupper size calculator check, find the smallest drain whose area at your rainfall covers the roof area per scupper. On 2,000 sq ft at 4 in/hr that is the 3 in drain, so no scupper on that roof can be narrower than 9 7/16 in.
Past 29,000 sq ft per scupper at 4 in/hr, no drain in the table covers the area, so split the roof between more scuppers. For drain counts and leader sizes on the same roof, the Roof Drainage Calculator covers that side.
Closed Box Scuppers and Orifice Flow
A closed box scupper 4 in high runs as an orifice once the head passes 4 in, and then needs a wider box. For the 5,000 sq ft overflow at 4 in/hr and a 6 in head, an open channel needs 10.63 in with contractions while the 4 in box needs 12.00 in.
Q is the flow in GPM, W is the box width and H its opening height in inches, and h is the head above the box bottom in inches. The 1.870 folds in a 0.6 discharge coefficient and unit conversions.
| Head | Open-Top Channel | Closed Box, 4 in High | Closed Box, 6 in High |
|---|---|---|---|
| 4 in | 18.12 in | 18.12 in | 18.12 in |
| 5 in | 13.39 in | 13.85 in | 13.39 in |
| 6 in | 10.63 in | 12.00 in | 10.63 in |
| 8 in | 7.72 in | 9.79 in | 7.15 in |
Weir widths in this table include the 0.2h contraction, while orifice widths do not, since the 0.6 coefficient already covers the entry loss. None include the code minimum or rounding to a whole inch.
Up to its own height, a box flows as a weir, so heads at or below the box top give the same scupper size calculator width as an open channel.
Where the parapet allows, make the box tall enough to stay a weir in any scupper size calculator check.
California Plumbing Code Appendix D asks for an opening at least two times the design head, so a 3 in head calls for a 6 in tall box, above the general 4 in minimum.
Millimeters, L/s and mm/hr Results
A 200 m² roof at 100 mm/hr of rain sheds 5.56 L/s, and an overflow scupper at 2 times that flow with a 50 mm head needs 550 mm of clear width. In a metric scupper size calculator estimate, runoff is area times rainfall divided by 3,600.
In metric, Q is the flow in m³/s, W the clear width in meters and h the head in meters. The 1.841 is the same weir coefficient as 3.0 in US units, so either system gives the same scupper.
| Roof Area | Rainfall | Head | Factor | Design Flow | Width With Contractions | Code Drain |
|---|---|---|---|---|---|---|
| 200 m² | 100 mm/hr | 50 mm | 1.00x | 5.56 L/s | 280 mm | 76 mm (240 mm wide) |
| 200 m² | 100 mm/hr | 50 mm | 2.00x | 11.11 L/s | 550 mm | 76 mm (240 mm wide) |
| 500 m² | 150 mm/hr | 75 mm | 2.00x | 41.67 L/s | 1,120 mm | 127 mm (399 mm wide) |
| 1,000 m² | 100 mm/hr | 50 mm | 2.00x | 55.56 L/s | 2,710 mm | 152 mm (479 mm wide) |
Metric scupper size calculator widths here round up to the next 10 mm. For scupper size in mm to inches, divide by 25.4, so the 550 mm overflow opening is 21 5/8 in and the 280 mm primary is 11 in.
In any metric scupper size calculator result, a millimeter of head equals about 1 kg/m² of water. The 50 mm head above weighs 50 kg/m² on the roof, and over 200 m² that is 10,000 kg before any static head below the inlet.
Asked When Sizing a Scupper
These three questions come up most when a flat roof scupper is specified. Each answer uses a roof not already worked above, so the numbers add a new case.
How are scuppers sized?
Scuppers are sized on flow, then checked against the code width. First find the runoff from roof area and rainfall, then the width that passes it at the design head, then compare with the circumference of the roof drain the code requires.
For a 3,600 sq ft roof at 3 in/hr, runoff is 112.2 GPM. At a 2 in head that needs 13.22 in, or 13.62 in with contractions, while the code drain for 3,600 sq ft at 3 in/hr is 4 in, setting a 12 9/16 in minimum.
The larger figure wins in a scupper size calculator check, so build that scupper 14 in wide and at least 4 in high. The same steps size the scupper drain for each roof area, whether it serves as the primary outlet or the overflow.
How do you calculate scupper width?
Divide the design flow in GPM by 3.0 times the head in inches raised to the 1.5 power, then add 0.2 times the head for the side walls. Round the scupper size calculator result up to a whole inch you can build.
For 249.4 GPM at a 2 in head, 2 to the 1.5 power is 2.828, so 249.4 divided by 8.485 gives 29.39 in. Adding 0.4 in for contractions makes 29.79 in, so the scupper is 30 in wide.
How do I choose a scupper?
Choose by role first, then by head. A primary scupper carries the design rain and sits at the roof surface, while an overflow scupper sits above the primary drain inlet and is commonly sized for twice the rain.
Then settle the head the roof can carry. On a 5,000 sq ft roof at 4 in/hr, accepting 3 in of head instead of 2 in cuts the overflow from 50 in to 28 in but adds 5.2 psf of water across the roof.
Use an open-top channel where the parapet allows it, since it never switches to orifice flow. A closed through-wall box should be at least twice the head in height and never under 4 in.