Scupper Size Calculator

Updated

Scupper Size Calculator for the clear width of roof scuppers from roof area, rainfall and water head, with end contractions, drain minimum width, closed box flow and ponding loads.

Quick Setup

Head is the water depth above the scupper's bottom edge when it runs full.

sq ft
in/hr
in
in
Scupper Type and Count1 open-top scupper
scuppers
in
in
Required Clear Opening
11 5/16 in Scupper Width
Exact 11.264 in clear width
166.23 GPM Design Flow
Rain Runoff Before Factor83.12 GPM
In Liters per Second10.49 L/s
Roof area times rainfall times the safety factor. Overflow scuppers are often sized at twice the design rain.
12 in Width to Build
Code Minimum, Drain Circumference9 7/16 in
Roof Drain Sized for This Area3 in drain
The larger of the required width rounded up and the circumference of a roof drain sized for this same roof area.
10 11/16 in Width Without Contractions
Side-Wall Contraction Allowance5/8 in
Spare Flow at Width to Build11.47 GPM
Water pulls in at both side walls, so the opening flows as if it were 0.2 × head narrower than its real width.
15.60 psf Roof Rain Load
Water on the Roof31,200 lb
Ponded Volume3,740 gal
Static head plus flow head is the water depth when the primary drains are blocked. Each inch adds 5.2 psf.
Live Scupper DiagramOpening and water level
Scupper Size ChartRoof area per scupper at 4 in/hr, 2.00×
Roof Drain Sizing ChartDrain size and scupper width
Step-by-Step Scupper MathWith your numbers
    Scupper Sized
    Openings must also be at least 4 in high and twice the head. Set the overflow scupper inlet above the primary drain so it only runs when the drains back up.

    Rainfall, Roof Area and Scupper Size Calculator Widths

    A 2,000 sq ft roof at 4 in/hr of rain needs an 11 in wide scupper at a 2 in water head. That opening carries 83.1 GPM, the runoff from 2,000 sq ft times 4 in/hr times 0.01039 GPM per sq ft per in/hr.

    Q is the runoff in gallons per minute, A is the roof area drained in square feet and i is the design rainfall in inches per hour. The 0.01039 converts 1 in/hr falling on 1 sq ft into GPM.

    The table runs that scupper size calculator math for primary scuppers at a 2 in head, with end contractions and the plumbing-code minimum width both applied. Widths are whole inches to build.

    Roof Area per Scupper2 in/hr3 in/hr4 in/hr6 in/hr
    1,000 sq ft7 in (code)10 in (code)10 in (code)10 in (code)
    2,000 sq ft10 in (code)10 in (code)11 in16 in
    5,000 sq ft13 in19 in25 in38 in
    10,000 sq ft25 in38 in50 in74 in
    20,000 sq ft50 in74 in99 in148 in, split it

    In a scupper size calculator table, cells marked code are set by the roof-drain circumference rule, not by flow. Small roofs rarely need the hydraulic width, so the code minimum decides most scuppers up to about 2,000 sq ft in the table.

    Scupper size calculator widths grow in direct proportion to rainfall. Use the 100-year, 60-minute rate your plumbing code requires for the site, or the rate the engineer of record sets, rather than a national average.

    Scupper size calculator widths over about 4 ft usually mean the roof should drain through more than one scupper. Two scuppers on the 12,000 sq ft, 4 in/hr roof at a 2 in head each carry 249.4 GPM and need 30 in each.

    End Contractions Change the Width You Build

    An 11 in scupper at a 3 in head passes 162.1 GPM, not the 171.5 GPM the simple weir formula predicts. The two side walls pinch the flow, and that 5.5% loss can leave a just-big-enough opening short.

    Q is the flow in GPM, W is the clear opening width in inches and h is the water head above the scupper bottom in inches. The 0.2h is the end contraction, 0.1h at each side wall.

    The widely quoted scupper size calculator shortcut, width equals GPM divided by 3 times head to the 1.5, drops that term. For the 166.2 GPM overflow on a 2,000 sq ft roof at 4 in/hr and a 3 in head, it gives 10.66 in, rounded to 11 in.

    The contracted width is 11.26 in, so the scupper to build is 12 in, which passes 177.7 GPM. Any scupper size calculator result rounded to the next inch without the contraction can land on the wrong side.

    The contracted formula matches the published code table. California Plumbing Code Appendix D, Table D104.1 lists a 6 in scupper at a 1 in head as 17 GPM and a 36 in scupper as 107 GPM, based on a rectangular weir with end contractions.

    Scupper Width1 in Head2 in Head3 in Head4 in Head
    4 in11.4 GPM30.5 GPM53.0 GPM76.8 GPM
    6 in17.4 GPM47.5 GPM84.2 GPM124.8 GPM
    8 in23.4 GPM64.5 GPM115.4 GPM172.8 GPM
    12 in35.4 GPM98.4 GPM177.7 GPM268.8 GPM
    18 in53.4 GPM149.3 GPM271.2 GPM412.8 GPM
    24 in71.4 GPM200.3 GPM364.8 GPM556.8 GPM
    36 in107.4 GPM302.1 GPM551.8 GPM844.8 GPM

    That scupper size chart doubles as a list of standard scupper sizes. At 4 in/hr with no safety factor, a 6 in scupper at a 2 in head drains about 1,143 sq ft, a 12 in drains 2,368 sq ft and a 24 in drains 4,819 sq ft.

    In scupper size calculator math, the contraction matters most on narrow, deep openings. On a 4 in scupper at a 4 in head it cuts flow by 20%, while on a 36 in scupper at a 1 in head the loss is under 1%.

    Overflow Scupper Size at Twice the Rain

    In scupper size calculator math, an overflow scupper at 2 times the design rain is twice as wide as a primary scupper at the same head. On a 2,000 sq ft roof at 4 in/hr and a 2 in head, that is 20 in instead of 11 in.

    The doubling has a basis. Plumbing codes size both primary and overflow drainage for the 100-year, 60-minute rain.

    ASCE 7, by contrast, recommends the 100-year, 15-minute rate for overflow, roughly double the hourly rate in most US locations, as Patterson and Mehta explain in IIBEC Interface.

    Roof Area at 4 in/hrHeadPrimary, 1.00xOverflow, 2.00xOverflow Flow
    2,000 sq ft2 in11 in20 in166.2 GPM
    2,000 sq ft3 in10 in (code)12 in166.2 GPM
    10,000 sq ft2 in50 in99 in831.2 GPM
    10,000 sq ft3 in28 in54 in831.2 GPM

    Primary drains get no credit in an overflow scupper size calculator estimate. Under IBC Section 1503.4.2, flow through the primary drains is not counted when overflow scuppers are sized, because the overflow exists for when those drains clog.

    A roof overflow scupper also sits higher than the primary drain inlet so it only runs in a backup. That inlet height adds standing water to the roof, which the ponding load in the next section has to include.

    The 1.25 and 1.50 scupper size calculator factors are a middle ground for primary scuppers where debris or a missed rainfall update is a risk. Each step widens the opening in direct proportion before the contraction and rounding.

    Head Depth and Ponding Load

    Raising the design head from 2 in to 4 in cuts the overflow scupper for a 5,000 sq ft roof at 4 in/hr from 50 in to 19 in. The trade is water on the roof, which rises from 10.4 psf to 20.8 psf of load.

    HeadWidth to Build, 2.00xWater Load From HeadWater on 5,000 sq ftPonded Volume
    1 in139 in5.2 psf26,000 lb3,117 gal
    1.5 in76 in7.8 psf39,000 lb4,675 gal
    2 in50 in10.4 psf52,000 lb6,234 gal
    3 in28 in15.6 psf78,000 lb9,351 gal
    4 in19 in20.8 psf104,000 lb12,468 gal

    In scupper size calculator terms, head is the depth of water above the scupper's bottom edge when it runs full, not the parapet height. Width falls with head to the 1.5 power, so each added inch of head buys a much narrower opening.

    The structural limit is the full rain load, not head alone. ASCE 7 gives R = 5.2(ds + dh) in psf, where ds is the static head from the roof to the overflow inlet and dh is the hydraulic head.

    R is the rain load in psf, 5.2 is the weight of 1 in of water per square foot, ds is the inlet height above the roof in inches and dh is the head above the inlet in inches.

    An overflow scupper set 2 in above the roof with a 3 in head loads the roof at 26.0 psf, not the 15.6 psf from head alone. Over 2,000 sq ft that is 52,000 lb of water, 20,800 lb more than a scupper size calculator total built on head alone.

    Code Minimum Width From the Roof Drain

    A scupper must be at least as wide as the circumference of the roof drain the code would require for the same area. For 4,000 sq ft at 3 in/hr that drain is 4 in, so the scupper is at least 12 9/16 in wide, built at 13 in.

    That rule appears in plumbing code scupper sections along with a 4 in minimum opening height. In this case it governs, since a 3 in head only needs 8.6 in with contractions.

    The roof drain sizing chart below divides each drain's rated area at 1 in/hr by the rainfall. The areas are the circular leader capacities used for roof drain sizing in the International Plumbing Code.

    Roof DrainMax Area at 1 in/hrAt 2 in/hrAt 4 in/hrAt 6 in/hrMin Scupper Width
    2 in2,880 sq ft1,440 sq ft720 sq ft480 sq ft6 5/16 in
    3 in8,800 sq ft4,400 sq ft2,200 sq ft1,467 sq ft9 7/16 in
    4 in18,400 sq ft9,200 sq ft4,600 sq ft3,067 sq ft12 9/16 in
    5 in34,600 sq ft17,300 sq ft8,650 sq ft5,767 sq ft15 11/16 in
    6 in54,000 sq ft27,000 sq ft13,500 sq ft9,000 sq ft18 7/8 in
    8 in116,000 sq ft58,000 sq ft29,000 sq ft19,333 sq ft25 1/8 in

    For a scupper size calculator check, find the smallest drain whose area at your rainfall covers the roof area per scupper. On 2,000 sq ft at 4 in/hr that is the 3 in drain, so no scupper on that roof can be narrower than 9 7/16 in.

    Past 29,000 sq ft per scupper at 4 in/hr, no drain in the table covers the area, so split the roof between more scuppers. For drain counts and leader sizes on the same roof, the Roof Drainage Calculator covers that side.

    Closed Box Scuppers and Orifice Flow

    A closed box scupper 4 in high runs as an orifice once the head passes 4 in, and then needs a wider box. For the 5,000 sq ft overflow at 4 in/hr and a 6 in head, an open channel needs 10.63 in with contractions while the 4 in box needs 12.00 in.

    Q is the flow in GPM, W is the box width and H its opening height in inches, and h is the head above the box bottom in inches. The 1.870 folds in a 0.6 discharge coefficient and unit conversions.

    HeadOpen-Top ChannelClosed Box, 4 in HighClosed Box, 6 in High
    4 in18.12 in18.12 in18.12 in
    5 in13.39 in13.85 in13.39 in
    6 in10.63 in12.00 in10.63 in
    8 in7.72 in9.79 in7.15 in

    Weir widths in this table include the 0.2h contraction, while orifice widths do not, since the 0.6 coefficient already covers the entry loss. None include the code minimum or rounding to a whole inch.

    Up to its own height, a box flows as a weir, so heads at or below the box top give the same scupper size calculator width as an open channel.

    Where the parapet allows, make the box tall enough to stay a weir in any scupper size calculator check.

    California Plumbing Code Appendix D asks for an opening at least two times the design head, so a 3 in head calls for a 6 in tall box, above the general 4 in minimum.

    Millimeters, L/s and mm/hr Results

    A 200 m² roof at 100 mm/hr of rain sheds 5.56 L/s, and an overflow scupper at 2 times that flow with a 50 mm head needs 550 mm of clear width. In a metric scupper size calculator estimate, runoff is area times rainfall divided by 3,600.

    In metric, Q is the flow in m³/s, W the clear width in meters and h the head in meters. The 1.841 is the same weir coefficient as 3.0 in US units, so either system gives the same scupper.

    Roof AreaRainfallHeadFactorDesign FlowWidth With ContractionsCode Drain
    200 m²100 mm/hr50 mm1.00x5.56 L/s280 mm76 mm (240 mm wide)
    200 m²100 mm/hr50 mm2.00x11.11 L/s550 mm76 mm (240 mm wide)
    500 m²150 mm/hr75 mm2.00x41.67 L/s1,120 mm127 mm (399 mm wide)
    1,000 m²100 mm/hr50 mm2.00x55.56 L/s2,710 mm152 mm (479 mm wide)

    Metric scupper size calculator widths here round up to the next 10 mm. For scupper size in mm to inches, divide by 25.4, so the 550 mm overflow opening is 21 5/8 in and the 280 mm primary is 11 in.

    In any metric scupper size calculator result, a millimeter of head equals about 1 kg/m² of water. The 50 mm head above weighs 50 kg/m² on the roof, and over 200 m² that is 10,000 kg before any static head below the inlet.

    Asked When Sizing a Scupper

    These three questions come up most when a flat roof scupper is specified. Each answer uses a roof not already worked above, so the numbers add a new case.

    How are scuppers sized?

    Scuppers are sized on flow, then checked against the code width. First find the runoff from roof area and rainfall, then the width that passes it at the design head, then compare with the circumference of the roof drain the code requires.

    For a 3,600 sq ft roof at 3 in/hr, runoff is 112.2 GPM. At a 2 in head that needs 13.22 in, or 13.62 in with contractions, while the code drain for 3,600 sq ft at 3 in/hr is 4 in, setting a 12 9/16 in minimum.

    The larger figure wins in a scupper size calculator check, so build that scupper 14 in wide and at least 4 in high. The same steps size the scupper drain for each roof area, whether it serves as the primary outlet or the overflow.

    How do you calculate scupper width?

    Divide the design flow in GPM by 3.0 times the head in inches raised to the 1.5 power, then add 0.2 times the head for the side walls. Round the scupper size calculator result up to a whole inch you can build.

    For 249.4 GPM at a 2 in head, 2 to the 1.5 power is 2.828, so 249.4 divided by 8.485 gives 29.39 in. Adding 0.4 in for contractions makes 29.79 in, so the scupper is 30 in wide.

    How do I choose a scupper?

    Choose by role first, then by head. A primary scupper carries the design rain and sits at the roof surface, while an overflow scupper sits above the primary drain inlet and is commonly sized for twice the rain.

    Then settle the head the roof can carry. On a 5,000 sq ft roof at 4 in/hr, accepting 3 in of head instead of 2 in cuts the overflow from 50 in to 28 in but adds 5.2 psf of water across the roof.

    Use an open-top channel where the parapet allows it, since it never switches to orifice flow. A closed through-wall box should be at least twice the head in height and never under 4 in.