Solar panel size calculator for homes and off-grid batteries, sizing array kW, panel count, roof area, inverter, battery bank and payback from kWh use, a bill, a load or a battery.
Use the 12-month average from your bills. Pick your country for sun hours, or type your own.
Panel Size, Roof & Offset
Battery Backup & Inverter
Cost & Savings
The US 30% homeowner solar tax credit ended for systems installed after 2025.
Array Layout Diagram
Panels Needed by Wattage
| Panel Rating | Panels Needed | Array Size | Monthly Output |
|---|---|---|---|
| 100 W | 81 panels | 8.10 kW | 906.7 kWh |
| 200 W | 41 panels | 8.20 kW | 917.9 kWh |
| 300 W | 27 panels | 8.10 kW | 906.7 kWh |
| 350 W | 23 panels | 8.05 kW | 901.1 kWh |
| 400 W | 21 panels | 8.40 kW | 940.2 kWh |
| 450 W | 18 panels | 8.10 kW | 906.7 kWh |
| 500 W | 17 panels | 8.50 kW | 951.4 kWh |
| 550 W | 15 panels | 8.25 kW | 923.5 kWh |
| 600 W | 14 panels | 8.40 kW | 940.2 kWh |
Solar Panel Size Chart
| Cell Layout | Panel Size | Panel Area | Typical Rating |
|---|---|---|---|
| 60-cell | 64.6 × 39.1 in | 17.5 sq ft | 300-330 W |
| 120 half-cell | 69.1 × 40.9 in | 19.6 sq ft | 360-380 W |
| 108 half-cell | 67.8 × 44.6 in | 21.0 sq ft | 400-440 W |
| 144 half-cell | 89.7 × 44.6 in | 27.8 sq ft | 540-605 W |
Step-by-Step Math
Solar Panel Size Calculator Formula for a 900 kWh Home
In a solar panel size calculator estimate, a home using 900 kWh a month needs at least 8.04 kW of panels at 4.6 peak sun hours and 80% system efficiency. With 400 W panels that rounds up to 21 panels, an 8.40 kW array.
Daily energy, peak sun hours and system efficiency set every solar panel size calculator answer. Panel wattage only decides how many pieces the required kW is split into. The solar power calculation formula has three steps.
Emonth is your average monthly use in kWh and Eday is the daily average. Twelve months of bills make the steadiest solar panel size calculator input, since one hot summer or cold winter skews a single bill.
Pmin is the smallest array in kW. Hsun is peak sun hours per day, the hours of 1,000 W/m² sunlight your site averages. The Greek letter η is system efficiency as a decimal, 0.80 for 80%.
N is the panel count, always rounded up to a whole panel. Wpanel is the nameplate rating of one panel in watts, such as 400 W or 550 W.
For the 900 kWh home, 900 × 12 ÷ 365 = 29.59 kWh a day. Then 29.59 ÷ (4.6 × 0.80) = 8.04 kW, and 8,041 W ÷ 400 W = 20.1, so 21 panels. That array makes 30.9 kWh a day, or 104% of use.
NREL's PVWatts Version 5 Manual sets default system losses at 14% and inverter efficiency at 96%. Those multiply to 0.86 × 0.96 = 0.826.
Heat on a sunny roof cuts output further, so 80% is a realistic all-in efficiency for a solar panel size calculator estimate. A shaded or dusty array calls for a lower figure.
Dividing a monthly bill by 30, as many guides do, gives 30.0 kWh a day instead of 29.59. At 4.6 sun hours that is 8.15 kW, still 21 panels, so the shortcut rarely changes a solar panel size calculator result for a whole home.
Monthly kWh to Panel Count Across Sun Hours
A 1,000 kWh home needs 9.2 kW, or 23 panels of 400 W, at the US average of 4.6 sun hours. The same home in London needs 14.8 kW and 37 panels, because 2.8 sun hours make each panel produce 39% less.
Each cell below is a solar panel size calculator kWh result at 80% efficiency, showing the rounded-up array in kW and the number of 400 W panels behind it. Every column uses the annual average for that capital city.
| Monthly use | London 2.8 h | Berlin 2.9 h | New Delhi 4.0 h | Canberra 4.5 h | US average 4.6 h | Riyadh 5.1 h |
|---|---|---|---|---|---|---|
| 300 kWh | 4.80 kW / 12 | 4.40 kW / 11 | 3.20 kW / 8 | 2.80 kW / 7 | 2.80 kW / 7 | 2.80 kW / 7 |
| 500 kWh | 7.60 kW / 19 | 7.20 kW / 18 | 5.20 kW / 13 | 4.80 kW / 12 | 4.80 kW / 12 | 4.40 kW / 11 |
| 750 kWh | 11.20 kW / 28 | 10.80 kW / 27 | 8.00 kW / 20 | 7.20 kW / 18 | 6.80 kW / 17 | 6.40 kW / 16 |
| 1,000 kWh | 14.80 kW / 37 | 14.40 kW / 36 | 10.40 kW / 26 | 9.20 kW / 23 | 9.20 kW / 23 | 8.40 kW / 21 |
| 1,500 kWh | 22.40 kW / 56 | 21.60 kW / 54 | 15.60 kW / 39 | 14.00 kW / 35 | 13.60 kW / 34 | 12.40 kW / 31 |
| 2,000 kWh | 29.60 kW / 74 | 28.40 kW / 71 | 20.80 kW / 52 | 18.40 kW / 46 | 18.00 kW / 45 | 16.40 kW / 41 |
| W per monthly kWh | 14.68 W | 14.17 W | 10.27 W | 9.13 W | 8.93 W | 8.06 W |
The last row is the solar panel size per kWh. Multiply your monthly kWh by it for the minimum array in watts. At 4.6 hours, 900 kWh × 8.93 W = 8.04 kW, matching the worked example.
Annual averages hide winter. Below 3 sun hours, December output can fall far short of the yearly mean, so an off-grid cabin belongs in a solar panel size calculator run on its worst month, not on the yearly figure in this table.
For an Indian rooftop, the New Delhi column at 4.0 hours is the starting point for any solar panel size calculator India estimate. A 300-unit monthly bill needs 3.2 kW, or eight 400 W panels.
Output of 1 kW to 30 kW Solar Systems
A 1 kW array makes 3.2 kWh a day at 4 sun hours and 3.7 kWh at 4.6 hours. The popular rule that 1 kW gives 4 units a day only holds where sun hours reach 5.0 at 80% efficiency, so check it against a solar panel size calculator result for your sun.
| System | 400 W panels | 550 W panels | kWh/day at 2.8 h | kWh/day at 4.0 h | kWh/day at 4.6 h | kWh/month at 4.6 h |
|---|---|---|---|---|---|---|
| 1 kW | 3 | 2 | 2.2 | 3.2 | 3.7 | 112 |
| 1.5 kW | 4 | 3 | 3.4 | 4.8 | 5.5 | 168 |
| 2 kW | 5 | 4 | 4.5 | 6.4 | 7.4 | 224 |
| 3 kW | 8 | 6 | 6.7 | 9.6 | 11.0 | 336 |
| 5 kW | 13 | 10 | 11.2 | 16.0 | 18.4 | 560 |
| 10 kW | 25 | 19 | 22.4 | 32.0 | 36.8 | 1,119 |
| 12 kW | 30 | 22 | 26.9 | 38.4 | 44.2 | 1,343 |
| 30 kW | 75 | 55 | 67.2 | 96.0 | 110.4 | 3,358 |
A 10 kW system is enough for a house using up to about 1,100 kWh a month in 4.6-hour sun. In London's 2.8 hours the same array makes only 681 kWh a month, so any solar panel size calculator answer to that question depends on sun as much as on kW.
A 12 kW array covers about 1,170 to 1,340 kWh a month at 4.0 to 4.6 hours. A 30 kW array makes 2,900 to 3,360 kWh a month, which fits a large all-electric home with EV charging or a small business.
One 400 W panel is 0.4 kW and makes 1.47 kWh a day at 4.6 hours. A 1 kW array cannot be built exactly from 400 W panels, so it becomes three panels and 1.2 kW, or two 550 W panels and 1.1 kW.
A 1.5 kW array makes about 5.5 kWh a day at 4.6 hours, or 168 kWh a month. A 3 kW array of eight 400 W panels covers about 168 sq ft (15.6 m²) of roof in a solar panel size calculator layout.
Panel Dimensions, Sizes and Wattage Chart
The common 108 half-cell home panel, rated 400-440 W, measures 67.8 × 44.6 in (1722 × 1134 mm) and cover 21.0 sq ft (1.95 m²). Jinko's Tiger Neo 54HL4 datasheet lists that frame with 108 half-cells at 22.0 kg (48.5 lb).
| Cell layout | Size (in) | Size (mm) | Area | Typical rating | Roof per kW at lower rating |
|---|---|---|---|---|---|
| 60-cell | 64.6 × 39.1 | 1640 × 992 | 17.5 sq ft (1.63 m²) | 300-330 W | 58.4 sq ft (5.42 m²) |
| 120 half-cell | 69.1 × 40.9 | 1755 × 1038 | 19.6 sq ft (1.82 m²) | 360-380 W | 54.5 sq ft (5.06 m²) |
| 108 half-cell | 67.8 × 44.6 | 1722 × 1134 | 21.0 sq ft (1.95 m²) | 400-440 W | 52.5 sq ft (4.88 m²) |
| 144 half-cell | 89.7 × 44.6 | 2278 × 1134 | 27.8 sq ft (2.58 m²) | 540-605 W | 51.5 sq ft (4.78 m²) |
In a solar panel size calculator comparison, bigger panels barely save roof. A 540 W panel needs 51.5 sq ft per kW against 52.5 sq ft for a 400 W panel, under 2% less. The real gain is fewer pieces to mount and wire, not a smaller array.
Check a spec sheet before its figures go into a solar panel size calculator. Watts ÷ (m² × 1,000) gives 20.5% for 400 W on 1.95 m² and 22.5% for 440 W. Above 25%, a figure is a typo.
Switching a solar panel size calculator in inches to metric changes only the labels, not the footprint. Convert with 25.4 mm per inch, then 144 sq in per sq ft or 1,000,000 mm² per m².
Roof Space for the Array and the 1,000 sq ft Question
Twenty-one panels of 67.8 × 44.6 in cover 441 sq ft (41.0 m²). Set 7 across and 3 deep in portrait, the block measures 26 ft wide by 16 ft 11 in deep before any gaps between panels.
Those figures are panel footprint only. Fire-code roof pathways, ridge and edge setbacks, vents and skylights all take space, so plan a wider margin than the bare count on any rooftop solar panel calculator estimate.
| Clear roof area | 108 half-cell panels that fit | Array at 400 W | 144 half-cell panels that fit | Array at 540 W |
|---|---|---|---|---|
| 300 sq ft (27.9 m²) | 14 | 5.6 kW | 10 | 5.4 kW |
| 500 sq ft (46.5 m²) | 23 | 9.2 kW | 17 | 9.18 kW |
| 1,000 sq ft (92.9 m²) | 47 | 18.8 kW | 35 | 18.9 kW |
| 1,500 sq ft (139.4 m²) | 71 | 28.4 kW | 53 | 28.62 kW |
A clear 1,000 sq ft roof holds 47 standard panels, an 18.8 kW array at 400 W. When 1,000 sq ft is the floor area of the house, the kWh on the bills belong in the solar panel size calculator instead, because floor area does not set use.
A 100 m² flat roof holds 51 of the 1722 × 1134 mm panels on footprint alone. Rows on a flat roof are tilted and spaced to avoid shading each other, so trim that count before a solar panel size calculator figure becomes a quote.
Charging a 100Ah or 200Ah Battery From Solar
A 12 V 200Ah lithium battery used to 80% needs 1,920 Wh back each day. That takes about 600 W of panels at 4 sun hours, or three 200 W panels. A 12 V 100Ah battery at 80% needs 300 W.
Ah and V are the battery's rated capacity and voltage. DoD is the share you drain before recharging, as a decimal. The letter t is the days you allow to refill it, and Pmin comes out in watts.
| 12 V battery | Depth used | Wh to replace | Minimum at 4.0 h | Minimum at 4.6 h | 200 W panels at 4.0 h | Charge current |
|---|---|---|---|---|---|---|
| 100Ah | 80% | 960 Wh | 300 W | 261 W | 2 (400 W) | 33.3 A |
| 100Ah | 50% | 600 Wh | 188 W | 163 W | 1 (200 W) | 16.7 A |
| 200Ah | 80% | 1,920 Wh | 600 W | 522 W | 3 (600 W) | 50.0 A |
| 200Ah | 50% | 1,200 Wh | 375 W | 326 W | 2 (400 W) | 33.3 A |
Charge current is array watts divided by battery volts, which sets the charge controller rating. Three 200 W panels on a 200Ah bank push 50 A, a 0.25C rate. A 400 W panel on a 100Ah bank pushes 0.33C, so check the maker's charge limit.
Allowing two days to refill halves the array, so the 200Ah battery at 80% needs only 300 W at 4 sun hours. For a weekend camping setup, that is the cheapest solar panel size calculator lever.
The Battery Charge Time Calculator turns that charge current into hours. The Battery Size Calculator works the other way, from your loads to the Ah you need.
Battery Bank and Inverter Sizing for 3 kW to 10 kW
One day of storage for a 3 kW array's output is 13.8 kWh at 80% depth of discharge, or three 48 V 100Ah batteries. A 10 kW array's daily output needs a 46.0 kWh bank, which is ten of the same batteries.
Ebatt is the bank size in kWh, Eday is daily use or output in kWh, and D is backup days. Divide Ebatt × 1,000 by bank voltage for amp-hours.
| Array | kWh/day at 4.6 h | Bank for 1 day at 80% | Ah at 48 V | 48 V 100Ah units | Charge current at 48 V | Charge current at 12 V |
|---|---|---|---|---|---|---|
| 3 kW | 11.0 | 13.8 kWh | 288 Ah | 3 | 63 A | 250 A |
| 5 kW | 18.4 | 23.0 kWh | 479 Ah | 5 | 104 A | 417 A |
| 10 kW | 36.8 | 46.0 kWh | 958 Ah | 10 | 208 A | 833 A |
In any solar panel size calculator plan, a 12 V bank is the wrong choice above a few hundred watts. A 3 kW array charging at 12 V pushes 250 A, which needs several controllers and very heavy cable. At 48 V the same power flows at 63 A.
In a solar panel inverter size calculator plan, a grid-tied inverter is array kW divided by the DC-to-AC ratio. The 8.40 kW array needs a 7.0 kW inverter at a 1.2 ratio, or 7.64 kW at the 1.1 default used in PVWatts.
A higher ratio clips a little midday output in exchange for a cheaper inverter that runs nearer full load more of the day. An off-grid inverter is a different case, sized on peak load and motor surge rather than array kW.
Planning hours of backup rather than days fits the UPS Runtime Calculator, and charge amps follow from the Current Calculator.
Running an AC on 1, 2, 3, 5 or 10 kW of Solar
A 1.5-ton AC with an EER of 11 draws about 1,636 W. A 2 kW array tops out near 1.6 kW at noon, just short of that, while a 3 kW array runs one with about 0.76 kW to spare at peak sun.
PAC is the running draw in watts and T is the cooling capacity in tons, since one ton is 12,000 BTU/h. EER is the label rating in BTU/Wh; a rating in W/W converts to BTU/Wh when multiplied by 3.412.
The label EER moves a solar panel size calculator answer for an AC more than the tonnage rounding does. The same 1.5-ton unit draws 2,000 W at EER 9 and 1,385 W at EER 13.
| AC size | Draw at EER 9 | Draw at EER 11 | Draw at EER 13 |
|---|---|---|---|
| 1 ton | 1,333 W | 1,091 W | 923 W |
| 1.5 ton | 2,000 W | 1,636 W | 1,385 W |
| 2 ton | 2,667 W | 2,182 W | 1,846 W |
The next table pairs each array with a 1.5-ton AC at EER 11, using 80% efficiency. Noon output is the most the panels give at once, and daily energy sets how many hours of cooling the sun pays for.
| Array | Noon output at 80% | kWh/day at 4.0 h | kWh/day at 4.6 h | AC hours at 4.0 h | 1.5-ton ACs at noon |
|---|---|---|---|---|---|
| 1 kW | 0.8 kW | 3.2 | 3.7 | 2.0 | 0 |
| 2 kW | 1.6 kW | 6.4 | 7.4 | 3.9 | 0 |
| 3 kW | 2.4 kW | 9.6 | 11.0 | 5.9 | 1 |
| 5 kW | 4.0 kW | 16.0 | 18.4 | 9.8 | 2 |
| 10 kW | 8.0 kW | 32.0 | 36.8 | 19.6 | 4 |
A 1.5-ton AC cannot run on 1 kW of solar alone, since 0.8 kW at noon is half its draw. On 2 kW it runs from the panels at noon only if its EER is about 11.3 or higher, so a 13-EER unit fits and an 11-EER unit does not.
Two 1.5-ton ACs on 3 kW need 3.27 kW against 2.4 kW of noon output, so they run only with grid support. On 5 kW, two run through midday with about 0.73 kW to spare, and 10 kW carries four at noon.
Carrying one 1.5-ton AC for 8 hours takes 13.1 kWh a day, the load figure that goes into a solar panel size calculator. At 4.0 sun hours that is 4.09 kW minimum, or eleven 400 W panels.
Daytime cooling can run straight from the panels. Peak sun hours are not daylight hours, so only the cooling after sunset or before the morning sun needs battery storage.
Each hour of running uses about 1.64 kWh, so the AC bill for one hour is 1.64 times your tariff per unit. At $0.17 per kWh that comes to about $0.28 an hour.
The Electricity Cost Calculator prices those hours at your tariff, and the Energy Consumption Calculator totals a full day of appliances before you size the array.
Cost and Payback at Your Price per Watt
Every solar panel size calculator cost figure is array watts times price per watt. At $2.80 per watt an 8.4 kW array costs $23,520, a 3 kW array $8,400 and a 1 kW array $2,800. Payback does not change with system size.
Tpayback is simple payback in years, cW is installed price per watt and r is your electricity rate per kWh. Array size cancels out, so a bigger solar panel size calculator result never shortens payback by itself.
| Rate per kWh | 3.0 sun hours | 4.0 sun hours | 4.6 sun hours | 5.0 sun hours |
|---|---|---|---|---|
| $0.12 | 26.6 years | 20.0 years | 17.4 years | 16.0 years |
| $0.17 | 18.8 years | 14.1 years | 12.3 years | 11.3 years |
| $0.25 | 12.8 years | 9.6 years | 8.3 years | 7.7 years |
| $0.35 | 9.1 years | 6.8 years | 6.0 years | 5.5 years |
All rows assume $2.80 per watt and 80% efficiency, and value every solar kWh at the full retail rate, the usual solar panel size calculator assumption. Export credits below retail stretch these years, and batteries are an extra cost on top.
The ratio is the same in any currency. A quote in rupees per watt against a tariff in rupees per unit, or euros against euros, gives the same years for the same sun, so local prices drop straight into a solar panel size calculator in any country.
US buyers no longer get the 30% federal credit on home systems. The IRS Residential Clean Energy Credit page lists it as unavailable for property placed in service after December 31, 2025.
Sizing Answers on Panels, Batteries and Risks
Each answer below uses 80% efficiency and the sun hours it names, the same inputs as every solar panel size calculator table above, so the figures compare directly with the tables.
Can you run 2 solar panels to 1 battery?
Two panels can charge one battery through a single charge controller. Two 200 W panels in parallel on a 12 V battery push about 33 A. They refill a 100Ah battery used to 80% in 3.0 peak sun hours.
Wired in series, the same two panels double the voltage and keep the current, which suits an MPPT controller rated for their combined open-circuit voltage. Parallel wiring keeps the voltage and doubles the current.
How many inverters per solar panel?
A string inverter serves the whole array, so the 21 panels of the 900 kWh solar panel size calculator example share one 7.0 kW unit at a 1.2 DC-to-AC ratio. With microinverters, each panel gets its own, so the same array uses 21 of them.
How many watts to run a 3000 sq ft house?
Floor area does not set the watts; the bills do. A 3,000 sq ft home averaging 1,500 kWh a month uses 49.3 kWh a day, which needs 13.4 kW at 4.6 sun hours, or 34 panels of 400 W.
If the same house averages 750 kWh a month, the array drops to 6.8 kW and 17 panels. A year of bills is the right solar panel size calculator input, and it pins down the solar panel size needed for the house.
Can I run my AC all day with solar?
Only with a battery or the grid behind it. A 1.5-ton AC at EER 11 running 12 hours uses 19.6 kWh, so it needs 5.34 kW of panels at 4.6 sun hours, or fourteen 400 W panels.
If six of those hours fall after sunset, they draw 9.8 kWh from storage. At 80% depth of discharge that takes a 12.3 kWh battery bank on top of the array, which is what makes all-day solar cooling costly.
What is the biggest risk of solar panels?
For sizing, the biggest risk is a shortfall in low sun that a yearly-average solar panel size calculator figure hides. An 8.4 kW array built for 4.6 hours makes 30.9 kWh on an average day but 18.8 kWh on a 2.8-hour winter day, 39% less.
The other drawbacks are just as measurable. Output is zero at night, 21 panels need 441 sq ft of clear roof, and at $0.17 per kWh the money takes about 12 years to come back.